Titon CME3.1 Q Plus Product Manual

Extract ventilation unit with humidity sensor and auralite/controller connection
Hide thumbs Also See for CME3.1 Q Plus:

Advertisement

Quick Links

Product Manual
Product Manual
EN
)
CME3.1 Q Plus
TP 342CH
Extract Ventilation Unit with Humidity Sensor and auralite/controller connection
ventilation systems

Advertisement

Table of Contents
loading

Summary of Contents for Titon CME3.1 Q Plus

  • Page 1 Product Manual Product Manual CME3.1 Q Plus TP 342CH Extract Ventilation Unit with Humidity Sensor and auralite/controller connection ventilation systems...
  • Page 2: Warnings, Safety Information And Guidance

    Warnings, Safety information and Guidance Warnings, Safety information and Guidance Important Information Read these instructions fully before the installation of this appliance 1. Installation of the appliance and accessories must be carried out by a qualified and suitably competent person and be carried out in clean, dry conditions where dust and humidity are at minimal levels.
  • Page 3: Explanation Of Symbols On The Appliance

    Explanation of symbols on the appliance Symbol Definition Read instruction Manual. Risk of Electric Shock. General hazard safety alert. Wait until all machine components have completely stopped before touching them. Disconnect the mains supply before removing this cover. Disconnect the mains supply before removing this cover.
  • Page 4: Table Of Contents

    Contents Contents Warnings, Safety information and Guidance Important Information � � � � � � � � � � � � � � � � � � � � �2 Explanation of symbols on the appliance� � � � � � �3 Product Overview Package Contents�...
  • Page 5: Product Overview

    Product Overview Product Overview This manual is for the Titon CME3.1 Q Plus Extract ventilation unit. The CME3.1 Q Plus unit is designed for continuous extract ventilation of multiple rooms, for example bathrooms, kitchens, utility areas and toilets. The unit uses a highly efficient backward curved centrifugal impeller coupled to a high efficiency EC motor.
  • Page 6: Dimensions

    Dimensions This diagram details the overall size of the unit and the additional space required around the unit to allow for commissioning and future servicing and maintenance 72.5 Service Void Ports Ø125 All Dimensions in mm DO NOT BOX IN UNIT...
  • Page 7: Component Identification

    Component Identification Lid Screw Scroll Top Output Port Base Cable Clamps Port Cover...
  • Page 8: Product Features

    Product Features CME3.1 Q Plus CH The CME3.1 Q Plus CH is controllable by various volt-free switches and sensors. Mains switching can be achieved by use of the Titon Boxed Relay 5A TP 505. Mains switching Volt free switching Continuous Speed The normal running speed of the unit.
  • Page 9: Remote Indicator Panel Or Control Connection

    CME3.1 Q Plus CH Setback Switching Is enabled by connection of a latching volt-free one-way switch, or combined with the Boost Speed with the 3 position switch TP 508. Integrated The units are fitted with an Integrated Humidity Humidity Sensor Sensor.
  • Page 10 LED ventilation system status indicator, designed to fit a standard UK patress or recessed backbox. The indicator is for use with specific Titon CME units. The indicator has six LEDs which display Setback Normal...
  • Page 12: Installation

    Any orientation is possible. connection of the Output Port to Outside. Ø125mm or Ø100mm ducting is used Locate a site for mounting the Titon CME3.1, for connection to the other ports. take into consideration the position of: A minimum distance of 200mm The rooms to be ventilated between the CME3.1 unit and any...
  • Page 13: How To Convert The Port Cover

    How to convert the Port Cover 14. Ø125mm ducting fits inside the units Duct Ports. To enable the Port Cover to be used 15. Ø100mm ducting fits inside the as an adaptor for 100mm ducting, use Convertible Port Cover. a small screwdriver to tear out the tail 16.
  • Page 14: Wiring

