2.6 Connection instructions for Phoenix terminal blocks

To connect the Phoenix terminal blocks, always use the following procedure:
strip the jacket 20mm
-
-
strip the wires 7 mm
DO NOT pre tin the wires
-
cover the ground wire with a heat shrink sleeving
-
-
put the wire up to the plastic sleeve in the terminal block
use a small flathead screwdriver to firmly close the contact
-
make a strain relief so no stain is on the connection
-
for suitable wire thickness, please refer to the table below
-
ENGINEERHARDWAREMANUAL1.1[1].doc
13