Holtek CPCB48MIO0001A Reference Manual

Ht-ice interface card

Advertisement

Quick Links

HT-ICE Interface Card
Reference Manual
January 2005
Copyright  2005 by HOLTEK SEMICONDUCTOR INC. All rights reserved. Printed in
Taiwan. No part of this publication may be reproduced, stored in a retrieval system, or
transmitted in any form by any means, electronic, mechanical photocopying, recording, or
otherwise without the prior written permission of HOLTEK SEMICONDUCTOR INC.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CPCB48MIO0001A and is the answer not in the manual?

Questions and answers

Summary of Contents for Holtek CPCB48MIO0001A

  • Page 1 Reference Manual January 2005 Copyright  2005 by HOLTEK SEMICONDUCTOR INC. All rights reserved. Printed in Taiwan. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or...
  • Page 2: Table Of Contents

    Contents Contents Introduction....................1 CPCB48MIO0001A Interface Card ..............2 CPCB49C000001A Interface Card..............4 CPCB46SER0001A Interface Card..............5 TPCB47C00-A-1 Interface Card ..............7 TPCB47C100000A Interface Card ..............8 TPCB95SER0000A Interface Card ..............9 TPCBG2190-A Interface Card..............10 TPCB23B60-A-1 Interface Card ..............11 TPCB86SER0000A Interface Card ..............12 TPCB82K680000A Interface Card ...............13 CPCB82K960004B Interface Card ..............14...
  • Page 3: Introduction

    Note that as new devices are continually being released by Holtek, which may require new interface cards, for the latest information it is suggested that the Holtek website is consulted.
  • Page 4: Cpcb48Mio0001A Interface Card

    For more information, refer to the chapters on Breakpoint and Trace the Application Program within the Holtek HT-IDE3000 User′s Guide. The JP1 connector provides the I/O port connections as well as other pins. The DIP...
  • Page 5 CPCB48MIO0001A Interface Card The U1 to U9 connectors are used for different MCUs whose assignment is shown in the following table. SOCKET SUPPORTED IC HT48R10A-1, HT48C10-1 (24 pins) HT48R30A-1, HT48C30-1 (24 pins) HT48R30A-1, HT48C30-1, HT48R50A-1, HT48C50-1 (28 pins) HT48X37-24 HT48R06A-1, HT48C06, HT48R05A-1, HT48C05 (18 pins)
  • Page 6: Cpcb49C000001A Interface Card

    JP5, provide a means for external signals to trigger the internal breakpoint and trace functions. For more information, refer the chapters on Breakpoint and Trace the Application Program within the Holtek HT-IDE3000 User′s Guide. Connector JP2 is used for the HT49R30A-1/HT49C30-1 devices with 48-pin packages while connector JP3 is used for the HT49R50A-1/HT49C50-1 devices with 48-pin packages.
  • Page 7: Cpcb46Ser0001A Interface Card

    CPCB46SER0001A Interface Card CPCB46SER0001A Interface Card This interface card, which is used in conjunction with the CICE46C00CCEA, includes the following functions: • External clock source • A/D converter HT46V00 or HTUY0001 in location U5 • MCU pin assignments, I/O, LCD common and segment output connections J P 1 J P 2 V R 1...
  • Page 8 CPCB46SER0001A Interface Card The JP5 connector provides the LCD common and segment outputs while the JP6 connector provides the I/O port connections as well as other pins. The sockets at locations U2, U3 and U4 are used for other purposes by different MCUs. Their assignments are shown in the following table.
  • Page 9: Tpcb47C00-A-1 Interface Card

    TPCB47C00-A-1 Interface Card TPCB47C00-A-1 Interface Card This interface card is used in conjunction with the TICE47C-CCDA J P 1 J P 3 V R 1 V R 2 J P 2 The external clock source has two modes, RC and Crystal. If a crystal clock is to be used, positions 2 and 3 should be shorted on JP1 and a suitable crystal inserted into location Y1.
  • Page 10: Tpcb47C100000A Interface Card

