Signal Strength Test - Honeywell DT92 Manual

Wireless digital room thermostat
Hide thumbs Also See for DT92:
Table of Contents

Advertisement

Locating the DT92 Room Thermostat
For best performance, install in an open space where
DT92 can sense the room temperature, and where the
signal strength is high. The Room Thermostat can be
mounted on a wall or on the optional table stand. Leave
at least 30cm distance from any metal objects and at
least 1 metre from any other electrical equipment.
Do NOT position the thermostat near sources of heat
(radiators, hot air vents, TV or lights), near doors or
window, or in direct sunlight.
Select the preferred location and test the Signal
Strength before installation.

SIGNAL STRENGTH TEST

The Signal Strength Test is used to find a suitable
position for the DT92 thermostat, such that the signal
received by the BDR91 relay box is high strength. This
will optimize system performance.
The BDR91 relay box measures the strength of the
signal received from the room thermostat, and upon
request, sends this measurement back to the room
thermostat using the 2-way RF communication link.
This is expressed as a number between 0 and 5, where
5 is the highest strength. If this number is 2 or less, the
signal strength is too low, and room thermostat should
be repositioned. The DT92 room thermostat
continuously updates this measurement, every few
seconds.
DT92 WIRELESS DIGITAL ROOM THERMOSTAT
8
Poor signal, reposition
thermostat until signal
strength > 2
Strong signal,
thermostat can now be
mounted in this location