Sanyo XMS1272 Technical & Service Manual page 11

Dc inverter multi-system air conditioner
Hide thumbs Also See for XMS1272:
Table of Contents

Advertisement

XMS1272 & PNR-XS1872
Indoor Unit
Type
Voltage Rating
Total Capacity
Air Circulation (High)
Moisture Removal (High)
Available Voltage Range
Running Amperes
Power Input
Controls / Temperature Control
Control Unit
Timer
Fan Speeds
Airflow Direction (Indoor)
Air Filter
Refrigerant
Operation Sound
Refrigerant Tubing Connections
Refrigerant
Tube Diameter
Accessories
Wired Remote Controller (Option)
Dimensions & Weight (Indoor Unit)
Unit Dimensions
Package Dimensions
Weight
Shipping Volume
Remarks: Rating conditions are:
Cooling: Indoor air temperature
Outdoor air temperature 95°F D.B. / 75°F W.B.
ft
/min (m
3
-
Horizontal
Vertical
Indoor : Hi/Me/Lo
Narrow tube
inch (mm)
Wide tube
inch (mm)
Height
inch (mm)
Width
inch (mm)
Depth
inch (mm)
Height
inch (mm)
Width
inch (mm)
Depth
inch (mm)
Net
Shipping
cu.ft (m
80°F D.B. / 67°F W.B.
Semi-Concealed Type Indoor Unit
BTU/h
kW
/h)
3
Pints/h
V
A
W
Microprocessor / I.C. Thermister
Wireless Remote Control Unit
24-Hour ON or OFF Timer, 1-Hour OFF Timer
Indoor
dB-A
Indoor Unit
(XMS1272 & PNR-XS1872)
12-5/16
(313)
24-19/32
(625)
24-19/32
(625)
-
-
-
Ib. (kg)
41.3
(18.7)
Ib. (kg)
-
)
-
3
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
11
208V Single-Phase 60Hz
Cooling
11,900
3.5
235 (400)
4.26
187 to 253
0.12
16
-
Auto and 3 steps
-
Auto
Washable, Anti-Mold
R410A
34 / 32 / 31
Flare Type
1/4 (6.35)
3/8 (9.52)
Air Clean Filter
STK-RCS-7TWSUA
Individual Unit
Body
(XMS1272)
11-5/32 (283)
22-5/8 (575)
22-5/8 (575)
11-13/32 (290)
24-13/16 (630)
28-1/8 (714)
35.3 (16)
41.9 (19)
4.59 (0.13)
<208V>
Panel
(PNR-XS1872)
1-9/16 (40)
24-19/32 (625)
24-19/32 (625)
4-1/8 (105)
26-3/16 (665)
26-11/16 (678)
6.0 (2.7)
7.7 (3.5)
1.65 (0.04)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xms0972Xs1872Pnr-xs1872