Indeeco 110-Z3 Operating Manual page 30

Table of Contents

Advertisement

 
EN 60947-4-1: 2019:
IEC 61000-4-2:2008
IEC 61000-4-3:2006
IEC 61000-4-4:2004
IEC 61000-4-5:2006
IEC 61000-4-6:2008
IEC 61000-4-11:2004
CISPR 11 Group 2, Class A
CISPR11 2015, A1 2016
CISPR11 2009, A1 2010
EN 55011
Name of Authorized Representative: Paul Evalds
Title of Authorized Representative: President
Place of Issue: Lewes, Delaware USA
Date of Issue: March 2, 2022
 
Paul Evalds
Signature of Authorized Representative
www.avatarinstruments.com
Electrostatic discharge immunity
Radiated, radio frequency electromagnetic field immunity
Electrical fast-transient / burst immunity
Surge immunity
Immunity to conducted disturbances induced by radio-frequency fields
Voltage dips, short interruptions and voltage variations immunity
Radiated Emissions & Conducted Emissions – Radio-frequency disturbance
characteristics – Limits and methods of measurement.
CAUTION: This equipment not intended for use in residential or medical environment.
For use in Class B environments, additional external filtering on power lines is required.
Shielded cables may also be needed.
For use with Phase Angle Control, additional external filtering is required to pass Class
A conducted Emissions. A Schaffner filter series FN3270-H or equivalent should be used
as a line input filter with model A1P & A3P Phase Angle Fired SCRs.
A Schaffner FN2080-16-06 was installed at the AC power input during testing to be
CISPR32 CE Class B compliant.
Contact Schaffner EMC, Inc. to find the proper filter for your specific application.
Schaffner EMC Phone (USA) 732-225-9533,
16587 Coastal Highway
Phone 302-703-6865
Fax 302-703-6876
www.schaffner.com
Lewes, DE 19958