Akytec SMI2 User Manual

Rs485 display
Hide thumbs Also See for SMI2:

Advertisement

Quick Links

SMI2
RS485 Display
User guide
SMI2_2017.09_0250_EN
© All rights reserved
Subject to technical changes and misprints
akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 ·
www.akytec.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SMI2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Akytec SMI2

  • Page 1 SMI2 RS485 Display User guide SMI2_2017.09_0250_EN © All rights reserved Subject to technical changes and misprints akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
  • Page 2: Table Of Contents

    D.2 Error codes .............................. 10 D.3 Segment addressing ..........................10 D.4 Symbol presentation ..........................10 D.5 Example ..............................11 akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
  • Page 3: Safety Guidelines

    30 g Protection class Ambient temperature -40…+70 °C Storage temperature -25…+70 °C Humidity up to 80% (non-condensing) Galvanic isolation akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
  • Page 4: Functional Description

    The SMI2 is designed for switch panel mounting in a borehole of Ø22.5 mm (see Appendix A for dimensions). Fig. 5.1 Mounting akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
  • Page 5: Programming

    The display order corresponds to the register number from the Table D3, column 2. The RESET button must be pressed for a short time again to terminate the display of parameters. akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
  • Page 6: Factory Settings" Mode

    For data types Int and Word the transmitted values are displayed with the set decimal point position (parameter dP). Table 6.1 Decimal point position Parameter dP Display Factor ---- ----. ---.- --.-- -.--- akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
  • Page 7: Alarm Logic

    9 Scope of delivery – SMI2 – Gasket – Mounting nut – User guide – CD with configuration software akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
  • Page 8: Appendix A. Dimensions

    A PLC or a PC with an RS232/485 converter and/or USB/RS485 converter can serve as a master in the RS485 network. There may only be one master in a RS485 network. akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
  • Page 9: Appendix D Functions And Data Transfe

    (2 Bytes) 0…16…2047 0 – Modbus ASCII Protocol read/write 1 – Modbus RTU Byte t.Pro 2 – akYtec akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
  • Page 10 1 – flashing on ind.M Actual state of the display Char [4] 36-37 see ***) read only segments (4 bytes) akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
  • Page 11: Error Codes

    D.3 Segment addressing Table D6 Segment D.4 Symbol presentation Table D7 ASCII code and the symbol presentation ASCII- Code – – akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...
  • Page 12: Example

    0x04 (4) Data length (byte): 0x08 (8) Data: 0x57(W) 0x2E(.) 0x4F(O) 0x2E(.) 0x52(R) 0x2E(.) 0x44(D) 0x2E(.) CRC: 0x90 0x31 akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de...