Gashob-/sink-combination
Table of Contents

Advertisement

Available languages

Available languages

CARBEST Gas Hob & Sink Combination | 70177/70176

5.2 Gas connection

CAUTION!
There should be a suitable pressure regulator/reducer compliant with the gas categories used on the
appliance immediately downstream of the gas cylinder or container feeding the system.
A gas shut-o valve or a valve disconnecting the system is installed on the supply line, downstream of
the regulator and immediately upstream of the appliance intended to connect, in a place which can
easily be accessed and inspected.
These instructions also give precise indications for connecting the appliance to the gas and a reference
to the installation regulations in force in the country in which the appliance is to be used.
CATEGORY AND COUNTRIES OF DESTINATION
13B/P(30)
BE, CY, DK, EE, FR, GB, HU, IT, LT, NL, NO,
SE, SI, SK, RO, HR, TR, BG, IS, LU, MT, FI, DE
13 + (28-30/37)
BE, CH, CY, CZ, ES, FR, GB, GR, IE, IT, LT,
LU, LV, PT, SK, SI.
13B/P(50)
AT, CH, SK
MODEL
70177/70176
CAUTION!
During installation and connection, the gas conductor of the appliance must not be subject to twisting,
pulling or other stresses.
The gas pipeline connection to the appliance must be done with a suitable tool to guarantee the
sealing and safety.
GAS PRESSURE
30 mbar Butane (G30)
30 mbar Propane (G31)
28~30 mbar Butane (G30)
37 mbar Propane (G31)
G30 Butane and G31, Propane at 50mbar
NOMINAL AND COMPLETE
HEAT OUTPUT
kW-gr/h
2.8-204
17
VOLUME OF AIR
REQUIRED FOR COMBUSTION
m3 /h
5.6