  • Page 1 Deseo Cresnet Manual Deseo Cresnet Manual Basalte bvba hundelgemsesteenweg 1a 9820 merelbeke belgium 1 / 17 v0.6 © 2020 basalte...
  • Page 2 ® device, which can be programmed in SIMPL Windows using the Basalte Deseo Configuration Module. With the OLED user interface, you can adjust the set point, fan speed and temperature modes. Deseo also has an integrated temperature and humidity sensor.
  • Page 3: Installation

    60mm. The screws must be installed vertically. Using screws that are too big might hinder the mounting of the front cover onto the Basalte Deseo keypad. When mounted, the front cover should hide the keypad completely. If not, the connection...
  • Page 4: Identifying The Parts

    Deseo Cresnet Manual Identifying the parts 2.2.1 Front view 1.7” OLED-display Touch sensor up Touch sensor down Touch sensor left Touch sensor right Opening to screw the device into the wall box Guide for the deseo front cover Temperature/Humidity sensor...
  • Page 5: General Functions

    Manual General functions The Basalte Deseo keypad has 4 touch sensitive areas: the upper, lower, left and right sensor. The upper and lower sensor can be used to adjust the setpoint. The left sensor is used to browse through the available fan levels.
  • Page 6: Thermostat Modes

    A multitouch event occurs when the user simultaneously touches the upper and lower surfaces of the device. The short and long multitouch can be enabled or disabled in the ‘Basalte Deseo Configuration’ module. The delay for the multitouch long press is adjustable from 0.5 s to 5.0 s.
  • Page 7: Single Mode

    Deseo Cresnet Manual 3.5.1 Setpoints After starting the Deseo the default setpoint will be 70°F or 21 °C. The Deseo can support 2 different setpoint approaches. 3.5.1.1 Single mode In single mode, only one setpoint is available. For this reason, there will be one setpoint for all thermostat modes.
  • Page 8: Fan Modes

    A temperature compensation is available to anticipate on any environmental factors that might disturb the temperature measurement. Humidity Each Basalte Deseo keypad has a humidity sensor to report the relative humidity on the Cresnet bus. The humidity is reported on the analog output . The serial output will <Internal_Humidity>...
  • Page 9 Identify This Device ... button when right-clicking a Basalte Deseo again. A new pop-up- window gives an overview off all Cresnet devices in identification mode. A request is sent on the Cresnet bus to the selected Basalte Deseo. The Polling Mode Status says, ‘Start requested, Start in progress’.
  • Page 10 Deseo Cresnet Manual Programming in SIMPL Windows Adding a Basalte Deseo keypad A Basalte Deseo keypad is added to the Cresnet Bus like C2N-CHIP. Please refer to the demo project. An overview of all available signals on the Basalte Deseo symbol:...
  • Page 11 Depending of the report type, the temperature will be updated every 60 seconds, or on every temperature change of 0.5° Celsius. (equal to 0.9° Fahrenheit) The temperature format and report type can be set using the ‘Basalte Deseo Configuration’ module. 11 / 17 v0.6...
  • Page 12 Analog output: Reports the relative humidity of the built-in humidity sensor in whole <Internal_Humidity> numbers. The humidity report type can be set using the ‘Basalte Deseo Configuration’ module. Analog inputs: The current heat and cool setpoint temperature to display on the display.
  • Page 13 Depending of the report type, the temperature will be updated every 60 seconds, or on every temperature change of 0.5° Celsius. (equal to 0.9° Fahrenheit) The temperature report type can be set using the ‘Basalte Deseo Configuration’ module. Serial output: Reports the relative humidity in following format “xx.x”.
  • Page 14 Each Basalte Deseo on the Cresnet bus requires a ‘Basalte Deseo Configuration’ module. This module allows to change the parameters for each Deseo, and to send this custom configuration to the Basalte Deseo. Make sure to include the ‘Basalte Deseo Configuration.umc’...
  • Page 15 Deseo Cresnet Manual An overview al all available signals and parameters on the Basalte Deseo Configuration symbol: Signal Name and Type Description Digital input: When a High pulse is sent on this input, all configured parameters are sent in 1 configuration string to the corresponding Basalte Deseo <Initialize>...
  • Page 16 Deseo Cresnet Manual Parameter: Defines the mode of the Multitouch. <Multitouch Mode> Available settings: Disabled Short Press Short/Long Press Parameters: Defines the available Fan modes that can be selected on the Deseo. <Fan Mode Low> Available settings: <Fan Mode Mid>...
  • Page 17 Due to environmental factors, a humidity offset may be required. <Humidity Compensation> Available settings range from -30% to +30%. Questions or remarks? Contact your Basalte representative or get in touch with us at support@basalte.be or call our head office at +32 9 385 78 38.