USER MANUAL
XS4 CODE LOCKER
The XS4 Code Locker provides a convenient security solution for
many different lockers, cabinets, boxes etc. Achieve simple access
through the keypad, without the need for a network connection.
Codes can be assigned and can be active for a specified time
period. It is easy to install and can be programmed via your mobile
phone.
The battery pack, electronic components and the locking
mechanism are all located on the inside off the door to prevent
vandalism and sabotage.
www.saltosystems.com
XS4 CODE LOCKER
L
50
K
Publications of SALTO SYSTEMS S.L. are protected by copyright and all rights are reserved.
SALTO SYSTEMS publications may not be reproduced in any form or by any means without written permission from the copyright owner

Advertisement

Table of Contents
loading

Summary of Contents for Salto XS4

  • Page 1 XS4 CODE LOCKER Publications of SALTO SYSTEMS S.L. are protected by copyright and all rights are reserved. SALTO SYSTEMS publications may not be reproduced in any form or by any means without written permission from the copyright owner...
  • Page 2: Table Of Contents

    CONTENT 1. Installation Page 3 2. Access Page 3 2.1 Fixed user PIN codes Page 3 2.2 Free assignment PIN codes Page 4 2.3 Timed PIN codes Page 4 2.3.1 Configuring timed PIN codes Page 5 3. Fixed user PIN codes management Page 6 3.1.
  • Page 3: Installation

    2.1. Fixed User PIN Codes User PIN’s are allocated in the internal device memory. The XS4 Code Locker can retain up to 200 fixed codes from 4 to 8 digits long. Each individual user has their own PIN code to operate the locker.
  • Page 4: Free Assignment Pin Codes

    2.2. Free Assignment PIN Codes Free assignment PIN code mode allows users to use any available locker just by using any PIN code to capture the locker and use the same PIN code to open and release the locker. Open and close by any 4 to 8 digits code. The code is erased every time the lock is opened, making it available for a new user.
  • Page 5: Timed Pin Codes

    Generated to grant access for 1, 2, 3 or 4 hours from the user defined start time. 2.3.1 Configuring Timed PIN Codes If you want to configure the XS4 Code Locker manually, you will need to configurate both the time, date and seed code to activate the timed PIN codes function. Please see the “Time and Date configuration”...
  • Page 6: Fixed User Pin Codes Management

    3. FIXED USER PIN CODES MANAGEMENT User codes can be changed, added, and deleted. Each user code is stored in a specific addressed internal memory position (from 1 to 200). Each user code position must be kept track of. Keep a record of the position number and the user name in the Web Application or another registering tool.
  • Page 7: Add Fixed Pin Codes

    3.1 Add fixed PIN codes Insert 1 to start adding users. Enter: A confirmation beep will sound and the yellow LED will flash. To add users, first insert a position to place the new PIN code (between 1 and 200). Example: If a valid position is inserted, the Yellow LED will light solid, and the green LED will blink until the fixed user PIN code...
  • Page 8: Configuration

    4. CONFIGURATION The service configuration code is used to authenticate and access the configuration menu, which is needed to configure the Code Locker. Service Configuration Menu Insert the Service Configuration Code (12347890 is factory default) Enter: A confirmation beep will sound and the green LED will flash.
  • Page 9: Change User Configuration Code

    4.3 Change User Configuration Code Enter: A confirmation beep will sound and the red LED will light. The keypad is ready to receive a new User Configuration Code. Insert a code that is between 4 to 8 digits. Example: A confirmation beep will sound and the green LED will flash.
  • Page 10: Special Functions

    4.5 Special functions Enter: A confirmation beep will sound and the yellow LED will light. The keypad is ready to ENABLE/DISABLE the following special configurations. Enter the number of the respective option to toggle the Special Function’s state. Silent mode, audio advices can be enabled or disabled.
  • Page 11: Time And Date Configuration

    ON. The keypad is now ready to receive the date and time configurations. For every configuration a LED visual confirmation will be shown. Please note when entering the time that the XS4 Code locker runs by a 24 hour clock. 1. Insert the year (e.g.: 2022)
  • Page 12: Seed Code

    4.7 Seed Code Thee Seed Code is an 8 digit random number needed to generate online Timed PIN Codes. If manually inserted, you have to keep track of the code and use it to generate valid Timed PIN Codes online. Only Low security codes can be generated with a custom user Seed Code.
  • Page 13: Enable Web App Configuration

    Whith this WebApp you can add devices, users and configurations to your XS4 Code Locker. Find our WebApp at: https://codelocker.app Enter: A confirmation beep will sound and all the LED’s will light.
  • Page 14: Battery Monitoring

    Low Battery Three long beeps will sound after entering a valid code, and the red LED lights. The XS4 Code Locker will still be able to open after the warning signal has been performed. Very Low Battery Three long beeps will sound after entering a valid code, and the red LED lights.
  • Page 15: Hardware Factory Reset

    6. HARDWARE FACTORY RESET Check the Installation Manual to open the battery holder on the XS4 Code Locker. To reset the hardware to factory default, please follow the below steps: 1. Ensure the locker is closed or the ‘White and Black’ pair of cables next to the button are disconected.
  • Page 16: Technical Specifications

    7. TECHNICAL SPECIFICATIONS Outside cover measures: 55,4 x 138,8 x 29,2 mm. Inside cover measures: 100 x 110,5 x 25 mm. Deadbolt projection: 15 mm. Power source: 3 alkaline batteries (LR03 AAA 1,5V). Optional 3 Lithium batteries (FR03 - AAA 1,5V). Number of openings: Up to 2 years (depending on usage).