Summary of Contents for Tohken TFIR-31DM Series

  • Page 1 TFIR-31DMSeries Compact Fixed Mount Image Reader (Linear / 2D Scanner) OPERATION MANUAL TOHKEN CO.,LTD. 2nd Edition December 8, 2009...
  • Page 2 [Memorandum]...
  • Page 3: Safety Notice

    Introduction Thank you for purchasing this product. This manual explains the features of this product, operation, system configuration, specifications, etc. In order to use the product properly, please read this manual carefully. When there is any problem during normal use, please document it carefully to be reproduced by our support team.
  • Page 4: Handling With Care

    CAUTION Please do not use AC adapters other than the recommend AC power adaptor which is described in the “unpacking the carton” section. Failure to do so might affect the performance of the unit. If the voltage or polarity used is different from the specification, it might cause product failure and could be the cause of an accident.
  • Page 5: Unpacking The Product

    CAUTION When stain or dust is stuck on the reading window, please follow the following steps to clean it: - Wipe off stain lightly with cloth or swab (wet with alcohol) - Wipe off again with the dry clothes. DON NOT Wipe off with any chemicals. CAUTION This is a high-precision optical device.
  • Page 6: Table Of Contents

    TABLE OF CONTENTS INTRODUCTION .......................... I SAFETY NOTICE ......................... I HANDLING WITH CARE ......................II UNPACKING THE PRODUCT ....................III 1.GETTING STARTED .........................1 1.1 S ......................2 UPPORTED BARCODES 1.2 P ........................2 ICTURE TAKING 1.3 O .....................3 RDERING INFORMATION 1.4 H ........................4 OW IT WORKS 2.
  • Page 7 3.9.3 Serial Command ......................30 3.9.4 Flow chart ........................32 4. SERIAL COMMAND.......................33 4.1 T ....................33 RANSMISSION ETTINGS 4.2 R ......................35 EADING YMBOLS 4.3 R ) ......42 EADING PERATION ORMAL PERATION DJUSTMENT DIAGNOSIS 4.4 C ......................44 AMERA ONTROL 4.5 P .....................45 RESET ETTING 4.6 R .......................45...
  • Page 8: Getting Started

    1.Getting started The TFIR-31DM is a compact high performance two-dimensional scanner that can read all traditional 1D and 2D symbologies. Thanks to the special illumination, TFIR-31DM is suitable for Direct Parts Marking application like laser marking on PCB and metal surface. Leading the industry in cost-effectiveness, imaging performance and low power consumption, the TFIR-31DM provides OEMs and Machine building companies with 1D &...
  • Page 9: Supported Barcodes

    1.1 Supported barcodes The unit can read the following symbols: 1D bar codes: Code39 Code128 Codabar ITF (interleaved 2 of 5) JAN/EAN/UPC Code93 2D codes: Data Matrix (ECC200) QR Code Micro QR PDF 417 Micro PDF Mxi Code Composite 1.2 Picture taking The TFIR-31DM can take 24bit color and Grey scale pictures for example signature capture.
  • Page 10: Ordering Information

    1.3 Ordering information TFIR-31DM U F - X 1. Model name 2. Interface If “U” follows “TFIR-31DM” , the scanner has USB interface. And if there is no “U”, its interface is RS232C. 3. “F” or “S” These are the position of the reading window. “F” means FRONT and “S” means SIDE.
  • Page 11: How It Works

    1.4 How it works • Status LED The status LED lights up either GREEN or RED depending on the operation: - GREEN light indicates the completion of successful decoding of a symbol. - Flashing GREEN light indicates the image data transmission in progress. - RED light indicates the failure of decoding.
  • Page 12: Operation

    2. Operation 2.1 Basic Operation (1) When the power is turned on, LED A, B, C and D turn on simultaneously. After all of them turn off, only LED B start blinking. (2) Then two aiming beam indicate where the unit is seeing, where is the center of field of view. (3) When SYNC is on, the TFIR captures an image and starts decoding the symbol.
  • Page 13 The following are the functions of four LED indicators Start up of the unit Under the normal operation In the setup mode A (red) ON for 1 second ON with DOUT command Please see section 11 B (green) Always blinking Always blinking (indicating “Ready”) Please see section 11 C (green)
  • Page 14: Reading Operation

