Advertisement

Quick Links

Service manual – TR Comfortline / TR Ecoline
The recommended frequency of the maintenance procedures will depend on how often the equipment is
used and on the hardness of the water supplied at place of installation.
It is good practice to establish these routine procedures on a weekly basis and adjust the frequency based
on usage of the equipment.
Incl. spare parts list
1
Hygiene Equipment
Designed for People

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Comfortline and is the answer not in the manual?

Questions and answers

Summary of Contents for TR Comfortline

  • Page 1 Hygiene Equipment Designed for People Service manual – TR Comfortline / TR Ecoline Incl. spare parts list The recommended frequency of the maintenance procedures will depend on how often the equipment is used and on the hardness of the water supplied at place of installation.
  • Page 2: Table Of Contents

    Hygiene Equipment Designed for People Table of contents Introduction Manufacturer Spare parts list TR Comfortline Bathtub Overflow drainages Bathtub drainages Thermostatic mixers Cleaning system Air Spa Genesis Air Spa Esprit 500 Air Spa Esprit 500 – Wiring diagram Air Spa – Vento and Spatech blowers Autofill Engdata Autofill Engdata –...
  • Page 3: Introduction

    Hygiene Equipment Designed for People Introduction Dear customer, If you need spare parts and can’t find it in the spare parts list, contact TR Equipment.
  • Page 4: Manufacturer

    Hygiene Equipment Designed for People Manufacturer TR Equipment AB Rundelgatan 2 SE-573 35 Tranås Sweden Phone: +46 (0)140 38 50 60 www.trequipment.com info@trequipment.se...
  • Page 5: Spare Parts List Tr Comfortline

    Hygiene Equipment Designed for People Spare parts list TR Comfortline Spare parts 1a, b, c, d, e 2, 3 5a, 5b 8a, 8b 15a, 15b 20a, b, c...
  • Page 6 Hygiene Equipment Designed for People Spare parts list TR Comfortline Spare parts Position Part number Spare part 200033 Thermostatic mixer Grotherm 800 851884 Thermostatic mixer Grotherm 2000, Cool touch 851906 Thermostatic mixer Legionella, FMM900E 851905 Thermostatic mixer TMV2, FMM900E 851900...
  • Page 7: Overflow Drainages

    Hygiene Equipment Designed for People Spare parts list TR Comfortline Drainages 20b, c Tub drainages Overflow drainages Position Part number Spare part 829280 Overflow drainage, std, incl knob and drain plug 829279 Drain plug for overflow drainage 829280 851903 Overflow drainage, UK, optional 3426346 Drainage hose with Ø40mm plastic pipe...
  • Page 8: Thermostatic Mixers

    Hygiene Equipment Designed for People Spare parts list TR Comfortline Thermostatic mixers Position Part number Spare part 851883 Thermostatic mixer Grotherm 800 851884 Thermostatic mixer Grotherm 2000, Cool touch 851906 Thermostatic mixer Legionella, FMM9000E 851905-02 Filling spout FMM9000E 851905 Thermostatic mixer TMV2, FMM9000E...
  • Page 9: Cleaning System

    Hygiene Equipment Designed for People Spare parts list TR Comfortline Cleaning 26, 27...
  • Page 10 Hygiene Equipment Designed for People Spare parts list TR Comfortline Cleaning Position Part number Spare part 851868 Cleaning handle, chromed, chromed 851877 Bracket for cleaning handle 829096 Yellow cleaning hose 851875 Pipe interrupter 829289-02 Valve key 829289 Cleaning valve R15 / ½” incl, key, disc and valve stem 829307 Valve stem R15 / ½”...
  • Page 11: Air Spa Genesis

    Hygiene Equipment Designed for People Spare parts list TR Comfortline Air spa – Balboa Genesis (from 2018 and serial number 204610 onwards) 45, 46 48a, b, c 41, 42...
  • Page 12 Hygiene Equipment Designed for People Spare parts list TR Comfortline Air spa – Balboa Genesis Position Artikelnummer Reservdel 860000 Blower Genesis 860002 Hose cuff 860001 Hose clamp 860003 Blower hose 860007 Check valve 860008 Control panel 860009 Control panel ring, chromed...
  • Page 13: Air Spa Esprit 500

