Setting Description - Cablematic BBM-B-TYPE 22 Manual

Outputs intelligent traffic signal controler
Table of Contents

Advertisement

1, the standard: the implementation of the latest national standard GA47-2002
2, the output drive capability: Each typical load capacity of 600W.
3, working voltage: AC80V ~ 270V 50 ± 2Hz
4, the ambient temperature: -40 ° C to +75 ° C
5, relative humidity: 5% ~ 95%
6, dielectric strength: more than 100M
7 Dielectric strength: voltage AC 1500V
8, impact, vibration: can withstand a variety of transport under normal operating conditions,
the impact and vibration.

Setting Description:

一、Current time settings:
Menu indicator panel "Menu" button to switch to the "current time" at the turn digital
display the current hour, minute, second; second single-digit flashes can set the time (24 hour
clock). Button of by Panel "left" and "right" buttons to select the need to modify the project; press
panel "addend" button and "subtrahend" button to modify the need to modify the project. Panel
"Save" button to save the current time to exit the time setting.
二、Boot time settings:
Menu indicator panel "Menu" button to switch to the "on time." At the digital tube 2,3 hours
boot time, the number of minutes of 5,6 digital tube display boot time; boot time is the number of
minutes of The digit flashes that can be set boot time (24 hour clock). Button of by Panel "left"
and "right" buttons to select the need to modify the project; press panel "addend" button and
"subtrahend" button to modify the need to modify the project. "Save" button to save the boot time
to exit the boot time set by the panel.
三、Off time settings:
Menu indicator panel "Menu" button to switch to the "off time" at 2,3 digital tube display the
number of hours of off time, 5,6-bit digital tube display the number of minutes of off time;
shutdown time the number of minutes digit flashes can set the shutdown time (24 hour clock).
Button of by Panel "left" and "right" buttons to select the need to modify the project; press panel
"addend" button and "subtrahend" button to modify the need to modify the project. Panel "Save"
button to save the off time to exit power off time setting.
四、The flashing time setting:
Menu indicator panel "Menu" button to switch to the "flashing" at, 4, 5, 6-bit digital tube
display flashes time; flashing single digits flashing can set the flash time (255 seconds). Button of
by Panel "left" and "right" buttons to select the need to modify the project; press panel "addend"
button and "subtrahend" button to modify the need to modify the project. Panel "Save" button to
save the flashing time to quit blinking time setting.
五、The East-west pedestrian to apply for a work time settings: