Metal box with built-in electronic keypad (2 pages)
Summary of Contents for Hiltron security POWER8E
Page 1
POWER8E Antintrusion central unit 8 with GSM integrated INSTALLATION AND USE MANUAL...
Page 2
POWER8 - Installation and use manual security Introduction 1.1 Functional characteristics Anti-theft central unit 2 delayed zones+ 6 zone immediates + 24 line + tear-resistant tamper and anti-opening. 8 input zones and 24h line programmables individually logic, balanced or radio. Output for activation external devices on connection/disconnection of the central unit.
Page 3
Installation security Installation General warnings To installthe centralin closed place not exposed to the extreme temperatures and intemperie. To a fixing solide and sure it’s necessary to ensure that the mounting surface it’s plain. To position the central unit in a point that operates in the interior of the box easily. To prefer to insert the cables connection to the external devices in the box of the central unit and through the hole placed on the bottom of the box, preparing a root canal under track.
Page 4
POWER8 - Installation and use manual security Cables of power supply To insert the cable (red and black) derived fromthe power supply on the box. To crimp the conductor grounding on the eyelet supplied and to insert the eyelet in the closing screw of cable clamp.
Page 5
Installation security 2.4 Description of the connections + INT output present with the system inserted, to be used for the activation of the telephone dialer. -12V+ 12V auxiliary output protected by fuse. RS485 OUTPUT A RS485 OUTPUT B S.A./GND/Sir 10A exchange relay output to be used for activating external sirens.
Page 6
POWER8 - Installation and use manual security DXR1 radio receiver module connection The POWER8 control panel requires a DXR1 radio transceiver module to use the XR200-XR152-XR300 wireless sensors and sirens. SETUP +INT -12V+ A B S.A. GND Sir 24H GND Z1 Z2 Z3 Z4 GND Z5 Z6 Z7 Z8 Receiver 1 DXR1 ADDRESS 32...
Page 7
Installation security DXR1 radio receiver module connection Position the tamper card so that the tooth on one of the short sides of the circuit is inserted inside the slot on the bottom of the container and match the hole on the other side with the hole on the edge of the container. Make sure that the microswitch at the bottom of the tamper board is closed by the head of the screw protruding from the bottom of the container, otherwise adjust the protrusion of the screw by screwing or unscrewing it.
Page 8
POWER8 - Installation and use manual security Console connection The POWER8 control unit requires a console for programming and its operation. Below is a connection diagram for DXTOUCH / DX22 console. SETUP +INT -12V+ A B S.A. GND Sir 24H GND Z1 Z2 Z3 Z4 GND Z5 Z6 Z7 Z8 CONSOLE...
Page 9
Installation security Connection of DX200 / DX300 RFID key readers The POWER8 control panel accepts 4 readers with: ID 16 for the first and ID 17 for the second, ID18 for the third and ID19 for the fourth. SETUP +INT -12V+ A B S.A. GND Sir 24H GND Z1 Z2 Z3 Z4 GND Z5 Z6 Z7 Z8 Lector 1 DX200 Add.
Page 10
POWER8 - Installation and use manual security Wired sirens connection SETUP +INT -12V+ A B S.A. GND Sir 24H GND Z1 Z2 Z3 Z4 GND Z5 Z6 Z7 Z8 In series with the24h line electronics siren self-powered siren...
Page 11
Installation security 2.10 Connection of magnetic sensors and detectors SETUP +INT -12V+ A B S.A. GND Sir 24H GND Z1 Z2 Z3 Z4 GND Z5 Z6 Z7 Z8 Detector Z3 Delayed Logic 3300ohm Resistance long short wires long short wires wires wires Magnetic...
Page 12
POWER8 - Installation and use manual security 2.11 Telephone card and GSM antenna With the power off and the battery disconnected, a nano-SIM phone card must be inserted into the SIM holder, respecting the direction as shown in the figure, taking care to disable any PIN and PUK codes with a mobile phone.
Page 13
Installation security 2.12 Recording of the initial message Connect the battery and power up the control unit by activating the disconnector previously set up.The console indicates that the 24H is not activated and no alarm cycle has started. (After a reset, the 24H protection is activated only after the control unit recognizes the closure of the 24H line and the tampers of the control unit and console).
Page 14
POWER8 - Installation and use manual security 3 Programmation Before making the control unit operational, it is advisable to set some operating parameters and enter the telephone numbers of the users who will receive the alarm calls. These operations can be done using the console to access the Programming menu. The POWER8 control unit has two access codes, the first to access programming: <SETUP code>...
Page 15
Programmation security 3.2 Telephone book 3.2.1 Entering Telephone Numbers in the Address Book In the programming menu, use the keys to select 3 1 Y G S M O P E R A T O R 1 - T e l e p h o n e B o o k and confirm with , or enter the SETUP code followed by The display indicates:...
