Advertisement

Quick Links

Owner's Manual
Original Instructions
Portable air conditioner
Models: KPC05AK-A3NNA1C
KPC05AK-A3NNA2C
KPC05AK-A3NNA2B
K3&$.$11$&
KPC06AK-A3NNA1C
KPC06AK-A3NNA2C
KPC06AK-A3NNA2B
KPC06AK-A3NNA3B
K3&$.$11$&
Thank you for choosing our product.
Please read this Owner's Manual carefully before operation and
retain it for future reference.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KPC05AK-A3NNA1C and is the answer not in the manual?

Questions and answers

Summary of Contents for Kinghome KPC05AK-A3NNA1C

  • Page 1 Owner's Manual Original Instructions Portable air conditioner Models: KPC05AK-A3NNA1C KPC05AK-A3NNA2C KPC05AK-A3NNA2B K3&$.$11$& KPC06AK-A3NNA1C KPC06AK-A3NNA2C KPC06AK-A3NNA2B KPC06AK-A3NNA3B K3&$.$11$& Thank you for choosing our product. Please read this Owner’s Manual carefully before operation and retain it for future reference.
  • Page 2: Table Of Contents

    Content Operation Notices Operation Environment ...................1 Safety Warning ......................2 Part's Name ......................3 Operation Guide Operation Introduction for Control Panel ..............4 Buttons on Remote Controller ..................6 Introduction for Icons on Display Screen ..............6 Introduction for Buttons on Remote Controller ............7 Function Introduction for Combination Buttons ............9 Operation Guide ....................
  • Page 3 Explanation of Symbols Indicates a hazardous situation that, if not avoided, will DANGER result in death or serious injury. Indicates a hazardous situation that, if not avoided, could WARNING result in death or serious injury. Indicates a hazardous situation that, if not avoided, may CAUTION result in minor or moderate injury.
  • Page 4: Operation Environment

    Operation Environment The air conditioner must be operated within the temperature range: 61°F~95°F(16°C ~ 35°C). The appliance is for indoor use only. The appliance must be positioned so that the plug is accessible. This air conditioner can only be used for family, not for commercial industry.
  • Page 5: Safety Warning

    Safety Warning This appliance can be used by children aged from 8 years and above and persons with reduced physical,sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 6: Part's Name

    Part's Name Controller panel Guide louver Swing louver Castor Plug of power cord Filter Air inlet Joint A Heat discharge pipe Joint B+C Remote controller This picture is only for reference. Please refer to the actual product for the appearance. NOTICE: Heat discharge pipe and other installation accessories can't be discarded.
  • Page 7 2SHUDWLRQ ,QWURGXFWLRQ IRU &RQWURO 3DQHO 1DPH RI FRQWURO SDQHO 'ual-8 nixie tube &ool mode indicator + / - button 'ry mode indicator )an mode indicator )an speed indicator MRGH button Sleep button Timer button ON/OFF button Fan button 2SHUDWLRQ RI FRQWURO SDQHO 1RWH After putting through the power, the air conditioner will give out a sound.
  • Page 8: Operation Introduction For Control Panel

    Operation Introduction for Control Panel Mode button Press this button and the mode will circulate according to below sequence: &22/ 'R< FAN COOL: 8QGHU WKLV PRGH FRROLQJ PRGH LQGLFDWRU LV EULJKW 'XDO QL[ie tube displays set temperature. Temperature setting range is 61°F(16°C)~ƒ)(30°C). 'RY: 8QGHU WKLV PRGH GU\LQJ PRGH LQGLFDWRU LV EULJKW 'XDO QL[LH tube won’t display.
  • Page 9: Buttons On Remote Controller

    Buttons on remote controller ON/OFF button MODE button +/- button FAN button X-FAN button SLEEP button TIMER button Introduction for icons on display screen Timer on Timer off Sending signal x-fan operation cool operation sleep operation dry operation lock fan operation set speed Set temperature Set time...
  • Page 10: Introduction For Buttons On Remote Controller

    Introduction for buttons on remote controller Note: When power is connected(stand by condition), you can operate the air conditioner through the remote controller. When unit is on, each time you press the button on remote controller, the sending signal icon " "...
  • Page 11 Introduction for buttons on remote controller Note: 8QGHU $XWR VSHHG DLU FRQGLWLRQHU ZLll VHOHFW SURSHU IDQ VSHHG DXWRPDWLFDOO\ DFFRUGLQJ WR DPELHQW WHPSHUDWXUH )DQ VSHHG FDQ W EH DGMXVWHG XQGHU 'U\ PRGH ;)$1 EXWWRQ 3UHVV WKLV EXWWRQ XQGHU FRRO DQG GU\ PRGH WR VWDUW XS [IDQ IXQFWLRQ3UHVV WKLV EXWWRQ DJDLQ WR FDQFHl [IDQ IXQFWLRQ Note: :KHQ [IDQ IXQFWLRQ LV RQ LI WKH DLU FRQGLWLRQHU LV WXUQHG RII LQGRRU IDQ ZLOO VWLOO...
  • Page 12: Function Introduction For Combination Buttons

