SMC Networks AL430-1 Series Operation Manual

Micro mist lubricators float switch

Advertisement

Quick Links

Micro Mist Lubricators (Float Switch)
Model AL430-02~04-1S-1/-2
Operation Manual

Specifications

Modell
Port size
Fluid
Ambient and fluid temperature
Proof pressure
Operating pressure range
Oil capacity
Recommended lubricant
Bowl material
Bowl guard
Weight
Switch
Proof pressure
Max. working pressure
Ambient and fluid temperature
Max. Contact Point Capacity
Max. Operanting Current
Max. Operating Voltage
Contact Constitution
Standards
AL430
1/4, 3/8, 1/2
0.05 - 0.2 MPa
3
170 cm
Class 1 turbine oil (ISO VG32)
Polycarbonat
Aluminium Die Cast
1.2 kg
AL430-#-1
air
5° - 60°C
1.0 MPa
1000 cm
Metal
IS400-#-X209
1.5 MPa
1.0 MPa
5° - 60°C
AC: 50 VA, DC: 50 W
AC: 0.5 A, DC: 0.5 A
AC: 50 V, DC: 75 V
1a, 1b
Product do not need CE-marking as they're out of
scope
3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AL430-1 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SMC Networks AL430-1 Series

  • Page 1 Micro Mist Lubricators (Float Switch) Model AL430-02~04-1S-1/-2 Operation Manual Specifications Modell AL430 AL430-#-1 Port size 1/4, 3/8, 1/2 Fluid Ambient and fluid temperature 5° - 60°C Proof pressure 1.0 MPa Operating pressure range 0.05 - 0.2 MPa Oil capacity 170 cm 1000 cm Recommended lubricant Class 1 turbine oil (ISO VG32)
  • Page 2 Intended Use The Mirco Mist Lubricator has been designed for lubricating and cooling ball bearings, plain bearings, gears, chains to prevent them from wearing an to reduce friction. Unlike conventional oilers (oil fog oilers), it will produce very fine oil mist, thus making it possible to transfer lubricant to pneumatic equipment at the further distance with no waste of lubricant.
  • Page 3 Construction and Operation The float made of foam material which houses permanent magnets moves up and down as liquid level fluctuates. It slides up- and downward in reference to the switch holder, turning the reed switch on and off. Caution Required in Installation Install the unit so that the float may by vertical.
  • Page 5 Item Part name Material Body Zinc Die Casting Bowl Assembly Nozzle Holder Assembly Brass BAR Plate Brass Plate Adjust Screw Air Stainless Steel Wire Name Plate Polystel Name Plate Polystel Adjust Screw Oil Brass BAR Dripe Tube Copper Tube Name Plate O-Ring Siphon Tube Assembly Plug Assembly...