Figure 5
IMPORTANT: Never pry with the bit.
If you are breaking rebar reinforced concrete, use
a chisel bit in the breaker to cut through the
rebars in the concrete. The rebar can also be cut
with a torch.
IMPORTANT: Do not use the breaker in or
under water.
Breaking a Vertical Surface
Converting the Breaker
1.
Tilt the breaker as far forward as possible and
lower it until the tip is resting on the ground.
2.
Remove the click pin securing the front
mounting pin (Fig. 6).
3.
Drive the front mounting pin out of the breaker
(Fig. 6).
4.
Lower the loader arms until the holes in the
breaker align with the upper holes in the mount
(Fig. 6).
5.
Drive the front mounting pin through the upper
holes and secure it with the click pin (Fig. 6).
m–4250
2
1. Click pin
Operating Tips for Vertical Surfaces
Position the bit on the vertical surface in the
same manner as you would position it on a
horizontal surface.
Maintain pressure on the bit by driving the
traction unit forward into the vertical surface
while operating the breaker.
2
1
Figure 6
2. Front mounting pin
Operation
1
m–4251
9