Solid state microwave generator

Advertisement

Quick Links

SG 524
SOLID STATE MICROWAVE GENERATOR
450 W @ 2450 MHZ
TECHNICAL NOTE
(issue: April 2017)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SG 524 and is the answer not in the manual?

Questions and answers

Summary of Contents for MKS SG 524

  • Page 1 SG 524 SOLID STATE MICROWAVE GENERATOR 450 W @ 2450 MHZ TECHNICAL NOTE (issue: April 2017)
  • Page 2 (Cover Rear)
  • Page 3: Ce Declaration

    Electromagnetic comp. - Testing & measuring technique: immunity to conducted disturbance Compatibilità elettromagnetica - Tecnica di prova e misura: immunità disturbi condotti RF Reggio Emilia, April 2017 Marco Garuti - Gen Manager File: SG524_r3eng - April 2017 - Technical note: SG 524 page 1 of 16...
  • Page 4: Rohs Conformity

    Correction alarm code 1000 Corrections to the text, alarm table, software version May 2014 SG524_r2 Update norms. RoHS compliance declaration. Minor typing corrections. April 2017 SG524_r3 page 2 of 16 File: SG524_r3eng - April 2017 - Technical note: SG 524...
  • Page 5: Table Of Contents

    General description not be used in the residential, commercial and light-industrial General informations environment. The SG 524, when properly installed, complies with the limits Handling instructions of radio disturbance characteristic of a Group2, Class A equip- Handling warnings How to order ments as stated by EN55011.
  • Page 6: General Description

    ESC allows moving from one page to another, TAB (the button with the arrow) to scroll down the selection, As of today the SG 524 is offered in two versions: ENTER to confirm the selection. - the “Display” version with front panel manual commands Knob allows to modify a value when this is enabled.
  • Page 7: Cleaning

    3/4 of the Cleaning of air inlet: verify once a month. In case you need total depth. to remove dust then proceed as follow: File: SG524_r3eng - April 2017 - Technical note: SG 524 page 5 of 16...
  • Page 8: Environmental Conditions

    To lift always lean the rack over a proper supporting base. Equipment operation Wiring instructions Power-up procedure The SG 524 must be installed and serviced only by quali- Before powering-up the equipment, double check to have pro- fied personnel acquainted with the regulations covering the perly connected it, (look at the chapter “Wiring Instruction”...
  • Page 9: Meaning Of External Commands

    - via software through the USB serial port or the fieldbus alarm: when an alarm condition is present the unit will module (the latter option only for SG 524 vers. 1). It can not remain in this status. To exit from Alarm the Enabling com- be set in external mode using a signal.
  • Page 10: Firmware Upgrade

    It can be set through display command (and via fieldbus for vers. 1) The SG 524 version 2 (Display version) can also be opera- INTERLOCK FUNCTION: managed by CONN#2 pin 10-23 ted manually via the front panel commands. Some of the SG It is an external chain of contacts, that must be closed to have 524’s parameters can only be modified through the front panel...
  • Page 11: Manual Commands

    MANUAL or EXTERNAL or REMOTE. In Manual mode the running before entering into autotune mode. output power is adjusted using the rotating knob on the panel, File: SG524_r3eng - April 2017 - Technical note: SG 524 page 9 of 16...
  • Page 12: Bit Alarm Table

    Note*: the last alarm occured is permanently stored by the CPU , even in absence of main line, and can be verified using the Front Panel software (vers. 7.20 and over) page 10 of 16 File: SG524_r3eng - April 2017 - Technical note: SG 524...
  • Page 13: Conn.# 2 Wiring

    Conn # 3: RF Coax Accessories The 7/16 type female connector #3, installed on the rear panel, is the microwave output of the SG 524. To carry the microwave energy from the generator to the cavity/applicator we may offer several accessories, including a coax cable with length on request.
  • Page 14: Physical Dimensions

    Forward Power W Pin no. 2 (return on pin #15) : 1 V = 45 W Reverse Power W Pin no. 3 (return on pin #16) page 12 of 16 File: SG524_r3eng - April 2017 - Technical note: SG 524...
  • Page 15: Components Layout

    524...1MTCP) for the protocol implemented. CONN #4 Each SG 524 generator must be associated to an address: the two digital rotating switches must be used, the left switch sets the tens, the right sets the units. Depending from interface and protocol used, the address may be set by software too: refer to the specific documentation. In...
  • Page 16: Alarm Troubleshooting

    Front Panel, assembly with cover film Air Filter, honey comb mesh and frame 462702019 Line breaker with lever IGH22641300219M1 Fan 24Vdc, 132 mc/h VE8214JN Solid state power amplifier 450W 80SG05244 page 14 of 16 File: SG524_r3eng - April 2017 - Technical note: SG 524...
  • Page 17 Note*: the last alarm occured is permanently stored by the CPU, even in absence of main line, and can be verified using the Front Panel software (vers. 7.20 and over) File: SG524_r3eng - April 2017 - Technical note: SG 524 page 15 of 16...
  • Page 18: How To Order

    WR284 to 7/16, flange R32: p/n MWR32-COAX7/16L MKS Alter reserves the right to improve or modify this products, at any time, without obligation to notify any person or entity of such changes. No part of this publication may be reproduced without the express writ- ten consent of MKS.

Table of Contents