▪Finish tightening nut to make a water proof seal against the O-ring.
▪You may need to twist clear hose socket until completely tight and flush
with UVC.
▪Insert Green Matala section 2, Blue Matala Sec. 3, Gray Matala Sec. 4 &
Sec.5. Slide partition screen after Gray Matala.
▪Insert partitioning screen after the Gray Matala in section 5.
▪This prevents media from blocking the outlet pipe.
▪Place lid over the UVC and snap onto filter.
▪Attach UVC bulb into electric socket.
Caution: UVC bulb is delicate.
▪Cover cap has safety switch. Lamp will only light when fitted fully into
body.
▪Carefully insert UVC bulb into UVC body.
Caution: UVC bulb is delicate.
▪Tighten hand nut cap into UVC body.
▪Hand nut must be firm and snug to prevent water leakage into UV light.
▪Connect pump to BioSteps.
▪Do not turn UV on until you have leak tested all fittings.
▪If any leaks check O-rings and nuts.