Phason FC Series User Manual

Advertisement

Quick Links

FC-1T-1VDC user manual
The FC-1T-1VDC has a 0 to 10 VDC signal output and a disconnect relay that allows you to easily and effectively
control up to 10 variable frequency drives, slave units, modulating valves, or other equipment that requires a DC
signal.
The knob allows you to easily move between and adjust settings, while the programming lights show which settings
you are editing. The two LED displays show temperatures, signal output, programming information, and alarm
codes.

Features

Temperature-based control with extended range:
−13 to 125°F (−25 to 51°C)
Variable 0 to 10 V output
Capacity for up to 10 devices
Disconnect relay for start/stop signal
Alarm relay (for external alarm system or siren)
3-second full-power-turn-on to minimize fan ice-up
Status and programming LEDs

Installation

Switch OFF the power at the source before connecting the
incoming power wires.
DO NOT switch on the power until you have finished all
wiring and verified all equipment is properly connected and
free of obstructions.
Electrical ratings
Input
120/230 VAC, 50/60 Hz
Signal output
0 to 10 VDC, 2K Ω load
5A at 250 VAC; 5A at 30 VDC, resistive load
Disconnect relay
2A at 250 VAC; 2A at 30 VDC, inductive load
0.4 A at 125 VAC; 2 A at 30 VDC, resistive load
Alarm relay
0.2 A at 125 VAC; 1 A at 30 VDC, inductive load
FC-1T-1VDC
Error code display
Power-failure protection (will not lose settings)
6-foot temperature probe, extendable to 500 feet
Rugged NEMA 4X enclosure (corrosion resistant,
water resistant, and fire retardant)
cCSAus approval
2-year limited warranty
1 / 8
32741000

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FC Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Phason FC Series

  • Page 1 FC-1T-1VDC user manual The FC-1T-1VDC has a 0 to 10 VDC signal output and a disconnect relay that allows you to easily and effectively control up to 10 variable frequency drives, slave units, modulating valves, or other equipment that requires a DC signal.
  • Page 2 For applications that use single-phase, permanent split capacitor (PSC) motors, the FC-1T-1VDC can control the motors using a triac-based slave with DC input, such the Phason FanDRIVE. The FC-1T-1VDC can also control electronically commutated motors (ECMs) using its 0 to 10 VDC output.
  • Page 3 Select the temperature unit The FC-1T-1VDC can operate in either degrees Fahrenheit (°F) or Celsius (°C). The default is Fahrenheit. Locate the pins in the top-left corner of the circuit board. UNITS For Celsius, place the jumper on the top two pins. ...
  • Page 4 Connect an alarm system An alarm system can be a siren, an alarm panel, or an auto-dialer. See your alarm siren’s installation guide for installation instructions and information about the type of system, normally open normally closed If you are connecting the alarm system to a network of controls and your system uses a normally open ...
  • Page 5 When the temperature is between the , fan speed increases or decreases proportionally set point differential  with the temperature. When the temperature is at or above the , the fan runs at full speed. differential  When the temperature is above the , the alarm relay activates, the LED lights up, and the high alarm...
  • Page 6 Manual mode Manual mode allows you to override the automatic settings. Manual mode is useful for testing equipment or other special situations. 1. Press the encoder knob until P a r displays. 2. Turn the knob clockwise until the LED for Alarm is lit. 3.
  • Page 7 Incorrect incoming power wiring Correct the wiring.   Display showing unusually high or The probe is not a Phason probe. Remove the probe and then install a Phason    low temperature probe. The extension cable connected to the Check the extension cable connection and re- ...
  • Page 8 100 percent free of defects. Even reliable products can experience occasional failures and the user should recognize this possibility. If Phason products are used in a life-support ventilation system where failure could result in  loss or injury, the user should provide adequate back up ventilation, supplementary natural ventilation, or an independent failure-alarm system.

This manual is also suitable for:

Fc-1t-1vdc

Table of Contents