Lafferty 920115 Installation & Operation Instructions

Lafferty 920115 Installation & Operation Instructions

Pump fed ss foamer

Advertisement

Quick Links

REQUIREMENTS
Ready-to-Use Chemical Solution
Temperature
Pressure
Flow
Supply Line
Compressed Air
Hose
Nozzle
OPTIONS
Stainless Steel Hose Racks
Large Stainless Steel Hose Rack
Foam Solution Check Valves & Strainer
Check Valve, PP, 1/2'' (EPDM)
Check Valve, PP, 1/2'' (Viton)
Check Valve, 316SS, 1/2", MF (Teflon)
Strainer, "Y", SS, 1/2" MF
Alternate Air Check Valve - EPDM Standard
Check Valve, Air, SS, 1/4" MM (Viton /
Hast)
Stainless Steel Foam Wand (Upgrade)
Convert PP Wand to SS (New Units)
WEIGHT & DIMENSIONS
Single Package
Shipping Weight
Shipping Dimensions
OVERVIEW
The Pump Fed SS Foamer is a medium volume foam applicator for projecting ready-to-use foaming chemicals on to any surface up close or at distances up to 12
feet. This stainless steel unit receives ready-to-use chemical solution from a central chemical feed system and creates rich, clinging foam by injecting compressed air
into the solution to greatly increase volume and coverage ability. The foam is then projected through the discharge hose, wand and fan nozzle.
Lafferty Equipment Manufacturing, LLC • 5614 Oak Grove Road • North Little Rock, Arkansas 72118
Lafferty Equipment Manufacturing, LLC
Installation & Operation Instructions
Model # 920115 · Pump Fed SS Foamer
up to 180°F
35 to 125 PSI
1.7 GPM @ 40 PSI
1/2"
up to 4 CFM
3/4" ID x 50'
50250
# 224150
# 491409
# 491411
# 491348SS-T
# 150350-1
# 491306
# 536603-X
24 lbs.
28" x 19" x 8"
www.laffertyequipment.com
501-851-2820
W A R N I N G ! R E A D A L L
I N S T R U C T I O N S B E F O R E
U S I N G E Q U I P M E N T !

Advertisement

loading

Summary of Contents for Lafferty 920115

  • Page 1 This stainless steel unit receives ready-to-use chemical solution from a central chemical feed system and creates rich, clinging foam by injecting compressed air into the solution to greatly increase volume and coverage ability. The foam is then projected through the discharge hose, wand and fan nozzle. Lafferty Equipment Manufacturing, LLC • 5614 Oak Grove Road • North Little Rock, Arkansas 72118...
  • Page 2 920115 • Pump Fed SS Foamer SAFETY & OPERATIONAL PRECAUTIONS UNIT FLOW RATES For proper performance do NOT modify, substitute nozzle, hose diameter or length. Manufacturer assumes no liability for the use or misuse of this unit. 1.59 Wear protective clothing, gloves and eye-wear when working with chemicals.
  • Page 3 920115 • Pump Fed SS Foamer - Page 3 -...
  • Page 4 920115 • Pump Fed SS Foamer Troubleshooting Guide Possible Cause / Solution Problem Startup Maintenance A) Foam surges and/or hose "bucks". 1, 2, 3, 4, 5, 6, 7, 8 10, 12, 13 B) Foam too wet. 2, 3, 4, 5, 6 10, 12, 13 C) Foam does not clean properly or too dry.