    Introduction for buttons on remote controller Note: 5DQJH RI WLPH VHWWLQJ LV aK The interval between two motions can't H[FHHG V RWKHUZLVH WKH UHPRWH FRQ troller will exit setting status. Function introduction for combination buttons Child lock function Press “+” and “-” buttons simultaneously can turn on or turn off child lock function. When child lock function is started up, LOCK indicator on remote controller is ON.
  • Page 13: Operation Guide

    Operation guide $IWHU SXWWLQJ WKURXJK WKH SRZHU SUHVV 212)) EXWWRQ RQ UHPRWH FRQWUROOHU WR WXUQ RQ WKH DLU FRQGLWLRQHU 3UHVV 02'( EXWWRQ WR VHOHFW \RXU UHTXLUHG PRGH: &22/ '5Y )$1 3UHVV  RU  EXWWRQ WR VHW \RXU UHTXLUHG WHPSHUDWXUH THPSHUDWXUH FDQ¶W EH DGMXVWHG XQGHU DXWR PRGH  3UHVV )$1 EXWWRQ WR VHW \RXU UHTXLUHG IDQ VSHHG DXWR ORZ PHGLXP DQG KLJK VSHHG...
  • Page 14: Clean And Maintenance

    Clean and Maintenance WARNING Before cleaning the air conditioner, please turn off the unit and disconnect power. Otherwise, it may cause electric shock. Do not wash air conditioner with water. Otherwise, it may cause electric shock. Do not use volatile liquid (such as thinner or gas) to clean the air conditioner. Otherwise, it may damage the appearance of air conditioner.
  • Page 15 &OHDQ DQG 0DLQWHQDQFH &OHDQ KHDW GLVFKDUJH SLSH Remove the KHDW GLVFKDUJH pipe from air conditioner, clean and dry it , and then UHLQVWDOO LW )RU WKH PHWKRG RI LQVWDOODWLRQ DQG UHPRYDO  SOHDVH UHIHU WR WKH instruction for "Installation and disassembly of heat discharge pipe"). &KHFNLQJ EHIRUH XVHVHDVRQ 1.
  • Page 16: Malfunction Malfunction Analysis

    0DOIXQFWLRQ $QDO\VLV Please check below items before asking for maintenance. If the malfunction still FDQ¶W EH HOLPLQDWHG SOHDVH FRQWDFW ORFDO GHDOHU RU TXDOL¿HG SURIHVVLRQDOV Phenomenon Troubleshooting Solution 3RZHU IDLOXUH" :DLW DIWHU SRZHU UHFRYHU\ ,V SOXJ ORRVH" 5HLQVHUW WKH SOXJ :KHWKHU WKH DLU VZLWFK LV WULS $VN SURIHVVLRQDO SHUVRQ WR Air conditioner SHG RII RU IXVH LV EXUQW"...
  • Page 17 Malfunction analysis Phenomenon Troubleshooting Solution :KHWKHU DLU RXWOHW RU DLU LQOHW LV (OLPLQDWH WKH REVWDFOHV EORFNHG" 8QGHU KHDWLQJ PRGH ZKHWKHU PRELOH XQLW ZLOO VWRS EORZLQJ LQGRRU WHPSHUDWXUH LUHDFKHV IDQ DIWHU UHDFKLQJ VHW VHW WHPSHUDWXUH" WHPSHUDWXUH ,Q RUGHU WR SUHYHQW FROG DLr 1R IDQ EORZHG :KHWKHU KHDWLQJ PRGH LV VWD DLU FRQGLWLRQHU ZLOO GHOD\ IRU D...
  • Page 18 Malfunction analysis Malfunction code 1. Pour out the water inside chassis. 2. If "H8" still exits, please contact professional Chassis is full of water. person to maintain the unit. Malfunction of ambient Please contact professional person to deal temperature sensor. with it.
  • Page 19: Installation Precaution

    Installation Precaution WARNING Observe all governing codes and ordinances. Do not use damaged or non-standard power cord. Be caution during installation and maintenance. Prohibit incorrect operation to prevent electric shock, casualty and other accidents. Selection of installation location Basic requirement Installing the unit in the following places may cause malfuncti on.
  • Page 20: Preparation Before Installation

