Advertisement

Quick Links

READ AND SAVE THESE INSTRUCTIONS
FUSION
USER
MANUAL
PN 20-00367
G-SERIES GMS4H, GMS6H
& GMS8H HEATED
SERVICE CASES
Model GMS6H
Shown at Right
Model GMS8H
Shown at Left
Model GMS4H.............51"L* x 43 3/8"D^ x 51 51 5/8~
Model GMS6H.............75 3/8"L* x 43 3/8"D^ x 51 51 5/8~
Model GMS8H............99 3/4"L* x 43 3/8"D^ x 51 51 5/8~
*Includes End Panels (Deduct 2 1/4" If No End Panels)
~From Floor to Top of Unit ^50 3/8" With Rear Ledge Raised
Structural Concepts Corp. ∙ 888 E. Porter Rd ∙ Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 ∙ www.structuralconcepts.com
USER MANUALS\20-00367_FUSION_HTD SVC CASE_USER MANUAL_GMS(L)H
Rev H Date: 07/07/2022

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GMS4H and is the answer not in the manual?

Questions and answers

Florida universal cooling inc
March 25, 2025

Hi , I have a refrigerator Avanco AP49R and the evapotor fans no running in defrost, I need the setting for this control please

Lazaro Pena
March 26, 2025

Hello. I’m wondering how I can change the desired frost temperature and interval between defrost cycles.

Subscribe to Our Youtube Channel

Summary of Contents for Fusion GMS4H

  • Page 1 Shown at Right Model GMS8H Shown at Left Model GMS4H……...….51”L* x 43 3/8”D^ x 51 51 5/8~ Model GMS6H………..75 3/8”L* x 43 3/8”D^ x 51 51 5/8~ Model GMS8H……...…99 3/4”L* x 43 3/8”D^ x 51 51 5/8~ *Includes End Panels (Deduct 2 1/4” If No End Panels) ~From Floor to Top of Unit ^50 3/8”...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS OVERVIEW / CONDITION TYPE / TEMP / COMPLIANCE / WARNINGS / PRECAUTIONS / WIRING ..…………………………………………………………..…………………………………. INSTALLATION INSTRUCTIONS: SKID REMOVAL / CASE ALIGNMENT, ADJUSTING & SEALING …………………..………………..………………………………………………………. INSTALLATION INSTRUCTIONS, CONT’D: SEALING AND BOLTING HEATED CASES TOGETHER …………………………………………………………………………………….……... START-UP / LIGHTING / CASE TEMP. / CAREL® iJF PROGRAMMABLE CONTROLLERS / OPERATION …………………………………………………………………………………………..
  • Page 3 OVERVIEW / TYPE / TEMP / COMPLIANCE / WARNINGS / PRECAUTIONS / WIRING - PAGE 1 of 2 INTEGRATED AVERAGE PRODUCT TEMPERATURE OVERVIEW This Fusion merchandiser is designed for dry heating  The Structural Concepts® Fusion Service Deli operations throughout product area. Heat is generated...
  • Page 4: Wiring

    OVERVIEW / TYPE / TEMP / COMPLIANCE / WARNINGS / PRECAUTIONS / WIRING - PAGE 2 of 2 PRECAUTIONS REFRIGERANT DISCLOSURE STATEMENT   Following are important precautions to prevent This equipment is prohibited from use in California damage to unit or merchandise. Please read carefully! with any refrigerants on the “List of Prohibited ...
  • Page 5: Installation Instructions: Skid Removal / Case Alignment, Adjusting & Sealing

    INSTALLATION INSTRUCTIONS: SKID REMOVAL / CASE ALIGNMENT, ADJUSTING & SEALING Installation Note: Units shown may not depict an exact representation of your particular unit being installed. Caution! Do Not Grasp Fold-Down Ledge To Remove From Skid Or move Into Position. 1.
  • Page 6: Installation Instructions, Cont'd: Sealing And Bolting Heated Cases Together

    INSTALLATION INSTRUCTIONS, CONT’D: SEALING AND BOLTING HEATED CASES TOGETHER shown with floating arrowheads below ( ). You Sealing and Bolting Heated Cases Together may need to remove decking, side covers, ‘perf’ Follow these steps to assure a secure, level lineup. panel, etc.
  • Page 7: Operation

    START-UP / LIGHTING / CASE TEMP. / CAREL® iJF PROGRAMMABLE CONTROLLERS / OPERATION 1. Merchandiser Start-Up  Caution: Case Temperature dial reflects internal case temperature ONLY (not product temperature).  Case must be field wired. Use a food probe to determine ACTUAL product ...
  • Page 8: Electrical Connections: Access And Field Wiring

    ELECTRICAL CONNECTIONS: ACCESS AND FIELD WIRING 1. Electrical Connections: Access knockout). Access is now available to programmable controllers, terminal strip, ballasts, A. View of case rear. Power to case must be terminal block, LED, etc. turned off before accessing rear control panel. >...
  • Page 9: Well Heat

    WELL HEAT factory to heat wells at proper temperatures. Well Heat Modifications to these settings should be rare.  Turn on main power switch.  Should programmable controllers need to be  Well heat is controlled by Carel® iJF revised, see CAREL® iJF PLATFORM Programmable Controllers.
  • Page 10: Overhead Ceramic Heaters

