15.8 Instructions for the air extraction mode
For air extraction mode, a one-way flap should be in-
stalled.
Notes
¡ If a one-way flap is not included with the appliance,
one can be ordered from a specialist retailer.
¡ If the exhaust air is conveyed through the external
wall, a telescopic duct should be used.
15.9 Installation
Checking the wall
Check whether the wall is vertical and has sufficient
1.
load-bearing capacity.
Drill the hole depth in accordance with the length of
2.
the screws.
The wall plugs must have a secure grip.
The screws and wall plugs enclosed are only suit-
3.
able for use with solid brickwork.
Suitable fasteners must be used for other structures,
e.g. plasterboard, aerated concrete, Poroton blocks,
masonry bricks.
The maximum weight of the appliance is 40 kg.
4.
Preparing the wall
Mark a vertical centre line on the wall from the ceil-
1.
ing to the lower edge of the appliance.
Ensure that there are no electrical wires, gas pipes
2.
or water pipes in the area where holes are to be
drilled.
Use the enclosed template to mark where the
3.
screws are to be inserted and the outline of the at-
tachment area.
Drill five holes with a diameter of 8 mm to a depth
4.
of 80 mm for the attachments and push in the wall
plugs flush with the wall.
Installing the appliance bracket
Screw on the angle bracket for the flue duct.
1.
Screw on the brackets for the appliance until they
2.
are hand-tight.
Do not firmly tighten the screws.
Screw in the threaded pin, leaving it protruding out
3.
of the wall by 5–9 mm.
Installing the appliance
First remove the protective film from the back of the
1.
appliance and, following installation, remove the rest
of the film.
When mounting the appliance, ensure that it en-
2.
gages properly with the mounting supports.