    2.2 Reading Operation The unit has various types of mode operations. Reading operation means capture image and decode the symbol. Operation Mode Command Function Normal Mode SYNCMODE=0 Single SYNC input performs single decode. After trigger input, it starts setting interval time Reading Time out Mode SYNCMODE=1 duration setting command TOTALLIM=.
  • Page 15: Transmitting Image Data

    -The function for transmitting a serial command that’s required for setup -The function for receiving the barcode data from this unit Note: The driver can be downloaded from our secure web site. URL: http://www.tohken.co.jp/ - -...
  • Page 16: Description Of Reading Operation

    3. Description of reading operation DELAY::The time from getting SYNC ON to reading CHATT: The time for eliminating the chattering IMAGE: The time for capturing an image DECODE: The decoding time DECODELIM: The maximum time for decoding GOOUT: The time for outputting GO signal NGOUT: The time for outputting NG signal SERIAL: The time for outputting data through serial interface 3.1 Normal Mode...
  • Page 17 Fig. 3.1-2 Hard Trigger, Read OK, Data Transmit timing; After decoding SYNC DELAY image1 IMAGE decode1 DECODE DECODELIM SERIAL GO-OUT GOOUT CHATT Fig. 3.1-3 Hard Trigger, Read NG, Data Transmit timing ; After decoding SYNC DELAY image1 IMAGE decode1 DECODE DECODELIM SERIAL NG-OUT...
  • Page 18 Fig. 3.1-4 Hard Trigger, Read NG, Data Transmit timing; Judged as NG SYNC DELAY image1 IMAGE decode1 DECODE DECODELIM SERIAL NG-OUT NGOUT CHATT - -...
  • Page 19: Read Time Out Mode

    3.2 Read Time Out Mode After trigger input, the unit starts the timer for setting interval duration (setting command TOTALLIM=). When the reading operation is failed, an error code transmits after the end of the reading time set up by TOTALLIM. Fig.
  • Page 20 Fig. 3.2-3 Hard Trigger, Read OK, Data Transmit: After decoding, Judge Output: right after decoding SYNC DELAY image1 image2 IMAGE decode1 decode2 DECODE DECODELIM DECODELIM SERIAL TOTALLIM GOOUT CHATT Fig. 3.2-4 Hard Trigger, Read OK, Data Transmit: After Sync OFF, Judge Output: with reading result output DELAY image1...
  • Page 21 Fig. 3.2-5 Soft Trigger, Read NG, Data Transmit: After Sync OFF or right after decoding, Judge Output: with reading result output Successful decoding must be ended within the specified TOTALLIM time. SYNC DELAY image1 image2 IMAGE decode1 decode2 DECODE DECODELIM DECODELIM SERIAL TOTALLIM...
  • Page 22: External Sync Mode

    3.3 External SYNC mode While SYNC signal is coming in through digital input (SYNC input), the unit tries to read. Fig. 3.3-1 Hard Trigger, Read OK, Data Transmit: After Sync OFF, Judge Output: with reading result output SYNC DELAY image1 image2 IMAGE decode1...
  • Page 23 Fig. 3.3-3 Hard Trigger, Read NG, Data Transmit: After Sync OFF or right after decoding, Judge Output: with reading result output SYNC DELAY image1 image2 IMAGE decode1 decode2 DECODE DECODELIM DECODELIM SERIAL NGOUT CHATT CHATT - -...
  • Page 24: Continuous Reading Mode

    3.4 Continuous Reading Mode Sending the continuous read command “continue“ to the unit starts the next operation. Send the stop command “stop” to end operation. Use this mode for the camera adjustment. 3.5 Test Mode To enter this mode, (TEST=1) command should be transmitted to the unit using serial interface and reading is started, the unit will start reading the symbol for 10 times (default).
  • Page 25: Swing Mode

    3.6 Swing Mode The unit will enter this mode by sending “AGC=S” command to the unit. In this mode, image capture and decoding are performed based on a configuration that is previously stored for AGC and shutter speed for respective image capture. In this mode, Up to eight shutter speed, AGC values and image preprocessing can be stored.
  • Page 26: Preset Mode

