Download Print this page
Lafferty 920118 Installation & Operation Instructions

Lafferty 920118 Installation & Operation Instructions

Advertisement

Quick Links

REQUIREMENTS
Ready-to-Use Chemical Solution
Temperature
Pressure
Flow
Supply Line
Compressed Air
Hose
Foam
Rinse
Nozzle
Foam
Rinse
OPTIONS
Stainless Steel Hose Racks
Large Stainless Steel Hose Rack
Foam Solution Check Valves & Strainer
Check Valve, PP, 1/2'' (EPDM)
Check Valve, PP, 1/2'' (Viton)
Check Valve, 316SS, 1/2", MF (Teflon)
Strainer, "Y", SS, 1/2" MF
Alternate Air Check Valve - EPDM Standard
Check Valve, Air, SS, 1/4" MM (Viton /
Hast)
Stainless Steel Foam Wand (Upgrade)
Convert PP Wand to SS (New Units)
WEIGHT & DIMENSIONS
Single Package
Shipping Weight
Shipping Dimensions
OVERVIEW
The Rinse/Pump Fed Foam Hose Drop Station is a medium volume foam applicator for projecting ready-to-use foaming chemicals and for rinsing. This unit receives
ready-to-use chemical solution from a central chemical feed system and creates rich, clinging foam by injecting compressed air into the solution to greatly increase
volume and coverage ability. The foam is then projected through the discharge hose and fan nozzle on to any surface up close or at distances up to 12 feet. Rinse
through a separate hose with a unique and powerful 4-hole nozzle.
Lafferty Equipment Manufacturing, LLC • 5614 Oak Grove Road • North Little Rock, Arkansas 72118
Lafferty Equipment Manufacturing, LLC
Installation & Operation Instructions
Model # 920118 · Rinse / Pump Fed Foam Hose Drop Station
up to 160°F
35 to 125 PSI
1.7 GPM @ 40 PSI
3/4"
up to 3 CFM
3/4" ID x 50'
3/4" ID x 50'
50250
4 Hole Rinse Nozzle
# 224150
# 491409
# 491411
# 491348SS-T
# 150350-1
# 491306
# 536603-X
42 lbs.
28" x 28" x 8"
www.laffertyequipment.com
501-851-2820
W A R N I N G ! R E A D A L L
I N S T R U C T I O N S B E F O R E
U S I N G E Q U I P M E N T !

Advertisement

loading

Summary of Contents for Lafferty 920118

  • Page 1 The foam is then projected through the discharge hose and fan nozzle on to any surface up close or at distances up to 12 feet. Rinse through a separate hose with a unique and powerful 4-hole nozzle. Lafferty Equipment Manufacturing, LLC • 5614 Oak Grove Road • North Little Rock, Arkansas 72118...
  • Page 2 920118 • Rinse / Pump Fed Foam Hose Drop Station SAFETY & OPERATIONAL PRECAUTIONS UNIT FLOW RATES For proper performance do NOT modify, substitute nozzle, hose diameter or length. Manufacturer assumes no liability for the use or misuse of this unit.
  • Page 3 920118 • Rinse / Pump Fed Foam Hose Drop Station - Page 3 -...
  • Page 4 920118 • Rinse / Pump Fed Foam Hose Drop Station Troubleshooting Guide Possible Cause / Solution Problem Startup Maintenance A) Foam surges and/or hose "bucks". 1, 2, 3, 4, 5, 6, 7, 8 10, 12, 13 B) Foam too wet.