Emerson White-Rodgers 70 Series Product Overview page 20

Thermostat line extension

Advertisement

Technical Details - Installer Menu Options
Menu
30 CR
Heat Cycle Rate (how often the heat will turn on)
32 CR
Aux Cycle Rate (how often the auxiliary heat will turn on)
35 CR
Cool Cycle Rate (how often the cooling will turn on)
50 CL
Compressor Lockout (protects the compressor from short cycling)
Duel Fuel Logic (turn On when using gas as the auxiliary heat
60 dF
source)
65
Maximum Heat Limit (maximum set point for heat mode)
66
Minimum Cool Limit (minimum set point for cool mode)
Schedule Type (set as either 7-Day, 5-1-1 Day or Non-
74
Programmable)
Early Start (starts heating or cooling early so your programmed
76 E
temperature is reached by the programmed time)
79
Fahrenheit or Celsius
Temperature Display Adjustment (adjust the displayed "Room
81
Temperature")
Continuous Display Light (keep the backlight always on – "C" wire
83 dL
required)
86
Change Air Filter (set up a monthly reminder)
Description
White-Rodgers 70 Series Thermostat Line Extension
Setting
SLOW – slow
MEd
MEd – medium
FAS – fast
SLOW – slow
MEd
MEd – medium
FAS – fast
SLOW – slow
MEd
MEd – medium
FAS – fast
On – 5-minute display
OFF
OFF – no delay
On – gas auxiliary heat
OFF
OFF – electric auxiliary heat
99
47 to 99
45
45 to 97
7 – 7 day
5
5 – 5-1-1 day
0 – Non-Programmable
On – start early
Off
OFF – start at program
°F – Fahrenheit
°F
°C - Celsius
0
-5 to +5
On – always on
OFF
OFF - momentarily
1 to 12 – reminder time
OFF
OFF – no filter reminder
Options
period time
20