    TPCB47C100000A Interface Card TPCB47C100000A Interface Card This interface card is used in conjunction with the TICE47C100000A V R 1 R C I N R R E F R S E N VR1 is used to adjust the LCD voltage, VLCD. Two operating voltage sources can be selected, an internal 1.5V or external 1.5V.
  • Page 11: Tpcb95Ser0000A Interface Card

    TPCB95SER0000A Interface Card TPCB95SER0000A Interface Card This interface card is used in conjunction with the TICE95SER0000A Switch S1 is used to simulate a low voltage condition, a situation which can be detected internally by the HT95L400/40P, HT95L300/30P, HT95L200/20P and HT95L100/10P devices. When switch S1 is pressed, the low battery flag (LBFG; bit 4 of LCDC register) will be set, resulting in a simulated low battery condition.
  • Page 12: Tpcbg2190-A Interface Card

    TPCBG2190-A Interface Card TPCBG2190-A Interface Card This interface card is used in conjunction with the TICEG2190-CCAA J P 1 J P 2 J P 3 V R 1 V R 2 C O N 3 C O N 4 The external clock source has two modes, RC and Crystal. If a crystal clock is to be used, positions 2 and 3 should be shorted on JP1 and a suitable crystal inserted in location Y1.
  • Page 13: Tpcb23B60-A-1 Interface Card

    TPCB23B60-A-1 Interface Card TPCB23B60-A-1 Interface Card This interface card is used in conjunction with the TICE23B60-CCXA V R 1 VR1 is used to adjust the LCD voltage, VLCD. The J1 connector provides the LCD common and segment outputs while the J2 connector provides the I/O port connections as well as other pins.
  • Page 14: Tpcb86Ser0000A Interface Card

    TPCB86SER0000A Interface Card TPCB86SER0000A Interface Card This interface card is used in conjunction with the TICE86SER0000A J P 1 V R 1 J P 2 V R 2 L S 1 L S 2 The external clock source has two modes, RC and Crystal. If a crystal clock is to be used, positions 2 and 3 should be shorted on JP1 and a suitable crystal inserted into location Y1.
  • Page 15: Tpcb82K680000A Interface Card

    TPCB82K680000A Interface Card TPCB82K680000A Interface Card This interface card is used in conjunction with the TICE82K680000A. The card should be plugged into the CN1 connector of the HT-ICE. J P 1 V R 1 J P 2 The external clock source has two modes, RC and Crystal. If a crystal clock is to be used, positions 2 and 3 should be shorted on JP1 and a suitable crystal inserted into location Y1.
  • Page 16: Cpcb82K960004B Interface Card

    CPCB82K960004B Interface Card CPCB82K960004B Interface Card This interface card is used in conjunction with the CICE82K960004A U 1 4 L E D 1 U 1 2 L E D 2 L E D 3 • HT-IDE3000 Configuration Option description: USB joystick: When the ADC function is to be used, the ″Enable joystick mode″ must be selected.
  • Page 17 CPCB82K960004B Interface Card • Target board interface description: For interfacing to the user target board a choice of five connectors, U4, U5, U12, U14 and J7 are provided. • Diagnose description: − Within the HT-IDE3000, select TOOL\Diagnose, then press the reset switch on the HT-ICE in accordance with the instructions.
  • Page 18: Cpcb82M990004A Interface Card

    CPCB82M990004A Interface Card CPCB82M990004A Interface Card This interface card is used in conjunction with the CICE82M990004A L E D 1 U 1 2 L E D 2 L E D 3 • HT-IDE3000 Configuration Option description: Sys Freq: Do not select the ″Internal″ option. This is because the ICE system frequency is determined by the Interface Card settings.
  • Page 19 CPCB82M990004A Interface Card • Diagnose description: − Within the HT-IDE3000, select TOOL\Diagnose, then press the reset switch on the HT-ICE in accordance with the instructions. − Select Test All to enter the HT-ICE self-diagnostics. When the system enters the IO EV1 section, the message ″Press ′RESETB′ to test USB Connection″ will appear.