Page 1
Set up and installation should be performed by qualified installation personnel. Keep area around appliances free and clear from combustibles. PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE. THE MONTAGUE COMPANY 1830 Stearman Avenue P.O. BOX 4954 HAYWARD,CA 94540-4954 TEL: 510/785-8822 FAX: 510/785-3342...
Page 2
CONTENTS INSTALLATION ………. 3 MAINTENANCE ………….. 9 OPERATION ……………8 SERVICE ………………… 10 RENEWAL PARTS ……….11 IMPORTANT WARNING: Improper installation, adjustment, FOR YOUR SAFETY: alteration, service or maintenance can cause property damage, injury Do not store or use gasoline or or death. Read the operating and other flammable vapors...
Page 3
INSTALLATION The MONTAGUE cheesemelters are produced with the best possible materials and work- manship. PROPER INSTALLATION IS ESSENTIAL FOR SAFE AND EFFICIENT TROUBLE- FREE OPERATION. The gas fired cheesemelter is manufactured for use with the type of gas indicated on the nameplate.
Page 4
INSTALLATION PROVISIONS MUST BE MADE FOR ADEQUATE AIR SUPPLY TO THE UNIT. VENTILATING HOOD The cheesemelter(s) must be installed under a properly designed ventilating hood. The hood should extend at least 6‖ beyond all sides of the unit. The hood should be connected to an adequate mechanical exhaust system.
Page 5
INSTALLATION Adequate clearance for service and proper operation must be provided at the front, top, sides, and back. The combustion air openings are provided in the front of the unit and must not be obstructed. CAUTION DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND VENTILATION AIR TO THE CHEESEMELTER.
Page 6
INSTALLATION Lift the cheesemelter assembly above the range and slide the Figure 2 vertical posts into position on the range body. (See Figure 2) RANGE MOUNTED MODELS CM24, CM36, CM48, CM60, CM72 Any of these cheesemelters may be mounted on a reinforced high shelf on any (G, VG)26, (G, VG)2626, (G, VG)260, (G, VG)2616, (G, VG)1626, G16, G160, G016, G0, and G00 Series, provided that the cheesemelter section is not more than 4 inches wider than the range over which it is mounted.
Page 7
INSTALLATION INSTALLATION REMOVE CONTROL PANEL AND TOP PANEL FOR ACCESS TO GAS CONNECTION Before connecting the cheesemelter to the gas supply line, be sure that all new piping has been cleaned and purged to prevent any foreign matter from being carried into the controls by the gas.
OPERATION THIS APPLIANCE HAS BEEN CLASSIFIED AS COMMERCIAL COOKING EQUIPMENT AND MUST BE OPERATED BY QUALIFIED AND/OR PROFESSIONAL OPERATING PERSONNEL. CAUTION DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND VENTILATION AIR TO THE CHEESEMELTER. KEEP THE APPLIANCE AREA FREE AND CLEAR FROM COMBUSTIBLES.
MAINTENANCE CARE AND CLEANING GENERAL CLEANING Lint and grease suspended in the air tend to collect in passages. Therefore, air openings, flueways, and primary air openings, etc., should be periodically cleaned to prevent clogging. The complete cheesemelter should be given a periodic general cleaning. DAILY: Remove grid rack, drip shield (below grid rack) and grease container.
SERVICE WHEN SERVICE IS NEEDED, CONTACT A LOCAL SERVICE COMPANY, DEALER, OR FACTORY TO PERFORM MECHANICAL MAINTENANCE AND REPAIRS. THESE INSTRUCTIONS ARE INTENDED FOR USE BY COMPETENT SERVICE PERSONNEL. CAUTION TURN OFF GAS AT MANUAL SHUT OFF VALVE NEXT TO THE APPLIANCE BEFORE ATTEMPTING TO LOOSEN ANY GAS CONNECTIONS.
SERVICE MODEL CM SERIES CHEESEMELTER RENEWAL PARTS ITEM PART NO. DESCRIPTION 01019-7 Burner Pilot Assy— Nat. Gas 01020-0 Burner Pilot Assy— Propane Gas 01000-6 Valve, Pilot 09308-4 Burner Assy w/ Nat. Gas Orifice (28 1/4) 09314-9 Burner Assy w/ Propane Gas Orifice (28 1/4) 09321-1 Burner Assy w/ Nat.
Page 12
In order to establish full compliance with Proposition 65, we attached a yellow warning label to each gas fired unit manufactured by the Montague Company. Carbon monoxide would not be present in concentrations that would pose a "significant risk" to the consumer when the equipment is installed, operated and maintained as follows: 1.
Page 13
When ordering parts, to eliminate mistakes and facilitate delivery, always give the following information: Serial No. _____________________________________________ Model No. _____________________________________________ Change No. ____________________________________________ Name & No. of Part Model No. Change No. Serial No. The Montague Company 1830 Stearman Avenue P.O. Box 4954 Hayward, CA 94540-4954 11591-6 6/98...