    WARNING IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS DANGER To avoid possible equipment electric shock, special care should be taken when the pump is used as aeration equipment. For each of the following situations, do not attempt to repair yourself, return the air pump to an authorized service facility for servicing, or discard the pump.
  • Page 3 D) Do no block the air being discharged. Pump must have sufficient room to allow for heat dissipation. Under the extreme operating temperature conditions which may be caused by failure to Observe cautions C) or D), pump will automatically switch off until cool. DO NOT REMOVE PUMP CASING UNTIL UNIT IS DISCONNECT FROM MAIN SUPPLY.
  • Page 4: Operation And Maintenance

    volt circuit as indicated on the sticker! For Canada, USA: the nominal volt circuit is 110-120 volt. Australia is 240 volt. 220 volt for other countries. 3. OPERATION AND MAINTENANCE When the pump is connected to a proper receptacle, the pump will operate. The filter must be periodically cleaned or replaced.
  • Page 11 MAINTENANCE Cleaning the filter: FILTER MUST BE CLEANED EVERY 6 MONTHS I) Undo the cover bolt securing the filter cover to the pump housing, and remove the filter pad. (Figure 3) II) Gently dust the filter pad then wash in mild, soapy water and dry.
  • Page 12 List of repair parts for 25L-120LH 25L/25LP HK-M25 Magnet 40L/40LP HK-M40 60L/80L HK-M60/80 80LH HK-M80H 100L HK-M100/150 1 pcs per set 120L/120LH HK-M120/120H/200 25L/25LP HK-D25 Chamber Block 2 pcs per set 40L/40LP HK-D40 Includes: 60L/80L/80LH HK-D60/80 Casing Block Diaphragm Mounting Block 100L/120L/120LH HK-D100/120 25LP/40LP...
  • Page 13 List of repair parts 150L-250L Magnet 150L HK-M100/150 x2set 200L HK-M120/120H/200 x2set 1 pcs per set 250L HK-M250 x2set Chamber 150L HK-D100/120 x2set Block 200L 250L 2 pcs per set Includes: Casing Block Diaphragm Mounting Block Filter Pad 150L HK-F150/200/250 200L 250L 1 pcs per set...
  • Page 14: Guarantee Provisions

    MATALA WATER TECHNOLOGY CO., LTD. GUARANTEE PROVISIONS 1) This Air pump/compressor has a limited guarantee for 3 year from the date of purchase provided that: [a] It is operated in accordance with the instruction manual. [b] Any repairs to the Air pump, which must be accompanied by this certificate are undertaken or authorized by the dealer or distributor from whom it was purchased.
  • Page 15 100L, 120L, 120LH TROUBLE SHOOTING A. If you plug power cable but Air Pump do not turn-on: 1. Please open the Pump housing (Please see operation manual page 5 Process 1~5) and check the parts 8 (Security Stopper). If the Security Stopper the Triangle symbol like (picture 1) is wrong. That is because the shipment or people who movement the air pump in wrong way.
  • Page 16 MATALA LINEAR AIR PUMP DIAPHRAGM REBUILD INSTRUCTIONS MATALA 40L, 60L, 80L, 80LH shown Your new diaphragm kit includes two diaphragms. Each diaphragm consists of two halves. Also included is a bag with new nuts and washers. Tools you will need: Flat head screw driver, Phillips head screw driver, Adjustable wrench.
  • Page 17 7) Use a Phillips screw driver and remove the 4 screws which connect the diaphragm to the motor plate. You might have to use a flat head screw driver to separate the two halves of the diaphragm. 8) Use an adjustable wrench to remove the nut on the diaphragm. This will separate the magnet.
  • Page 18 11) Align the new half diaphragm properly with the magnet screw and the motor plate. Push the diaphragm completely until it touches the magnet screw. You might need to push the soft rubber from behind with your finger. Use the wrench to screw on the new washer and nut.
  • Page 19 15) After both diaphragms have been replaced. 16) Replace the outer metal housing onto the base and tighten the 4 screw. Wash the square air filter with tap water and shake dry. Reinstall into the top of metal housing and replace the filter cover. Congratulations, you’ve done it!