[999] Reset Tofactorydefaults; Placement Testingwirelessdevices; Programming Worksheets; Module Lables - DSC neo HSM2HOST Manual

Table of Contents

Advertisement

1.
Enter Installer Programming section [804][990] then select one of the following sub-sections:
[001] –Allzones
l
[002] –Repeaters
l
[003] –Sirens
l
[004] –Wirelesskeys
l
[005] –keypads
l
2.
Press [*] to select a wireless device type. The first available device is displayed.
3.
Use the scroll keys to view the enrolled devices.
Note:
This option is not fully supported by LED and ICON keypads.
[804][999] Reset to Factory Defaults
Selecting this option resets HSM2HOST programming to factory default settings.
[904] Placement Testing Wireless Devices
The following test modes are available:
[904][001]-[128] – Test wireless zones
l
[904][521]-[528] – Test all repeaters
l
[904][551]-[566] – Test all sirens
l
[904][601]-[632] – Test all wireless keys
l
[904][701]-[716] – Test all keypads
l
Two test results are provided:
24-hour: Average results of signal strength testing over a 24-hour period.
l
Now: Signal status results of the current test.
l
A flashing Trouble LED indicates RF interference. The following status indicators may be displayed:
LCD
Icon* LED+ Status
Strong
1
9
Good
2
10
Poor
3
11
NotTest 5
13
NotTest 5
13
*For Icon keypads, digit 1 indicates 24-hour test results; digit 2 indicates Now test results.
+For LED keypads, the first digit indicates 24-hour results; the second digit indicates Now test results.
Note:
For EN/UL/ULC installations, only STRONG signal levels are acceptable.

PROGRAMMING WORKSHEETS

[000] Module Lables

firealarmresources.com
Strongsignalstrength
Goodsignalstrength
Poor signalstrength
Displayedasthe Nowresultif notestwasperformed
Alwaysdisplayedasthe 24-hour resultwhentestingwirelesskeys
- 11 -

Advertisement

Table of Contents
loading

Table of Contents