    Wiring Wiring The supply connection to this unit is via screw terminals mounted on the printed circuit board (PCB), access is achieved by removing the PCB Cover. To remove the PCB cover remove the two small retaining screws and the cover will lift. After supply connection has been made and before powering up the unit the PCB cover MUST be refitted and screwed in place, do not overtighten screws.
  • Page 15 SWITCH POSITIONS 1 - Setback Speed 2 - Continuous Speed 3 - Boost Speed TP 508 Three position rotary switch Three position Rotary Switch TP 508 switching and connection Volt-free setback switching of the unit’s controller PCB using single- pole latching switch and / or volt-free normally open relay contacts To avoid the unit being inadvertently left in Setback Mode, it is recom-...
  • Page 16 Volt-free boost switching of unit’s controller PCB using single-pole switches TP 502, TP 503, TP 507 and/or TP500 / TP501 Humidistat. TP500/TP501 There maximum of 10 single pole switches or humidistats that can used. Boost switching and External Humidistat connection +V(5V) +V(5V) Connection of auralite...
  • Page 17: Cable Retention

    Cable Retention Cable Clamps Ensure the supply cable and if used control cable are routed via the cable clamp and securely held in place. The Cable Clamp Bar can be removed and turned over and used to clamp thinner cables.
  • Page 18: Commissioning

    Commissioning Commissioning The fan speeds of the Titon CME3.1 Q Plus CH will require adjustment to ensure that the flow rates achieved provide adequate ventilation. The Titon CME3.1 Q Plus CH has 3 standard fan speed settings, Continuous Speed, Boost Speed and Setback Speed.
  • Page 19: Commissioning Controls

    To place the unit into commission mode Return Commissioning Switch to Run Position to exit commissioning. move the Commissioning Switch to the Program Position. The CME3.1 Q Plus CH will automatically switch between Setback After commissioning the Commissioning Speed, Continuous Speed and Boost Speed Switch must be placed in the when adjusting the respective potentiometer.
  • Page 20: Boost Overrun

    Boost Overrun Boost Overrun is variable between 0 and 30 minutes. Program / Run Header Link Boost Overrun Pot positions Rotate potentiometer to change overrun time. Boost Overrun adjustment can be done at any time without the need to move the Commissioning Switch. Humidity Sensor The Humidity Sensor’s trigger point is variable from 55%RH to 85%RH.
  • Page 21: Reset Information

    Reset Information Controller Reset Following a controller reset the ventilation system will need to be fully re- commissioned. The unit will need to be powered up during the reset procedure. Place the Commissioning Switch in the Run Position Rotate the Continuous Speed and Boost Speed adjustment fully clockwise.
  • Page 22: Technical

    Titon Hardware Ltd. Supplier Address 894 The Crescent Colchester Business Park Colchester Essex CO4 9YQ Model CME3.1 Q Plus CH Central Mechanical Extract Model Identifier TP342CH Declared Typology NRVU - UVU Type of Drive installed Multi-speed drive Type of heat recovery system...
  • Page 23: Maintenance

    Routine maintenance All ventilation units require periodic maintenance. Routine maintenance must only be carried out by a suitably qualified and competent person. The CME3.1 Q Plus must be periodically cleaned internally. The maximum time between cleaning will depend on the local environment.
  • Page 24: Removal Of The Scroll Top

    Removal of the Scroll Top Cleaning Interior The Scroll Top is retained with six clips, For best results use a clean damp cloth some units may also use four screws. with a warm mild detergent solution. To remove the Scroll Top first remove and retain the screws (if fitted).
  • Page 26: Service Record

    Service Record Serviced By Company Name Date Notes...
  • Page 27: Installed

    Product Manual must be kept in the Home Information Pack and used as a service record. MARK E TING DIVISION 894 The Crescent, Colchester Business Park, Colchester, CO4 9YQ Tel: +44 (0) 1206 713800 Fax: +44 (0) 1206 543126 Email: ventsales@titon.co.uk Web: www.titon.com...
  • Page 28 ©2022 TITON DO 5791 Issue 03...

This manual is also suitable for:

Tp 342ch

Table of Contents