Content Introduction ..............................4 Safety warnings ............................... 6 Installation ................................ 7 Checking the delivery ............................7 Unpacking the UPS system ..........................7 Checking the accessories ..........................8 Installation and setup ............................8 Functions and controls ..........................10 Communication and interfaces ........................11 USB interface ..............................
YUNTO offers the following advantages: • Compact design • Silent operation • Cold start function, starts the UPS system without network voltage • Intelligent battery management, self test and fast charge function Figure 1: YUNTO 500 - 800 Figure 2: YUNTO 1200 - 1500 • Surge protection for data and telephone wires • Alarm function • USB interface • Built-in wall mount • I nc. shutdown, management and monitoring software, DataWatch to download for all operating systems • 24h advance replacement within warranty...
Safety warnings Installation This manual contains important instructions that you must follow during the installation and maintenance 3.1 Checking the delivery of the UPS system and the batteries. Please read all the instructions in the manual before working with the device. Keep the manual in a safe place. Keep the transport box and the packaging material for the carrier or sales point. If parts of the system have been damaged in transit, submit a transport damage complaint to your supplier within 24 hours. If you only CAUTION discover damage after accepting the device, please submit a complain for concealed damage. • T he UPS system carries life-threatening voltages. All repair and maintenance work must be carried out 3.2 Unpacking the UPS system by customer service personnel. • T he UPS system has its own energy source (batteries). The output of the UPS system can be live even when the UPS system is not connected to a wall outlet. CAUTION Unpacking the UPS system at a low ambient temperature can lead to the formation of condensation • I n order to reduce the risk of fire or electric shock, the UPS system may only be installed in buildings inside and outside the casing.
Table 1: Package contents 1. Press the button on the UPS system until a short beep sounds and the status LED lights up. 2. T he UPS system is starting, the display then shows the battery statues (see Chapter 4 > Battery statuses) Description YUNTO 500 YUNTO 800 YUNTO 1200 YUNTO 1500 and supplies the loads connected with reliable power. USB interface cable 3.
IN connection on the reverse of the UPS system. Connect the OUT connection to the end device. The data connection protection cable protects networks with a transfer rate of 10 to 1000 Mbit/s. Figure 3: Control panel and display 5.3 DataWatch software The YUNTO series is supplied as standard with DataWatch, the comprehensive software solution for shutdown Table 2: Descriptions of display and management of the PC or server system and for monitoring the YUNTO and the power supply network. To ensure you are always working with the latest version of DataWatch, please download it from the download area of > www.online-ups.com. Switch / LED Function Alarm DataWatch works in the background and is in constant communication with the YUNTO via the USB protocol. Switch on/off The most famous of all functions: Automatic data backup including the shutdown of running applications and the proper shutdown of the whole system by means of a freely configurable shutdown routine. At the same Normal operating mode: time, DataWatch has a comprehensive messaging system, time-controlled test routines and event logging.
6.4 Disposing of the old batteries or UPS system 6.2 Storage Find out from a local recycling centre how the old batteries or the UPS system should properly be disposed of. If you intend to store the UPS system for an extended period, charge the battery every three months by con- Old batteries can also be returned to ONLINE for disposal free of charge. Please contact Support (see Chapter 8 necting the UPS system to the supply network for five hours. The system should be stored in a cool, dry place. > Support). 6.3 Replacing the batteries CAUTION • Batteries must not be burnt. There is risk of explosion.
Charge the battery for at least 8 hours. The battery is worn through age Replace the battery or faulty. (see > Chap. 6.3). ONLINE sets great store by reliable support and service. The UPS system is not switched on. Press the ON button. The UPS system is overloaded. Check whether the total load exceeds • Free direct advice and support on: Permanent alarm beep and red the capacity of the UPS system.