Troubleshooting - QUIK CORP RFR Series Instruction Manual

Rfr upgradeable fire hose reels
Table of Contents

Advertisement

Troubleshooting

Problem
Reel does not retract.
and manual button does
not work
Reel does not retract and
manual button works
Reel only retracts at a
close distance.
Reel is hard to pull out
Turbo 400 leaks.
Probable Cause
Switch (1) not "on" or
faulty
Flat battery
Break in vehicle battery
connection
Blown fuse.
Broken reel drive
Transmitter and receiver
not tuned
Discharged transmitter
battery
Wrong transmitter
Faulty receiver or
transmitter
Discharged transmitter
battery
Aerial broken or loose on
base
Coax broken inside of
aerial base
Low 12V. Or 24V power
source
Faulty receiver or
transmitter.
Interference from
overhead power lines
Reel brake is adjusted
to tight
Worn seat or seal in
handle.
www.qcfe.com.au
Remedy
Switch on or replace
Charge or replace
Repair
Replace (10 amp)
Replace
Tune radio as per in-
structions on next page
Replace (216-9V)
R=right L=left
Return to factory
Replace (216-9V)
Tighten or replace
Repair
Charge battery
Return to factory
Adjust brake
Replace. Kit No. 5175