Page 16
POWER8 - Installation and use manual security 3.2.2 Deleting telephone numbers from the Address Book Open the directory menu again and use the keys to select: T E L E P H O N E B O O K D e l e t e N u m b e r s Confirm your choice and use the keys to select the position in the directory and the number to be deleted.
Page 17
Programmation security Setup To activate the Setup menu, in the programming menu, use the and keys to select: 3 1 Y G S M O P E R A T O R 2 - S e t u p and confirm with , or enter the SETUP code followed by With the keys it is possible to select one of the options of this menu:...
Page 18
POWER8 -Installation and use manual security 3.3.1 Write key NOTE: before writing the keys, enable the DX200 / DX300 readers (par.3.3.13) Select this option from the Setup menu: W r i t i n g K e y to write the code stored on the control unit inside an RFID key Type The display shows: W A I T I N G W R I T I N G...
Page 19
Programmation security 3.3.3 New key code This option replaces the key code stored in the control panel with a new one N e w K e y C o d e Confirm the choice with and the display will briefly show: G E N E R A T E D C O D E The new code is stored in the control panel and must be written in all the keys that must work on the control panel.
Page 20
POWER8 - Installation and use manual security 3.3.5 Entry Time and Exit Time The entry time is the time available to the user to access the protected areas and disarm the system before the alarm signals are activated. During this time, any detection of the sensors placed on the delayed protection zones (zone 1 and 2) will not cause alarms and will not activate the alarm memory.
Page 21
Programmation security 3.3.6 Alarm duration The duration of the acoustic signals both on the sirens and on the DX300 readers (if enabled) can be set between 180 and 600 seconds (from 3 to 10 minutes). The duration of the 24h alarm signal with the system disarmed is instead fixed at 180 seconds. In the Setup menu select: A l a r m D u r a t i o n 1 8 0...
Page 22
POWER8 -Installation and use manual security 3.3.8 Logic / Balanced / Radio zones This option allows you to change the operation of the zone inputs and to signal the radio zones. Select this option from the SETUP menu with the keys Z o n e L o g / B a l / R f >...
Page 23
Programmation security 3.3.9 Partial plant A and B This option allows you to set the zones to be included / excluded from surveillance when the control panel is partially armed. Using the keys , to scroll the SETUP menu up to the item: I m p .
Page 24
POWER8 - Installation and use manual security 3.3.10 Arming from remote control This option is used to select which type of arming will be performed by the two button remote controls (DXR20 / XR20) I n s . r e m . c o n t r o l Total arming I m p i a n t o T o t a l Use the key...
Page 25
Programmation security 3.3.11 Volume of the Beep Inserter DX300 The acoustic volume of the buzzer on the DX300 readers can be adjusted on two levels: High and low. Select the option in the Setup menu: B e e p I n s e r t e r >...
Page 26
POWER8 - Installation and use manual security 3.3.13 Activation on alarm of the DX300 key reader buzzer (buzzer in alarm) On DX300 readers it is possible to enable the buzzer to signal the control panel alarm. In the Setup menu select: a l a r m b u z z e r >...
Page 27
Programmation security 3.3.14 RADIO code The 18-digit binary code (a sequence of "0" and "1") that can be programmed and displayed in this section is the one used by the POWER8 and that must be set in all the radio devices that you want to connect to the control panel.
Page 28
POWER8 - Installation and use manual security 3.3.15 Devices on RS485 bus In addition to the console, two connectors and a communication module can be connected to the RS485 “DX bus”. The console cannot be disabled and must always be present, while the two connectors and the Link Module must be enabled / disabled to be managed correctly by the control unit.
Page 29
Programmation security and below: M o d u l e L I N K 1 N O T A c t i v e using to change its status. All the devices connected on the DX bus signal both the lack of enabling and the communication error with a particular flashing of the LEDs.
Page 30
POWER8 - Installation and use manual security 3.3.17 Operation of output + INT The POWER8 control unit has a + INT output on the terminal board which can be used to control external equipment. This output is managed by the control unit and has +12 V. (maximum 100mA) with the system connected or no voltage with the system disconnected.
Page 31
Programmation security 3.3.19 GSM module ignition To turn off the telephone module, select in the Setup menu G S M M o d u l e Type to change the setting: G S M M o d u l e O f f Type to turn the module back on.
Page 32
POWER8 - Installation and use manual security IMEI number of the telephone module (mains power supply status: N e t w o r k O K At the end, key to return to the Programming menu. N O N e t w o r k System reset It closes the telephone communications, forcing the restart of the GSM module and the control panel.