    Hygiene Equipment Designed for People Spare parts list TR Comfortline Air spa – Spare parts Air spa Esprit 500 used on serial numbers 28117 (2010) to and including 204377 (2017) + serial numbers 204676 (2018) and 204840 (2018). 57, 58...
  • Page 14 Hygiene Equipment Designed for People Spare parts list TR Comfortline Air spa – Spare parts Airs spa Esprit 500 Position Artikelnummer Reservdel 851810 Blower Esprit 500 Contact TR Pneumatic starter, micro switch Equipment 851808 Black blower hose 3430654 Bracket 851281...
  • Page 15: Air Spa Esprit 500 - Wiring Diagram

    Hygiene Equipment Designed for People Spare parts list TR Comfortline Air spa – Wiring diagram Air spa Esprit 500 (before serial number 204610)
  • Page 16: Air Spa - Vento And Spatech Blowers

    Hygiene Equipment Designed for People Spare parts list TR Comfortline Air spa – Vento blower If your tub is equipped with a Vento blower, replace the blower with following parts: Position Artikelnummer Reservdel 851810 Blower Esprit 500 3430654 Blower bracket 851281 Dampers (4pcs/bracket).
  • Page 17: Autofill Engdata

    Hygiene Equipment Designed for People Spare parts list TR Comfortline Autofill – Spare parts Engdata 2018 used on serial numbers 204609 (2018) onwards. When mounting the sensors the symbol shall be mounted towards the fiberglass. White side outwards.
  • Page 18 Hygiene Equipment Designed for People Spare parts list TR Comfortline Autofill – Spare parts Engdata 2018 Position Artikelnummer Reservdel 851907 Controlpanel Seritronic 818357 Circuit board incl. enclosure 829185 Solenoid valve 24VAC incl. coil 829187 Power cord with coil connector 829188...
  • Page 19: Autofill Engdata - Wiring Diagram

    Hygiene Equipment Designed for People Spare parts list TR Comfortline Autofill – Wiring diagram Engdata 2018 Wiring diagram for sensors used 2018 Wiring diagram for sensors from 2019 week 36. and part of 2019. When replacing old sensors with the new version follow the new wiring diagram.
  • Page 20: Autofill Esprit

    Hygiene Equipment Designed for People Spare parts list TR Comfortline Autofill – Spare parts Esprit used on serial numbers 29826 (2011) to and including 204476 (2017) + serial number 204969 (2018).
  • Page 21: Autofill Esprit - Replace Circuit Board And Control Panel With Engdata

    Hygiene Equipment Designed for People Spare parts list TR Comfortline Autofill – Spare parts Esprit Position Artikelnummer Reservdel 851838-02 Control panel Esprit 851839 Circuit board 851838-03 Level sensor 851838-04 Solenoid valve 24VAC incl. coil 851838-05 Power cord with coil connector...
  • Page 22: Autofill Esprit - Wiring Diagram

    Hygiene Equipment Designed for People Spare parts list TR Comfortline Autofill – Wiring diagram Esprit...
  • Page 23: Led - Slimlight

    Hygiene Equipment Designed for People Spare parts list TR Comfortline LED light – Slimlite used on serial number 204610 (2018) onwards. Position Artikelnummer Reservdel 851828-05 Complete unit LED spotlight incl. control button, transformer, cable gland, plastic cylinder & cables.
  • Page 24: Led - Aerospa

    Hygiene Equipment Designed for People Spare parts list TR Comfortline LED light – Aerospa used on serial numbers 203700 (2017) to and including 204580 (2018) + serial number 204840 (2018). Wiring diagram LED light Aerospa Position Artikelnummer Reservdel 851828-03 Complete set of LED spot, circuit board, transformer, enclosure and control panel.
  • Page 25: Led - Matrex Systems

    Hygiene Equipment Designed for People Spare parts list TR Comfortline LED light – Matrex used on serial numbers 28117 (2010) to and including 203531 (2017) + serial numbers 203992 (2017) and 204969 (2018). NEW LED Ø79mm with 4-lead connector OLD LED Ø64mm or Ø79mm with 6 lead connectors...
  • Page 26: Music - Polyplanar

    Hygiene Equipment Designed for People Spare parts list TR Comfortline Bluetooth/AUX Music system – Polyplanar from serial number 1709-203870 onwards. Position Artikelnummer Reservdel 851844 Complete set of Control display, amplifier and AUX connector. 851844-02 Control display 851845 AUX connector 819385...
  • Page 27: Music - Aersospa

    Hygiene Equipment Designed for People Spare parts list TR Comfortline Bluetooth/AUX Music system – Aerospa used on serial number 203735, 20739, 203863, 203915, 203931, 204148 & 204840. All serial numbers from year 2017. Position Artikelnummer Reservdel 851843 Complete set circuit board, amplifier, speakers and AUX...
  • Page 28: Music - Matrex

