Ensure the mains voltage matches the voltage marked on the nameplate. Ensure the device is provided with its own power supply line and electric fuse. akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
Page 4
To avoid damage to the device, keep the device in the warm environment for at least 1 hour before powering on. akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
1 - Micro-USB programming interface 2 - service button 3 - two plug positions of terminal block Fig. 2.1 External design akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
Page 6
When the device is powered from USB, the display brightness is by 50% reduced com- pared to 24 V power supply. akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
The parameters in this group define the physical layer of data exchange over the RS485 port for all operating modes. akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
Safe state timeout countdown (Tab. 4.2). If there is no response from the Slave during Safe state timeout, the Master switches to the safe state (Sect. 4.3.1). akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
= 2) – the received variable is not displayed because the data TYPE from registers 59 - 60 is required, but register 60 is not requested akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
The flowchart that describes the display behavior depending on other parameters is shown in the Fig. 4.1. Fig. 4.1 Display operation flowchart akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
(-999… 9999). In this way, values with a number of digits greater than 4 can be dis- akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
Device settings > Displayed value, set the test value of the selected data type in the corresponding row and click the toolbar icon Write parameters akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
Additionally, a value upper limit and a hysteresis can be set for zones 1…4. Open the node Device settings > Extended control. akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
Page 16
> 0 Zone 1 Zone 5 Upper limit: Upper limit: 9999 Hysteresis: Color: green Color: yellow Blinking: Blinking: akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
Page 17
If the variable is decreased, the zone 1 is active in the range [-999; 90), the zone 2 – in the range [90; 130), the zone 5 – in the range [130; 9999]. akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
There is no password by default. If you forgot the password, restore the factory settings (Sect. 6). akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
Restart device − After a pop-up message about successful restart, the device will operate with the default parameters. akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
The device should be cleaned with a damp cloth only. No abrasives or solvent-containing cleaners may be used. akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
Check the device for transport damage and completeness! Report the transport damage immediately to the shipper and akYtec GmbH. akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
The test voltages shown in Fig. A.1 correspond to the tests carried out under normal operating conditions with 1-minute exposure time. akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...