ALIGNM ENT
OF
TRANSMITTER
D RIVER AND RECEIVER F RONT END STAGE
( 1 )
Connect a dummy load/wattme ter to the
rear p anel ANT j ack.
( 2)
Set the RF/ AF gain controls fully clockwise ,
s e t the MOD E switch to F SK , and set TC 2 s o 6
t o the 1 /3 c apacitance setting, as shown in
Fig. l .
( 3 )
Set the B AND switch to l OD , se t the m ain
tuning dial for a reading of 3 0 .000 MHz, and
set the PRE S E LECT control t o the u p p er end
of the 1 0 m eter band ( fully clockwise) . Set
the LOAD c ontrol to 3 , and dip the P LATE
CONT ROL while tuning.
( 4)
Set the CARR control to the 1 2 o 'clock
p o sition. Set the VOX GAIN c ontrol to MOX
( for not m o re th an 1 0 se conds) , an d carefully
T
T
2 and
a djust
3
for m a ximu m I C reading on
the m e t er. Be sure that the bonding agent has
b een remov e d before you adjust the c ores.
( 5)
While r eceiving, set the MARK E R switch O N ,
a n d tune to t h e c alibrator signal. Adjust T i
for m aximum S-m eter d e flection.
(6)
Now set the B AND switch to l OA, set the
VFO for a display frequency o f 2 8 .000 MHz ,
a n d peak the PRESELECT control for m axi­
mum PO
while tuning.
c ontrol for minimu m I C indication . Now set
the VOX G AI N switch to MOX, and adjust
TC 2 s 0 6
maximum
m e te r ( FSK mode, still) .
(7)
S e t the MARKER switch ON, and tune t o the
c alibrator signal. Peak T C 2 4 0 6 for m axim u m
S-me ter deflection .
( 8)
A s there m ay be some interaction o f a djust­
m e n ts, please repeat steps ( 3 ) through ( 7 ) .
( 9 )
A djust
the
fin al
as described on p age 48 .
( 1 0) Again repeat steps ( 3 ) through ( 8) .
B R OW N
� �
M A X
1 /3
Fig.
MIXER/
Dip the P LATE
I C
indication on the
amp lifier n eu traliz ation,
M I N
1
( 1 1 ) Now you are ready t o align the other bands .
Set the B AND switch to 1 5 , set th e m ain
tuning dial for a reading of 2 1 .000 MHz, and
set the P RESELECT c ontrol at 8 . 6 on its
scale . Dip the P LATE control for minimum
I C indication while tu ning. Set the VOX
GAI N control to MOX, and adjust TC2 6 o s
and TC 2 s' o s for maximum PO indication on
the me ter. On receive , tune in the MARK E R
signal, an d adjust T C 2 4 o s for maximum S ­
m e ter deflection.
( 1 2) Set the B AND switch to 20, set the VFO for
a frequncy o f 1 4. 000 MHz, and set th e P RE­
SELECT c ontrol to 7 . 2 on its scal e . Dip the
P LATE con trol for m inimum IC indication
while tuning . Set the VOX GAIN c ontrol to
MOX, and adjust TC 2 6 04 for m aximum PO
in dication on the m e ter. On receiv e , tune in
the MARKER signal, and adjust T C 2 4 0 4 for
m aximum S-m e ter deflection.
T
2 4 0 1
T
2 4 0 2
T
2 s o 2
T
2 s o 1
- 49 -