TELEMATIC DATA COLLECTOR
TDC-E210
Intended use
Telematic Data Collector: (TDC-E210GC, TDC-E210AC),
referred to as TDC-E below, is gateway unit for SICK sensors
and is used to collect and transfer data from various SICK
sensors to a Cloud.
TDC-E is used to collect the data from sensors on various
Interfaces like Ethernet, CAN, RS-485, RS-422, RS-232, 1-
Wire, Digital inputs and outputs and Analog inputs.
TDC-E and accessories may only be operating in accordance
with their intended use. In the case of any other usage or in
the event of any modifications to the device or to the SICK
software, any warranty claims against SICK AG shall be null
and void.
About this document
This Quickstart document describes the TDC-E for use with
SICK sensors. It contains all the information needed in order
to use the device.
Before starting to work with TDC-E, read this Quickstart
document carefully and make sure that you are familiar with
the device. The information on correct and safe operation of
the system presented here will help you avoid personal injury
or damage to property.
Additional and other applicable documents
For further information on TDC-E and SICK sensors operation,
please refer to the relevant operating instructions.
The TDC-E operating instructions describes the following
aspects in detail:
• Physical interfaces and pinout of all connectors
• Installation
• Operation
• Basic functions
The latest Quickstart document as well as the operating
instructions can be downloaded from the Internet as follows:
8026880 QUICKSTART TDC-EX10XX • 2022/03/15 • Subject to change without notice • SICK AG • Waldkirch • Germany •
Go to https://sick.com/tdc
You will find all the documents and additional
1.
downloads in this section
You can also obtain support from your sales partner.
For your safety
It is essential that TDC-E is transported, stored, installed and
used in accordance with its intended use in order to ensure
error-free, safe operation.
TDC-E may only be installed, operated, used and maintained
by appropriately trained, authorized specialist personnel.
Specialist personnel are individuals who possess the
technical training, knowledge and experience necessary in
order to understand the tasks entrusted to them, evaluate
these and identify possible hazards.
Precautions:
-Do not expose the device to extreme temperature or humidity.
-Do not use or store the device in dusty or dirty areas.
-The antennas shouldn't come in contact with cables, metal
objects, insulation or brackets.
-Do not expose the device to water, rain, splashing water or
spilled drinks. It is not waterproof.
-Do not spray anything on and inside the device.
-Dropping, knocking, violently shaking and any rough handling
may damage the device.
-Do not transport or store flammable gas, liquid or explosives
in the vehicle compartment where the device is installed.
-Before using the device in a vehicle that transports liquefied
petroleum gas (such as propane or butane) ensure that the
vehicle complies with valid fire and safety regulations of state
where the vehicle is used.
-In case of malfunction, contact the authorized service center.
CAUTION
To prevent the risk of electric shock, disconnect power supply
from TDC-E when opening the housing for SIM card
replacement/installation
(if
replacement/installation
needed). Other than that, TDC-E housing does not contain any
user-serviceable parts!
Installation and commissioning
Scope of delivery
The following components and accessories are supplied with
TDC-E:
• Connection cables:
-
WireSet – TDC-E PWR power cable
• LTE antenna
• GPS antenna
• WLAN+WPAN antenna
• Quickstart document
Step 1: Mounting the TDC-E
Device can be mounted on any sufficiently stable support.
To do this, use the mounting holes on the housing of the
device.
Figure 1: TDC-E, dimensions and mounting holes,
(all dimensions in millimeters (inches))
Step 2: Connecting sensors to the TDC-E
Direct connection
is
Connect the sensor communication interface to the
appropriate connection terminal on the TDC-E device. Use the
cables provided with the sensor or additional extension cables
if needed.
Step 3: Installing the power supply
•
The power supply (SELV limited, with exact voltage rating)
may only be installed by a qualified electrician.
• When working at electrical installations, it is essential to
comply with habitual safety requirements.
• If installing in vehicle or on battery, check operating
instructions for special installation requirements
To establish the power supply for TDC-E, use a suitable cable
(WireSet–TDC-E PWR or WireSet–TDC-E PWR+AIN/DIO) to
connect electrical supply to the device's PWR connector (see
Figure 2
).
www.sick.com
TDC-E does not have its own power switch. To switch off the
device, remove the power supply cable from the PWR
connector or disconnect the power supply.
TDC-E features three LED's that show the current operating
state:
State
Green LED
Yellow LED
Device pre-booting
ON
OFF
Device booting
Fast flashing
OFF
Device ready
Hearth beat
OFF
Restoring backup
Fast flashing
Fast flashing
Device reset
Fast flashing
Fast flashing
(factory, data or
system reset)
Software update
Fast flashing
Fast flashing
Device in error state
OFF
ON
User defined under
-
ON/OFF/Heart
'Interfaces' web
beat
page
Step 4: Configuring device
To configure device, access TDC-E Device Manager. TDC-E
Device Manager is a local website on device which is used for
Device Management.
To establish communication with TDC-E, connect TDC-E and
PC using ethernet cable. Make sure that PC is in the same
subnet as TDC-E.
Use any browser (recommended Google Chrome) to access
TDC-E Device Manager, by typing web address to browser's
address bar (example for GbE port0 (Eth0):
https://192.168.0.100).
Create initial user account to manage the device, users or
access your services.
For further information refer to the operating instructions.
Maintenance and cleaning
Maintenance
TDC-E housing does not contain any user-serviceable parts.
Cleaning
Clean the housing with a soft, dry or slightly moistened cloth.
Do not use any solvents or high-pressure cleaners.
TELEMATIC DATA COLLECTOR TDC-EX10XX | SICK
Red LED
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON/OFF/Heart
beat
1
Need help?
Do you have a question about the TDC-E210 and is the answer not in the manual?
Questions and answers