Page 33
Programmation security Setup delete This command is used to restore the factory configuration. Select with the keys in the Programming menu: 3 1 Y G S M O p e r a t o r 5 - C a n c e l l a S e t u p and type or after the SETUP code type...
Page 34
POWER8 - Installation and use manual security Telephone call test This feature is useful for checking the telephone line. Select in the Programming menu with the direction keys 3 1 Y G S M O p e r a t o r 6 - T e s t C h i a m a t a and confirm with or immediately after the SETUP...
Page 35
Programmation security Initial message The initial message is a short audio message (about 10 seconds) recorded by the user which can be used to recognize which system an alarm call is coming from. To record or listen to the message again, access the control panel card and then open the container. To avoid starting an alarm cycle when the control unit container is opened, it may be useful to exclude the 24H zone.
Page 36
POWER8 - Installation and use manual security Commands Access to the commands menu 8 8 4 8 8 4 With the system armed or disarmed, enter the USER code (default followed by to access the commands menu. The first menu option that appears depends on the status of the control unit.With the system disconnected, the following appears on the display: 3 1 Y G S M O p e r a t o r 7 - T o t a l E n t r y...
Page 37
Commands security 8 8 4 Stop cycle Stops the alarm cycle of the sirens and the telephone module and closes any calls in progress.Select on the second line of the console display: 2 8 Y C a l l … 1 - S t o p C Y c l e and confirm with or enter the USER code followed by...
Page 38
POWER8 - Installation and use manual security Then it goes back to showing the command menu options: 3 1 Y G S M O p e r a t o r 2 - U S E R C o d e If the entered code cannot be accepted (same as the SETUP code), the display shows: W R O N G C O D E 8 8 4...
Page 39
Commands security 8 8 4 Activation of output + INT On the POWER8 control unit there is a terminal board output (+ INT) which can be used to turn on external electronic equipment such as heating boilers, telephone communicators, light or acoustic signals.The presence of the control voltage (12v 100mA max) can be controlled automatically by the control unit with the presence of the voltage upon insertion of the system or upon direct command of the user both from the console and remotely via GSM telephone connection.
Page 40
POWER8 - Installation and use manual security 8 8 4 Total armed With the system disarmed, in the commands menu select the command with the direction keys 2 8 Y G S M O p e r a t o r T o t a l I n s e r t e d and confirm the choice with or enter the USER...
Page 41
Commands security 8 8 4 Partial Arming A and B The POWER8 control unit allows two partial arming modes according to diagrams A and B set during the configuration phase. The zones excluded from arming due to partitioning are not monitored by the control panel and do not generate any alarms.
Page 42
POWER8 - Installation and use manual security 8 8 4 System disconnection This command disarms the system and cancels any alarm cycles in progress.. Enter the USER code followed by Select the command with the keys: 2 9 Y G S M O p e r a t o r 0 - D i s a b l e d and key to confirm disarming, or after the USER code key...
Page 43
Commands security SMS, alarm calls and remote control During an alarm cycle, the control unit sends an alarm SMS and calls the first number entered in the directory. When answered, it plays the initial recorded message, useful for the contacted user to identify from which system the call is coming, followed by information on the alarm status and on the power supply status of the control panel.
Page 44
POWER8 - Installation and use manual security Alarm calls For each alarm cycle, the control unit contacts the users in the directory starting with the one entered as the first number.If the user does not answer or does not activate the remote control (thus confirming that it has received the notification) the control unit ends the attempt and continues with the second number in the directory and so on.
Page 45
Commands security Remote access (with GSM communication) Remote access can take place either by calling the control panel number directly or, during aalarm cycle, when the control unit calls a number from the directory. During an alarm cycle, when the call starts from the control panel, before requesting the codeaccess, the control unit starts playing the initial message recorded by the user.
Page 46
POWER8 -Installation and use manual security 5.4.1 Voice menu commands 0 - DISARM This command is listed only when the control panel is armed and is used to disarm the control panel.After executing the command, the voice guide indicates the new status of the control unit. <System disarmed>...
Page 47
Commands security 6 - OUTPUT ACTIVATION This command is available only if the + INT output is programmed to operate on an ON / OFF command. Typing the voice guide indicates: <Output not active, press to activate or press asterisk to return to the menu previous.
Page 48
POWER8 - Installation and use manual security Use of the control panel To program and use the control unit, it is necessary to be equipped with a console. Below is the figure and description of the DXTOUCHB console: DISPLAY SIGNALING GREEN KEYBOARD SIGNALING...
