AirTech UT150SC Installation And Wiring Instructions

Advertisement

UT150SC/B
Installation and Wiring Instructions

SAFETY AND GUIDANCE NOTES

All wiring to be in accordance with the current I.E.E.
Regulations, or the appropriate standards of your country and
MUST be installed by a suitably qualified person.
The Fan should be provided with a local isolator switch
capable of disconnecting all poles, having a contact
separation of at least 3mm.
Ensure that the mains supply (Voltage, Frequency, and
Phase) complies with the rating label.
The Fan should only be used in conjunction with the
appropriate Airtech products.
The fan should only be used in conjunction with fixed wiring.
When the Fan is used to remove air from a room containing a
fuel-burning appliance, ensure that the air replacement is
adequate for both the fan and the fuel-burning appliance.
The Fan should not be used where it is liable to be subject to
direct water spray for prolonged periods of time.
Where ducted Fans are used to handle moisture-laden air, a
condensation trap should be fitted. Horizontal ducts should be
arranged to slope slightly downwards away from the Fan.
This appliance is not intended for use by persons (including
children)
with
capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of
the appliance by a person responsible for their safety.
Young children should be supervised to ensure that they do
not play with the appliance.
This product should not be disposed of with household waste. Please recycle where facilities exist. Check with
your local authority for recycling advice.
reduced
physical,
IP65
sensory
or
mental

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UT150SC and is the answer not in the manual?

Questions and answers

Summary of Contents for AirTech UT150SC

  • Page 1 Phase) complies with the rating label. The Fan should only be used in conjunction with the appropriate Airtech products. The fan should only be used in conjunction with fixed wiring. When the Fan is used to remove air from a room containing a fuel-burning appliance, ensure that the air replacement is adequate for both the fan and the fuel-burning appliance.
  • Page 2 DESCRIPTION DESCRIPTION Radon mitigation fans are used with under-floor extract and ventilation systems designed to remove the gas from underneath the floor of a house and vent it into the atmosphere through a pipe. Radon is measured in becquerels per cubic metre of air (Bq m3) and Public Health England (PHE) has set the UK Action Level for radon at 200 Bq m3.
  • Page 3 WIRING WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING THE INSTALLATION / OR MAINTENANCE. IMPORTANT Solid core cable must be used. The cross - sectional area of supply cord used should be ranged from 1 -2.5mm The wiring MUST be enclosed in conduit/trunking.
  • Page 4 Notes AIRTECH ENVIRONMENTAL SYSTEMS STATHE ROAD, BURROWBRIDGE, SOMERSET, TA7 0RY Tel : 0800 378 017 EU Authorised Representative: Airtech Solutions Bedrijvenweg 17 7442 CX Nijverdal Nederland authorisedrep@airtechsolutions.nl 476526 B 0422...

This manual is also suitable for:

Ut150b