    3.7 Preset Mode If only particular data is needed, the data should be memorized in TFIR in advance (Preset) so that TFIR outputs only the data when it decodes symbols. e.g. Data Type of the symbol Symbol A ABCDEFG Data Matrix Symbol B ABCDEFG Code39...
  • Page 27 WSETS[CR] Save the setting in non-volatile memory )Example 1 Make only ”12345” valid match 12345 not match 1234 123456 not match 012345 not match PREM=2[CR] SET=PRED12345[CR] : to set characters used for comparing (12345:data character) SET=PREN5[CR] : Digits used for comparing(5 digits) WSETS[CR] : Saving the setting in non-volatile memory )Example 2 Valid when former 4 digits is “ABCD”...
  • Page 28: 3)Output The Preset Status

    SET=PRED??ALFA????[CR]: to set characters used for comparing (??ALFA????:data character) SET=PREN10[CR] : Digits used for comparing(10 digits) WSETS[CR] : Saving the setting in non-volatile memory 3)Output the Preset status ?pre[CR] Output the Preset status (example of output) PREM=0 (0:non 1:power on 2:saved) PRESET LENGTH:41 DATA(HEX): 31 32 33 3F 3F 3F 3F 3F 3F 3F...
  • Page 29: Description Of Diagnosis Mode

    3.8 Description of Diagnosis mode 1) Confirmation for Output of Reading statistics and Decoding Time [Reading OK and NG Count Number Output Example] *** TOTAL *** 1:OK 99/SYNC 100 NG 1.00%:OK 99.00% [Reading Ok and Ng Decoding Time Output Example] *** DECODE TIME *** OK: min(0118ms),max(0124ms),ave(0120ms) NG: min(0148ms),max(0148ms),ave(0148ms)
  • Page 30: Output Of Total Decoding Time

    3) Output of total decoding time This unit can output, in addition to the decoded data, the total reading time (time from SYNC ON to an OK data output) as well as the number of pictures acquired from SYNC ON to the successful decoding.
  • Page 31: Contrast Information

    5) Contrast Information This is used to enable or disable adding image contrast information. It output image contrast information after last captured and decoded image. i) In case of OK reading The contrast information in symbol recognition area is transmitted. Finding rectangular coordinate from the minimum and maximum of the square coordinates of a symbol is calculated from the area of contrast information.
  • Page 32: Output The Coordinate Of The Symbol

    7) Output the coordinate of the symbol The setting to output the information of the symbol’s position in the field of view is available. There are three types of output, coordinate of the center and/or the coordinate of four apexes. 1) The center When TFIR reads a symbol, the coordinate of the symbol’s center will be outputted.
  • Page 33 2) Four apexes When TFIR reads a symbol, the coordinate of the symbol’s four apexes will be outputted. The origin (000, 000) is the lest-top edge of field of view. (Exsample) 100000000990703(+269,+011)(+455,+086)(+386,+270)(+198,+199) (Format) Header + Data + (A1) + (A2) + (A3) + (A4) + Terminator A1 –...
  • Page 34 3) The center and four apexes When TFIR reads a symbol, the coordinate of the symbol’s four apexes will be outputted. The origin for the center is the center of field of view, and for four apexes is left-top edge of field of view.
  • Page 35: Auto Detection Mode

    3.9 Auto detection mode 3.9.1 Overview By using this mode, TFIR-31DM can read and decode symbols automatically. TFIR-31DM detects changes of image in its field of view, like change of environmental brightness, motion of objects. When there is such a change, TFIR-31DM starts to capture an image and tries to decode.
  • Page 36: How To Use

    3.9.2 How to use To put TFIR-31DM in the auto detection mode, please follow one of the following methods: Send the serial command "SYNCMODE=3<CR>" to the scanner. Read the corresponding barcode from the configuration barcode set. To exit the auto detection mode, please follow one of the following methods: Send the serial command "SYNCMODE=0 (or 1 or 2)<CR>"...
  • Page 37: Serial Command

    3.9.3 Serial Command Enable/Disable Auto-detection mode Enable : SYNCMODE=3 Disable : SYNCMODE=0 or 1 or 2 Timeout: Label disappear (LFMOVELIM) After detecting an object, the unit starts waiting for the object go out form the field of view. The limit time for the waiting can be configured. If the limit time is short, please remove the object immediately.
  • Page 38 Prohibit to read the same data (LFVERIFY) If this parameter is enabled, the unit does not read barcodes which have identical data within the specified limit time. vii) Limit time for LFVERIFY (LFVWAIT) Limit time for LFVERIFY. viii) The list of serial commands for Auto-detection (HELPLF) Display the list of serial commands for Auto-detection.
  • Page 39: Flow Chart