Page 49
Use Central security Signals on the display During normal operation the POWER8 provides some information on the panel display eof the console regarding the status of the system, and of the GSM module. GSM module. The information relating to the GSM connection appears on the first line of the display and is of the type: G S M O p e r a t o r The number next to the flashing antenna symbol represents the signal strength from 0 (min) to 31(max), followed by the indication of the telephone company to which you are connected.
Page 50
POWER8 - Installation and use manual security ACTIVE output - + 12v is present on the + INT terminal of the control unit due to the output activation command. Total Inserted - Total inserted system. Imp Inserted P-A - System inserted with partitioning scheme A. Imp Inserted P-B - System inserted with partitioning scheme B.
Page 51
Use Central security Commands 6.3.1 - Implant insertion From the console it is necessary to check that the immediate zones are not open and, if necessary, close doors and windows or leave the rooms monitored by the sensors that keep the zone alarmed. The opening of the delayed zones does not prevent arming of the control panel, but it is necessary that at the end of the programmed exit time the closure of the delayed line is re-established.It is possible to exclude the zones individually from the exclusion menu.
Page 52
POWER8 -Installation and use manual security 6.3.2 Disarming From the console it is necessary to enter the USER code, select the menu: I M P : E N A B L E D 0 - D I S A B L E D press the or button G S M O P E R A T O R I M P...
Page 53
Use Central security 6.3.4 Output activation When the output is programmed for "ON / OFF command" operation (see paragraph 3.3.17 èIt is possible to control the output both from the console and from the telephone. Enter the control panel USER code followed by the display shows: O U T : D i s a c t i v .
Page 54
POWER8 - Installation and use manual security 6.4.1 Delayed zone 1 and 2 When the system is armed, the activation of zones 1 and 2 not excluded starts a timer set with the programmed entry time. Closing the zone does not interrupt the timing, at the end of which the control unit starts the alarm signals (sirens, SMS messages and telephone calls).
Page 55
Use Central security 6.4.4 Alarm memory The opening of the zones with the control unit armed and the opening of the 24h line and the tampering with the control unit armed or disarmed, in addition to generating an alarm cycle, activates the alarm memory, signaled by the flashing of the red LED on the connectors of the connectors and of the LED blue on the console.
Page 56
POWER8 - Installation and use manual security Operation of GSM communication The indications on the status of the GSM dialer are shown on the first line of the control panel display If the display shows: I N S E R T S I M I m p D i s a b l e d It is necessary to insert a telephone SIM card, and remove any blocking codes (PIN or PUK) from the SIM using a common mobile phone.
Page 57
Use Central security 6.5.1 Remote Control During a phone connection,it’s possible to command the central unit sending the tones DTMF from the phone pad. The activtion of the remote control can occur or during a call alarm of the central unit or calling directly tne number of the SIM of the central unit.
Page 58
POWER8 - Installation and use manual security ELECTRONIC KEY DX200 With the readers DX200 it’s possible to read the PX keys and to execute following operations: - To connect the installation into modality TOTAL, PARTIAL A and PARTIAL B. - Disconnect the installation. - To read or to write new keys.
Page 59
Use Central security TOTAL CONNECTION 1 - To approach the key to the reader Exit Time 2 - When the led visualize the correct recognition Greeen Led (Valid Key) to get away the key to connect the installation. Red Led The Led will visualize the temporisation of EXIT.
Page 60
POWER8 -Installation and use manual security 6.6.2 Others signalisations on the connector Green Led Alarm installation: Red Led 1 sec. Green Led Alarm memory to the central unit disconnected: Red Led 1 sec. Immediate opened zones to the central unit Green Led disconnected: Red Led...
Page 61
Use Central security 6.7 Proximity reader DX300 With the readers DX300 it’s possible to read the keys "KEY" and to execute following operations: - Connect installation in the TOTAL, PARTIAL A and PARTIAL B mode. - Diconnect installation. - To read or to write new keys "KEY" Also through the display of 7 segments it’s possible: - To visualize the modality with to connect the installation.
Page 62
POWER8 - Installation and use manual security "d" with 2 alternate points + "8". Alarm 24H to the central unit disconnected. "E" with 2 alternate points + "8". - Alarm 24H to the central unit disconnected with excluded zones . "segment that rotates"...
Page 63
Use Central security 6.7.3 Further indications on the DX300 Absence connection If communication with the control unit is interrupted, the animation appears on the display of the connector: Waiting for connection During the connection with the control unit, an animation appears for a few moments on the display: Once the connection has been made, the status of the control unit is shown on the display.
Page 64
POWER8 - Installation and use manual security Addressing error If the control unit does not recognize the address set on the connector or on the control unit the connector itself among the 485 devices is not enabled, the display will show the animation: Privacy mode If you program on the control unit that the reader must hide the information (Setup->...
Need help?
Do you have a question about the POWER8E and is the answer not in the manual?