    Hygiene Equipment Designed for People Spare parts list TR Comfortline Music system -Matrex from serial number 28117 (2010) to and including 203992 (2017) + serial number 204969 (2018) Position Part number Spare part 851834-02 Circuit board for old MP3-system 851834-03...
  • Page 29: Sheperds Crook

    Hygiene Equipment Designed for People Spare parts list TR Comfortline Sheperds Crook 101, 102, 103, 104 When ordering a hose for Sheperds Crook order 829094, -02, -03 & -04 for a complete hose Position Part number Spare part 3331102 Sheperds crook...
  • Page 30: Height Adjustment

    Hygiene Equipment Designed for People Spare parts list TR Comfortline Height adjustment Position Part number Spare part 850999 - Hand control Vibradorm system. ES00920-1000015. ES00920- 1000015 851894 Hand control Dewert (Replaced by 851894-03) 851894-03 Hand control Dewert 851815 UP/DOWN control panel...
  • Page 31: Backflow Preventer Between Shower Hose And Thermostatic Mixer

    Hygiene Equipment Designed for People Spare parts list TR Comfortline Backflow preventor between shower hose and mixer When using a backflow preventer between shower hose and mixer, long version of mixer feet is required. Position Part number Spare part 851879...
  • Page 32: Spare Parts List Tr Ecoline

    Hygiene Equipment Designed for People Spare parts list TR Ecoline 1, 2 3, 4, 5 7, 8 9a, b, c, d Position Part number Spare part 851883 Thermostatic mixer Grotherm 800 851872 Mixer feet 851872-02 Mixer feet, extra high 851868...
  • Page 33: Service Instructions Tr Comfortline

    Service instructions TR Comfortline How to replace a lifting column – New version from serial number 29285 (2011). Lifting columns on the new version of the Comfortline bathtub are fastened with Black mounting plates and stabilizing bars. New version of Comfortline bathtub...
  • Page 34 How to replace a lifting column – New version Two people are required to replace lifting columns. To get a better view how lifting columns are mounted on the Comfortline bathtub the picture below show the Comfortline bathtub upside down and without skirt.
  • Page 35: How To Replace A Lifting Column - Old Version, Stabilizing Bars

    How to replace a lifting column – Old version before serial number 29285 (2011). Lifting columns on the old version of the Comfortline bathtub have no mounting brackets around the lifting columns. The lifting columns are fastended with stabilizing bars mounted onto the lifting columns.
  • Page 36 Hygiene Equipment Designed for People Service instructions TR Comfortline How to replace a lifting column – Old version...
  • Page 37 Hygiene Equipment Designed for People Service instructions TR Comfortline How to replace a lifting column – Old version Two people are required to replace lifting columns. Electric cable from the control box to the lifting column. Four screws on each Side of the lifting column.
  • Page 38: How To Replace The Control Box

    Hygiene Equipment Designed for People Service instructions TR Comfortline How to replace the control box The control box is placed behind the service hatch at the tap end. The control box is fastened with two screw and nuts. 1. Unplug the power cord from the control box.
  • Page 39: How To Calibrate/Initialize The Lifting Columns (Old And New Version)

    Hygiene Equipment Designed for People Service instructions TR Comfortline How to calibrate/initialize the lifting columns From July 2013: Following calibration instruction is for bathtubs supplied from July 1 , 2013: - Press the UP and DOWN button simultaneously on the hand control to calibrate the lifting columns.
  • Page 40: Air Spa - How To Replace The Esprit 500 Blower

    Hygiene Equipment Designed for People Service instructions TR Comfortline Air Spa - How to replace the Esprit 500 blower The Esprit 500 blower is located behind the service hatch at the tap end. Before replacing the blower, disconnect the blower from the circuit board. The circuit board is in an enclosure underneath the tub.
  • Page 41: Air Spa - How To Replace The Vento Blower

    Hygiene Equipment Designed for People Service instructions TR Comfortline Air Spa - How to replace the Vento Blower The Vento blower is located behind the service hatch at the tap end. The Vento blower is no longer available, but it is possible to install the Esprit 500 blower instead. See page 14 for parts needed.
  • Page 42: Air Spa - How To Replace The Genesis Blower

    Hygiene Equipment Designed for People Service instructions TR Comfortline Air Spa - How to replace the Genesis blower The Genesis blower is located underneath the tub at the head end. Disconnect the blower power cord from the mains supply on the tub.
  • Page 43: Autofill - How To Replace The Solenoid Valves