    3.9.4 Flow chart Aiming beam: Blinking Aiming beam: Blinking Standby Standby Make an object with Make an object with barcodes gone into barcodes gone into TFIR-31’s field of TFIR-31’s field of view view “Label in” “Label in” Detected? Detected? No: Timeout No: Timeout Within Within...
  • Page 40: Serial Command

    4. Serial Command 4.1 Transmission Settings Default Setting:* Item Serial Command Contents Baud Rate BAUD=1200 Baud Rate Setting 1200bps BAUD=2400 Baud Rate Setting 2400bps BAUD=4800 Baud Rate Setting 4800bps BAUD=9600 Baud Rate Setting 9600bps(*) BAUD=19200 Baud Rate Setting 19200bps BAUD=38400 Baud Rate Setting 38400bps BAUD=57600...
  • Page 41 Item Serial Command Contents Separator SEPA=0 Separator Setting, Non SEPA=1 Separator Setting, & SEPA=2 Separator Setting, , SEPA=3 Separator Setting, [FS] ( 1C hex ) (*) SEPA=4 Separator Setting, [GS] ( 1D hex ) SEPA=5 Separator Setting, [SP] ( 20 hex ) Prefix PREFIX=a Set a character for prefix...
  • Page 42: Reading Symbols

    4.2 Reading Symbols Item Command Contents Common SET=#M1 Disable reading of all 1-D and 2-D Symbol System Setting SET=#M0 Enable reading of all 1-D and 2-D Symbol System SYMHEAD=#a Set symbol header for all symbol types. =#a,¥bb a=0; Disable (*), a=1; Enable =#a,c bb;...
  • Page 43 Item Command Contents Code128 SET=CM0 Disable reading of Code128(*) SET=CM1 Enable reading of Code128 Set Code128 reading range from Min. digits (b digits) to DIGIT=Cb,c Max. digits(c digits) EDIT=Cb,c Edit Transmit specific “b” digits through “c” digits of Code128 EAN-128 SET=eM0 Disable reading of EAN128(*) SET=eM1...
  • Page 44 Item Command Contents UPC/EAN/JAN SET=EM0 Disable reading UPC/EAN/JAN(*) SET=EM1 Enable reading UPC/EAN/JAN Enable Check Sum Transmitting is set for Standard JAN/EAN JE13SUM=0 (Include Add-on) (*) Disable Check Sum Transmitting is set for Standard JAN/EAN JE13SUM=1 (Include Add-on) Enable Check Sum Transmitting is set for Shortened JE8SUM=0 JAN/EAN(Include Add-on) (*) Disable Check Sum Transmitting is set for Shortened...
  • Page 45 Item Command Contents CODABAR SET=FM0 Disable Reading CODABAR(*) SET=FM1 Read CODABAR, Disable C/D Check SET=FM2 Read CODABAR , Enable C/D Check, C/D Transmit SET=FM3 Read CODABAR , Enable C/D Check, No C/D Transmit CODASS=0 Enable Transmit Start/Stop Code by small letter of CODABAR CODASS=1 Enable Transmit Start/Stop Code by Capital l letter of CODABAR(*) CODACS=0...
  • Page 46 Item Command Contents MaxiCode SET=UM00 Disable reading of MaxiCode(*) SET=UM01 Enable reading of MaxiCode Mode0 SET=UM02 Enable reading of MaxiCode Mode1 SET=UM04 Enable reading of MaxiCode Mode2 SET=UM08 Enable reading of MaxiCode Mode3 SET=UM10 Enable reading of MaxiCode Mode4 SET=UM20 Enable reading of MaxiCode Mode5 SET=UM3F Enable reading of MaxiCode Mode 0 through 5...
  • Page 47 Item Command Contents SET=eM00-RSS Disable reading of RSS(*) SET=eM01-RSS Enable reading of RSS Expanded SET=eM02-RSS Enable reading of RSS Expanded Stacked SET=eM04-RSS Enable reading of RSS Limited SET=eM08-RSS Enable reading of RSS-14 and RSS-14 Truncated Enable reading of RSS-14 Stacked and RSS-14 Stacked SET=eM10-RSS Omnidirectional SET=eM1F-RSS...
  • Page 48 Item Command Contents Common DECODELIM=a Set decoding limit time , a=100-3000,unit[ms], every 100[ms] Setting TOTALLIM=a Read limit time when SYNCMODE=1, a=100-30000,unit[ms] MIRROR=0 Reading performed Normal Label (Not Mirror Image) (*) MIRROR=1 Reading performed Mirror Image Label Reading performed Normal Label, then in case of No read occurred, try MIRROR=2 to read Mirror Image.
  • Page 49: Reading Operation (Normal Operation, Adjustment, Diagnosis)