    OVERHEAD CERAMIC HEATERS  See Carel® iJF Programmable Controller section Overhead Ceramic Heaters in this manual for specifics.  When main power switch is turned on, overhead  Warning! Disconnect power before providing ceramic heaters are energized. maintenance & service to unit. ...
  • Page 11: Overhead Ceramic Metal Halide Light Fixtures

    OVERHEAD CERAMIC METAL HALIDE LIGHT FIXTURES  As ceramic metal halide lamps may take up to 15 Overhead Ceramic Metal Halide Light Fixtures minutes to gain full illumination, turn on lamps  Warning! Lamps are NOT manufactured to BEFORE loading product into case. This will allow resist breakage.
  • Page 12: Front Glass / Rear Doors / Optional Rear Ledge

    FRONT CURVED GLASS / REAR DOORS / OPTIONAL REAR LEDGE View of Curved 1. Raise the Curved Glass Glass Being Raised View of Rear  To raise the front glass, secure Doors being the lift handle extrusion on the lifted up, bottom edge of the door and pivoted out and lift up.
  • Page 13: Optional Scale Stand

    OPTIONAL SCALE STAND Optional Scale Stand  Scale stand is provided with receptacle which is to be wired separately.  Depending upon order, scale stand Scale Stand may be at either left or right of case. View of Typical Case With Scale Stand and Receptacle Scale Stand Receptacle...
  • Page 14: Removing Pans And Dividers (For Cleaning)

    REMOVING PANS AND DIVIDERS (FOR CLEANING) Removing Pans and Dividers (for Cleaning) 3. Perform cleaning service on pan warmer shield. 4. Replace pan dividers and pans in reverse order they Note: Make certain that unit has been turned off and were removed.
  • Page 15: Cleaning Schedule

    CLEANING SCHEDULE Warnings: 1. DO NOT clean heated wells while hot. Flip Well Heater Switches to OFF position. Allow wells to cool to room temperature before cleaning. 2. Lowering the front glass with items inside top cap can cause damage to case. 3.
  • Page 16: Troubleshooting

    TROUBLESHOOTING System is not operating Check that the utility power is on. Check that the MAIN Power Switch is on. Check the circuit breaker box for tripped circuits. Warmers will not heat Check that temperature controllers (at case rear) are at proper settings.
  • Page 17: Cases Only

    Blend MODEL NRS3648RXV-SAMPLE SERIAL NO. 12345X30DZ098765 888 E. Porter Rd - Muskegon, MI 49441 Harmony Oasis Addenda Reveal Fusion Grocerant Impulse SINGLE PHASE 1.84 AMPS 3048256 120 VOLTS 60HZ Conforms to UL Std. 65 FOR PARTS OR SERVICE CALL...
  • Page 18: Carel® Ijf Platform Programmable Controller For Heated Cases - Page 1 Of 4

    CAREL® iJF PLATFORM PROGRAMMABLE CONTROLLER FOR HEATED CASES - PAGE 1 of 4 1. Introduction  The date provided herein is derived from The CAREL iJF Programmable Controller Material +0300010EN - rel. 1.0 - 10.05.2021 ||| SCC - Revision A Date: 1.19.2022. ...
  • Page 19 CAREL® iJF PLATFORM PROGRAMMABLE CONTROLLER FOR HEATED CASES - PAGE 2 of 4 7. Keypad Overview This data derived from CAREL® Programmable Controller Material +0300010EN - rel. 1.0 - 10.05.2021 ||| User Manual/Carel_iJF Platform_Prog-Cont for Htd Cases_User Manual_4-Pager ||| Rev A Date: 06/22/2022 >...
  • Page 20 CAREL® iJF PLATFORM PROGRAMMABLE CONTROLLER FOR HEATED CASES - PAGE 3 of 4 8. Screen Navigation - User Settings  The figures below show how to navigate between screens on the display for USER SETTINGS only.  Establishing USER SETTINGS are the MOST COMMON reason for needing to navigate the screen. ...
  • Page 21 CAREL® iJF PLATFORM PROGRAMMABLE CONTROLLER FOR HEATED CASES - PAGE 4 of 4 9. Screen Navigation - Factory Settings  The figures below show how to navigate between screens on the display to reset at FACTORY SETTINGS only.  CAREL acronyms: “USt” = User Settings / “CtL” = Control / “FSt” = Factory Settings / “ESC” = Escape / “dir” = Direct Functions / “PSd”...
  • Page 22: Technical Service Contact Information & Warranty Information

    STRUCTURAL CONCEPTS TECHNICAL SERVICE CONTACT INFORMATION & LIMITED WARRANTY YOU MUST HAVE THE FOLLOWING INFO AVAILABLE TECH SERVICE/WARRANTY CONTACT INFO: BEFORE CONTACTING STRUCTURAL CONCEPTS: 1 (800) 433-9490 / EXTENSION 1 SERIAL NO. / MODEL NO. / STORE NO. / STORE DAYS/HOURS AVAILABLE: MONDAY - FRIDAY (CLOSED HOLIDAYS) ADDRESS / DETAILS (PHOTOS, LEAK LOCATIONS,...