    Preparation before installation Note: check if the accessories are available before installation. Accessory list heat discharge joint A joint B joint C Adapter pipe window panel wire hook pipe clip rubber plug rain shield washer spring washer drainage pipe pipe hoop bolt support battery...
  • Page 21: Install Wire Hook

    Install Wire Hook Assemble the wire hook at the back of the unit with screws (the direction of wire GLUHFWLRQ RI ZLUH KRRN LV XSZDUG wire hook screw direction of wire hook is downward :LQG WKH SRZHU FRUG DURXQG WKH ZLUH Kook.
  • Page 22: Removing Collected Water

    Removing Collected Water There are 2 ways to remove collected water: Use the continuous drainage option from the bottom hole Note: When using the continuous drainage option from the bottom hole, install drainage pipe before using, otherwise poor drainage will affect normal operation of the unit.
  • Page 23 Removing Collected Water 'UDLQDJH ZD\ DV IROORZV 1. In cooling or drying operation, the condensation water will be drained to the chassis and spattered by water-striking motor. $V WKH WHPSHUDWXUH RI FRQGHQVHU LV KLJK PRVW RI WKH FRQGHQVDWLRQ ZDWHU ZLOO EH HYDSRUDWHG Dnd drained to outdoor.
  • Page 24 Removing Collected Water Use the continuous drainage option from the middle hole Note: Water can be automatically emptied into a floor drain by attaching 14mm inner diameter hose (not included). 1. Remove the continuous drain cap 1 by turning it counter clockwise then remove the rubber stopper 2 from the spout.
  • Page 25: Installation In A Double-Hung Sash Window

    Installation in a double-hung sash window (Note: If the inner width of window is below 20.5"(520mm), please remove the adjusting panel from window panel and then cut the window panel to make its width the same as the width of window.) adjusting panel window panel 1.
  • Page 26 Installation in a double-hung sash window spring washer support washer bolt 5. Fix the rain shield on the support with nuts, spring washer, washer and bolt. screws washer rain shield spring washer 6. Cut the sponge B to a proper length and attach it to the window sash. sponge B (adhesive) 7.
  • Page 27 Installation in a double-hung sash window 7.2 If the inner width of the window is between 20.5"(520mm) and 37.4"(950mm) inclusive. (1) Open the window sash and place the window panel on the window stool. (2) Slide the adjustment panel to fit the window stool width. (3) Secure the window panel to the window stool with screws.
  • Page 28 Installation in a double-hung sash window 9. Close the window sash securely against the Window panel. 10. Cut the sponge A to a proper length and seal the gap between upper part of inner window sash and outer window sash. 11.
  • Page 29 Installation in a sliding sash window window panel joint B+C inner side 3. Fix the protective grille on joint B+C with screws. screws protective grille 4. Fix the support on the outer side of window panel with nuts, spring washer, washer and bolt.
  • Page 30 Installation in a sliding sash window 6. Cut the sponge B to a proper length and attach it to the window stool. sponge B (adhesive) 7. Install the window panel into the window stool. 7.1 If the heigth of the window is less than 20.5"(520mm). The window panel cannot be installed in windows less than 20.5"(520mm) high.
  • Page 31 Installation in a sliding sash window 7.3 If the inner width of the window is between 37.4" (950mm) and 56.7" (1440mm) inclusive. (1) Attach the extension panel to the adjustment panel. (2) Open the window sash and place the window panel on the window stool. (3) Slide the adjustment and extension panels to fit the window stool height.
  • Page 32 Installation in a sliding sash window 10. Cut the sponge A to a proper length and seal the gap between left side of inner window sash and outer window sash. 11. Fix the inner window with window bracket and screw, so that it can not slide horizontally.
  • Page 33: Installation In A Sliding Sash Window

    Installation and Disassembly of Heat Discharge Pipe Install heat discharge pipe 1. Rotate joint A clockwise into the heat discharge pipe. heat discharge pipe Join A clockwise . Install anather side of heat discharge pipe clockwise into protective grille sub-assy. Heat discharge pipe clockwise Join A...
  • Page 34 Installation and Disassembly of Heat Discharge Pipe Note of Installingheat discharge pipe The discharge pipe is suggested to be installed according to below figure by the manufacturer. under 51 inchs correct about 24 inchs User can adjust the installation method of the discharge pipe basing on the requirement, while the similar installation methods as below which will lead to unsmoothly air-out are not allowed.
  • Page 35: Operation Test

    If ambient temperature is below 61°F(16°C), the unit can't operate in cooling mode. Electric Schematic Diagram The Electric schematic diagram are subject to change without notice. Please refer to which one on the unit, KPC05AK-A3NNA2B、KPC05AK-A3NNA1C、KPC05AK-A3NNA2C、.3&$.$11$& .PC06AK-A3NNA2B、.PC06AK-A3NNA3B...