    4.3 Reading Operation (Normal Operation, Adjustment, diagnosis) Item Command Contents Reading Start Reading (SYNC ON) The message to send in event of read error BR=a a=0; None, a=1; “BR”, BR=2; “ERROR”, BR=3; “?” LABELS=a Number of labels to read a=1-4 label(s) Normal SYNCMODE= a=0;...
  • Page 50 Auto Detection mode Item Command Contents Wait to start the next detection LFMOVELIM=_ 0:50 1:100 2:200 3:500 4:1000 5:2000 6:3000 7:5000 ignored time (ms) Time for 1~40 : 0.5 (s)~10 (s) LFDECLIM=_ LFMOVELIM [Step: 0.5(s)] Aimer setting during auto LFPOINTER=_ 0: Off 1: Blink detection mode Sensitivity...
  • Page 51: Camera Control

    4.4 Camera Control Item Command Contents AGC=a AGC value transmitted to the camera a = 11-255 AGC=D Fixed AGC value transmitted to the camera(*) AGC=E Dynamic AGC value transmitted to the camera AGC value transmitted to the camera, , Change shutter setting for wing AGC=S mode Shutter Speed...
  • Page 52: Preset Mode Setting

    4.5 Preset Mode Setting Item Command Contents Preset ?pre Confirmation of preset status PREM=0 Preset Mode 0: Disable preset function(*) Preset Mode 1: Enable preset function, after power is switched ON, the PREM=1 first OK read data is registered within the reader as “preset” data. Preset Mode 2: Enable preset function, the preset data is registered within PREM=2 flash memory.
  • Page 53: Settings For Image Output

    4.7 Settings for image output Item Command Contents Trimming IMODE=0 Enable trimming Enable/Disable IMODE=1 Disable trimming Location of PX=aaa Coordinate of trimming (origin, x) a=0-1279 trimming PY=aaa Coordinate of trimming (origin, y) a=0-1023 WX=aaa Width for trimming from the origin a=1-1280 WY=aaa Height for trimming from the origin...
  • Page 54 4.8 General Operation / Help Item Command Contents Initialize Setting SET=DFT Set all default Save Setting WSETS Save setting Buzzer buz=a a=0; During Reading operation Buzzer off, a=1; Buzzer on (*) Digital CHATT=a Debouncing Time a=0 None、a=1; 10msec、a=2 20msec In/Output a=0;...
  • Page 55: Table Of Character Code

    4.9 Table of character code UPPER DATA ー タ ミ 。 ア チ ム 「 イ ツ メ " 」 ウ テ モ 、 エ ト ヤ ・ オ ナ ユ ヲ カ ニ ヨ & ァ キ ヌ ラ ィ...
  • Page 56: Specifications

    5.Specifications 5.1 General specifications Physical Dimensions External input and output - Length 56 mm - Serial Interface: RS-232C/USB 1.1 - Width 60 mm - Data form: ASCII - Depth 22 mm (without protrusions) - Transmission speed:1200bps - 115.2kbps - Weight approx.
  • Page 57 Reading Direction - -...
  • Page 58: Field Of View And How To Place The Unit

    5.2. Field of view and how to place the unit The field of view of TFIR-31DM is the same as TFIR-31H. However, for the direct parts marking application, the area with slash in the figures below is suitable. TFIR-31DM-F For matt surface For glossy surface マーキング面に光沢が無い場合...
  • Page 59: Dimensions

    5.3 Dimensions 5.3.1 F type (Front View) Reading window (the base point) 読み取り窓(基点) Y軸 Y-axis X軸 X-axis 視野方向 視野方向 Direction of view A B C D Teach Read 2-M3 hole for 2-M3取付穴 深さ19 - -...
  • Page 60: F Type (Front View)

    5.3.2 F type (Front View) 読み取り窓(基点) Y-axis Y軸 視野方向 2-M3 hole for 2-M3取付穴 深さ19 X軸 X-axis Depth: 19mm 視野方向 Direction of - -...
  • Page 61: Interface

