4. CONFIGURATION

Using internal jumpers J1 to J8, we can configure the following
parameters:
Input impedance (If the input has a transformer it must be
configured in LOW IMPEDANCE).
Separation of the cable shield from the circuit ground.
Each one of the two inputs incorporates a jumper that
allows separating the cable shield from the circuit ground
connection.
PHANTOM power supply. Optional. When ordered, the
inputs may be separated to supply 24 VDC PNANTOM type
power. Model T700 transformer is used for sensitivities
between 0 dB and -20 dB. For sensitivities of -60 dB,
Transformer T752 is used along with an XLR connector for
the input.
The VOX priority control is configured via dipswitch SW200.
CONFIGURATION JUMPERS J1 to J8
*HIGH
INPUT
IMPEDANCE
LOW
SHIELD-
*JOINED
GROUND
SEPARATED
CONNECTION
*DISABLED
ENABLED
PHANTOM
(Transformer T752
POWER SUPPLY
and sensitivity of -60
(24VDC)
dB)
ENABLED
(Transformer T700
and sens. 0 dB /-20
dB)
SW200. VOX CONTROL PRIORITY ON/OFF
ON
INPUT A
* OFF
ON
INPUT B
*OFF
SW200. DEACTIVATION TIME
OF THE VOX CONTROL PRIORITY
*SHORT (~2 sec) OFF ON
INPUT A
LONG (~5 sec)
*SHORT (~2 sec)
INPUT B
LONG (~5 sec)
UMX-EA3 version 3.2.000
UMX-EA3
INPUT A
INPUT B
J3
OFF
J6
J3
ON
J6
J8
ON
J7
J8
OFF
J7
J1
OFF
J4
J2
OFF
J5
J1
ON
J4
J2
OFF
J5
J1
OFF
J4
J2
ON
J5
SW1 SW2
ON
OFF
ON
OFF
SW3 SW4 SW5 SW6
ON OFF
OFF ON
ON OFF
PHANTOM POWER SUPPLY WITH T700 (0dB/-20dB)
ALIMENTACIÓN PHANTOM CON T752 (-60dB)
OFF
ON
ON
OFF
OFF
OFF
*
FACTORY SETTINGS
ON
OFF
OFF
ON
2 Audio inputs card
SW200
J1
J2
J3
J8
J7
J4
J5
J6
6

Advertisement

Chapters

Table of Contents
loading

Table of Contents