Safety Warnings - GRE LAGP8 Installation And Maintenance Manual

Led spotlight for pool
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
3. Hook mount
Fig. 1. Check that the bracket arm unit is firmly attached to the body of the above-ground pool projector.
Fig. 2. Feed the cable through the groove on the bracket arm unit until it is in the right position on the outside of the pool.
Fig. 8. Fasten the bracket arm unit to the edge of the above-ground pool by putting the hook support in place at the back
using the screws and corresponding nuts.
5. START-UP
The projector must only work submerged and fitted to the vertical walls of a pool. Never switch on a projector if it is not
submerged in water.
Connect the projector's cable to the driver and plug in the driver's plug to a 230 V power supply.

6. SAFETY WARNINGS

Ensure that the voltage the lamp receives is never greater than 12 V.
The floodlamp should only operate underwater while secured to the vertical walls of the pool. Never switch on the flood-
lamp if it is not underwater.
7. SAFETY WARNINGS
• Anyone who sets up this device must have the qualifications required to do so.
• Never open the light module.
• All contact with electric current must be avoided.
• The regulations in force on the prevention of accidents must be observed.
• The installation must comply with the standards of IEC 364-7-702: ELECTRICAL INSTALLATIONS OF BUILDINGS.
REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS. SWIMMING POOLS.
• The projector must be disconnected from the power supply whenever any maintenance jobs or the replacement of spare
parts must be carried out.
• Do not handle when feet are wet.
• There must be a distance of at least 4 m between the driver fed by a 230 V AC power supply and the pool.
• The light source of this luminaire is not replaceable. When the light source reaches the end of its service life, the whole
of the luminaire must be replaced.
• This projector has been designed to only run with the driver supplied. This driver is a SELV device that complies with
standards EN 61347-2-1 and EN 61347-2-13. The driver's transformer is a safety transformer that complies with IEC/
EN 60558-2-6.
• The power cable and wiring on these luminaires cannot be replaced if damaged. If damaged, the luminaire must be
destroyed.
• The luminaire should be fitted in such a way that it is not possible to stare at it from closer than 1 m.
• This above-ground pool projector is resistant to the pool treatments described below provided that the concentration
values do not exceed the following values:
Chlorine
Bromine
Salt chlorinator (NaCl)
Note: the pH of pool water must always be between 7.2 and 7.6.
TYPE OF TREATMENT
CONCENTRATION IN THE WATER
2 mg /l
5 mg/l
6 g/l
3