    5.5 Interface 1) With Dsub9 connector Host connection:Dsub9 (female) Signal Pin # Inside Inside Outside Outside AC adaptor jack : EIAJ – TypeⅡ Signal Pin # 1950 1950 - -...
  • Page 62 2) USB Pin No Signal Function Directions Color of cable Half-duplex DAT- differential In & Out White signaling - Half-duplex DAT+ differential In & Out Green signaling + Ground Black 1950 Note: for TFIR-31DMU a USB connector plug A is used -...
  • Page 63 3) RS-232C (without connector) Signal Function Directions Color of cable White w/ Red dot Power Return / Signal Earth White w/ Black dot SD(TXD) Transmitted Data Output Pink w/ Red dot RD(RXD) Received Data Input Pink w/ Black dot RS(RTS) Request To Send Output Orange w/ Red dot...
  • Page 64 4) Circuit for inputting and outputting DIO (RS-232C) 4)-1 Synchronous Input 74HC14 (Toshiba) or similar 10kΩ Open Corrector 470Ω Pink (SYNC) Internal circuit 10kΩ 0.01μF Black (GND) 4)- 2 GO/NG output Max 50mA White (OUT) Electric Load Internal circuit Black (GND) DC5~30V -...
  • Page 65: Automatic Setup Mode

    6. Automatic setup mode 6.1 Overview The “setup mode” is the state in which the reading parameters are configured automatically. In the setup mode, the unit starts searching the best combination of the settings for camera sensitiveness described in the following list. --------------------------------The list of parameters-------------------------------- Shutter speed SHUTT=0 (1/30 second)
  • Page 66: The Procedure Of Automatic Configuration

    6.2 The procedure of automatic configuration Relation of function buttons and LEDs Function button Indicator LED # Mode Teach Read Normal Start Start Turn ON while Blink Turn ON Turn ON setup reading judgment is during serial during serial mode output communication communication...
  • Page 67 5) LED indicators start blinking after the unit finds the best combination of the reading parameters. If the reading rate is 0%, the unit is back to the state described in 3). The ways of blinking show the reading rate with the combination. Reading rate 100% (without image preprocessing) Reading rate 100% (with image preprocessing) Reading rate under 100%...
  • Page 68: Troubleshooting

    7.Troubleshooting 7.1 The unit does not work while pushing the read trigger switch. Is power supply voltage within specification? Power supply voltage should be DC 3V-6V. If the DC voltage is not within the specified range not only the unit will not operate, but there is a strong possibility of damaging the unit. Is power supply polarity correct? When it is connected with reverse polarity, the unit does not operate.
  • Page 69: Is The Reading Window Clean

    To avoid this, put the scanner in angle relative to the symbol. Is the reading window clean? If the window becomes dirty or stained, the image taken by the reader might not be good enough for reading. Clean with a lens cleaner or similar anti-scratching (non-abrasive) method.
  • Page 70: The Data Does Not Transmit Or The Data Itself Is Corrupted

    7.3 The data does not transmit or the data itself is corrupted. Is the setup with host computer correct? Please check whether the baud rate and frame format is the same as that of the host computer. If frame format differs, it may seem that data is transmitted incorrectly. Do you set fixed digit for ITF In some cases, cancellation of significant digits (reading it through with a few digits than a printed digits) in ITF(Interleaved 2 of 5) might be used.
  • Page 71 [Memorandum] - -...
  • Page 72 Warranty Obligations This warranty obligation is limited to terms set forth below: TOHKEN warrants this hardware product against defects one year form the date of purchase. <Warranty Coverage> 1. TOHKEN will repair the product at no charge, for hardware defects occurring when used in accordance with the manual and catalog, under normal operating conditions.
  • Page 73 TOHKEN CO., LTD Head quarters 2-7-1 Nishi-Shinjuku, Shinjuku-ku, Tokyo Japan 163-0710 Sales 03-5325-4311 to 4315 Sales Promotion 03-5325-4322 Nagoya office 4-2-12 Meieki, Nakamura-ku, Nagoya Japan 450-0002 Sales 052-565-9091 Osaka office 2-9-1 Higashi-Tenman, Kita-ku, Osaka Japan 530-0044 Sales 06-6353-5476 Fukuoka office...