When Con@ctivity is active, the
cooker hood always operates in
automatic mode (see "Before using for
the first time" – "Setting up
Con@ctivity").
If you wish to manually operate the
cooker hood, see "Operation (Manual
mode)" – "Cooking without
Con@ctivity".
Cooking with Con@ctivity
(Automatic mode)
 Switch a cooking zone on at the
desired power level.
The hob lighting will come on.
After a few seconds the fan will come
on, first at power level 2, then it will
switch immediately to power level 1.
The cooker hood selects the fan power
level automatically during cooking.
This is determined by the total output of
the hob, i.e. the number of cooking
zones in operation and the power levels
selected.
If you select a higher power level or are
using several cooking zones, the cooker
hood will switch to a higher fan power
level.
When you reduce the power level or the
number of cooking zones on the hob,
the fan power level is also reduced.

Operation (Automatic mode)

Examples for power levels 1 to B
Reaction time
The cooker hood reacts with a slight
delay because altering the power level
on the hob does not immediately result
in a reduction or increase in cooking
vapours.
Because the hob transmits the
information to the cooker hood at
intervals, this can also cause delays.
The reaction can vary from a few
seconds to a couple of minutes.