    Hygiene Equipment Designed for People Service instructions TR Comfortline Autofill - How to replace a solenoid valve The solenoid valves are located behind the service hatch and lifting column at the tap end of the tub. To replace a solenoid valve, we recommend that the lifting column is removed. Two people are required when replacing a solenoid valve.
  • Page 44: Autofill - How To Retrofit The Esprit System To A Engdata System

    Hygiene Equipment Designed for People Service instructions TR Comfortline Autofill - How to retrofit the Esprit system with the Engdata system The enclosure for the Esprit Autofill system is located underneath the tub. Disconnect the power to the tub and unscrew the enclosure lid.
  • Page 45: Routine Maintenance

    Clean the strainers on the shower handle by rubbing it with your thumb. If your Comfortline II is equipped with a cleaning system: Make sure there is cleaning liquid in the cleaning container. Clean the strainers on the cleaning shower handle by rubbing it with your thumb.
  • Page 46: Monthly Maintenance

    Warning Scalding risk when flushing with hot water! Warning Shower hoses on the TR Comfortline bathtub manage 60°C /140°F for 10 minutes. Warning Maintenance and/or repairs may only be carried out by the manufacturer or qualified staff authorized by the manufacturer. Otherwise warranty expires immediately.
  • Page 47: Annual Maintenance

    Initialize/calibrate the lifting columns according to the instructions described in the Operating manual. See Initializing in the table of content. If your Comfortline II is equipped with cleaning system check the OPEN/CLOSE valve to see if it open and close the valve properly. Replace valve stem if necessary.
  • Page 48: Maintenance Every 3, 5 And 12 Years

    If the thermostatic mixer is supplied by TR Equipment, it´s covered by warranty but problems related to the quality of the water is not covered by the warranty from TR Equipment.
  • Page 49: Annual Maintenance & Inspection

    Cleaning function: If your Comfortline II is equipped with the cleaning function perform a function test. Start the cleaning function by turning the key on the tub side counterclockwise and make sure that cleaning detergent and water is mixed properly.
  • Page 50 Comfortline II are equipped with, how it works and how to clean it. If your Comfortline is equipped with the Esprit Air Spa make sure that the Air jet valves are in correct position. See Operating manual for correct position.
  • Page 51: Maintenance Check List

    Hygiene Equipment Designed for People Routine maintenance TR Comfortline Check list Annual maintenance Comfortline II Visual control Does the bathtub stand securely Comment: Action: on the floor? Is the bathtub in the lowest Comment: Action: position before use? Are there any visible damages on...
  • Page 52 Hygiene Equipment Designed for People Routine maintenance TR Comfortline Electrical connections Inspect the electrical installation Comment: Action: and the equipment according to local requirements. Is the power cord in good Comment: Action: condition and without damages? Is the power cord properly...
  • Page 53 Hygiene Equipment Designed for People Routine maintenance TR Comfortline Function control of Lifting columns, Thermostatic mixer and drainage Initialize/calibrate the lifting Comment: Action: columns according to instructions in the Operating manual. Is it possible to raise and lower Comment: Action:...
  • Page 54 Hygiene Equipment Designed for People Routine maintenance TR Comfortline Function control of Lifting columns, Thermostatic mixer and drainage Does the switch for the shower Comment: Action: function work OK? Also read the manual from the supplier of the Thermostatic mixer if additional controls need to be performed.
  • Page 55 Hygiene Equipment Designed for People Routine maintenance TR Comfortline Function control, Cleaning system Is the bathtub equipped with this option? Yes Is the liquid container filled with Comment: Action: cleaning detergent? Is it possible to Open and Close Comment: Action:...
  • Page 56 Hygiene Equipment Designed for People Routine maintenance TR Comfortline Function control Air Spa Is the bathtub equipped with this option? Yes Possible to turn the Air Spa ON Comment: Action: and OFF? Does the Dry blowing Comment: Action: function/purge work?
  • Page 57 Hygiene Equipment Designed for People Routine maintenance TR Comfortline Function control Autofill Bathtub equipped with this option? Yes Possible to start the Autofill Comment: Action: function? (Mixer must be fully open) Does the Autofill function shut off Comment: Action: when it reaches the first and...
  • Page 58 Hygiene Equipment Designed for People Routine maintenance TR Comfortline Function control Music system Bathtub equipped with this option? Yes Possible to start the Music system Comment: Action: and to turn it OFF? Does the Bluetooth connection Comment: Action: work? (Can only be connected to...

This manual is also suitable for:

Ecoline

Table of Contents