3. Operating modes

The Mod. A 1735 – A 1835 and A 1735B – A 1835B boards can be controlled, either
locally or remotely, through the SYX527 software interface. For details on SYX527
system operation, please refer to the User's Manual of this product. The following
sections contain a description of commands available for the board control and status
monitoring.
3.1

Output control and monitoring

For each output channel, it is possible, through the SYX527 system, to perform the
following operations:
Assign to channel a symbolic name
Set output voltage (VSET)
Set max. output current (ISET)
Set output voltage software limit (SVMAX)
Set voltage ramp-up speed (RAMP-UP)
Set voltage ramp-down speed (RAMP-DOWN)
Set TRIP parameter
Enable/disable POWER ON option
Switch channel ON/OFF
Monitor output voltage (VMON)
Monitor output current (IMON)
Monitor channel status
If the POWER ON option is enabled, the channel, at POWER ON, is restored in the same
condition it was before the POWER OFF or RESET; if this option is disabled, at POWER
ON or after a RESET, the channel is kept OFF independently from its previous condition.
The following messages may be returned by the SYX527 when monitoring the channel
status:
OFF
RUP
RDWN
OVC
NPO :
00101/00:17XXx.MUTx/08
THE MOD. A 1735 and A 1835 BOARDS REQUIRE
SYX527 FIRMWARE VERSION 1.09.04 OR LATER
(channel turned OFF)
(channel ramping up)
(channel ramping down)
(channel in OVERCURRENT condition)