Page 1
100 HD Industrial Vacuum Cleaner Wet/Dry Electric Read this manual completely and understand the Operator’s Manual instructions before operating the machine. 100 HD “English Version”...
Blower No. - _______________________________ Installation Date - ___________________________ USER MANUAL ROOTS philosophy is to continually improve all of its products. For this reason we may modify the design, appearance and engineering of our products periodically. Therefore, some changes, modifications and improvements may not be covered in this manual.
It is designed to clean and collect solid/liquid non-flammable materials in an indoor environment. Use only recommended filters/accessories. Do not use this machine in any other way other than described in this Operator’s Manual. 100 HD...
TECHNICAL SPECIFICATIONS Technical Specification - 100 HD - DRY Model 100HD DRY 100HD DRY HEPA Unit Description Value Value Voltage V/Hz 345 - 415 / 50 345 - 415 / 50 Phase Power (Output) Vacuum Pressure 3790 3790 mm of H...
Page 7
TECHNICAL SPECIFICATIONS Technical Specification - 100 HD - WET & DRY Model 100HD WET & DRY 100HD WET & DRY HEPA Unit Description Value Value Voltage V/Hz 345 - 415 / 50 345 - 415 / 50 Phase Power (Output)
Maintenance jobs must always be performed with the Ÿ power plug detached from the power point. The employer must inform and train the user according to Ÿ the provisions of applicable laws. 100 HD...
Page 9
(fuels, solvents, etc.) operating cycle can be checked every time there are doubts. Do not vacuum corrosive substances unless the machine is In the event of this manual being lost or damaged ask Roots Ÿ equipped with containers suitable for this purpose.
Page 10
Ÿ The machine must not be used unless the power cord is in As necessary proper condition. Ÿ Use only original extension cables, with maximum admissible length of 25 m. Ÿ When using or replacing power cords, it is necessary to adhere to as specified by the manufacturer. 100 HD...
Page 11
To move the machine use the large handle (c). Ÿ For greater convenience, the most frequently used Ÿ accessories can be placed in the accessory tray (d). 100 HD...
Page 12
Read the Operator’s General Warning Caution Ecological Hazard Manual Do Not Use High Toxic Hazard Electrical Hazard No Smoking Pressure Jets Do not let powercord come in contact with Disconnect Powercord Electric Shock Hazard water or other fluids. 100 HD...
Page 15
DO NOT VACUUM FLAMMABLE LIQUIDS DO NOT VACUUM EXPLOSIVE OR FLAMMABLE DUST Warning Sticker - 1 WARNING! SHAKE THE FILTER ONLY WHEN THE EXHAUSTER IS OFF Warning Sticker - 2 Filter Shaker Sticker MACHINE ORIENTATION Front Left Right Rear 100 HD...
F Owner’s personnel are not allowed to unpack the machine. NOTE F Before unpacking, carefully check the packaging for signs of damage. Report to authorized Roots Multiclean Ltd personnel immediately. F Upon unpacking, check for missing items or damaged parts. Report to authorized Roots Multiclean Ltd personnel immediately.
Page 17
READ, UNDERSTAND, and FOLLOW the safety messages. Serious injury or death may occur unless care is taken to follow the warnings and instruc ons stated in the safety messages. Always use good common sense to avoid hazards. 100 HD...
Page 18
Hold the handles tightly when going down or up a slope. Use industrial gloves for better grip (if required). Do not push or pull the machine when the castor wheel is locked. 100 HD...
Page 19
Empty the collection tank and clean the machine with a dry cloth. Wash the collection tank with fresh water if aggressive materials have been vacuumed. Store the machine in an indoor dry place. Lock the castor wheel. Close the suction inlet port with a cap (if equipped). 100 HD...
Page 20
(TOP) to protect the machine from overheating. In an event of the TOP being activated, the machine shuts off automatically. Wait for 30 seconds before restarting the machine. Note: Machine does not restart automatically after an TOP event. It has to be started manually. 100 HD...
Page 21
Wash the collection tank with fresh water. WARNING Clean the float with fresh water. Store the machine in an indoor dry place. DO NOT USE A HIGH PRESSURE JET TO CLEAN THE TANK. Lock the castor wheel. 100 HD...
Please contact your local Roots Multiclean Ltd. dealer. The CLEANING OR SERVICING THE MACHINE. people there will be glad to perform that work for you. Their well trained personnel and genuine Roots spare parts are at your disposal. DANGER In case of any inquiry or order for spare parts, please always quote the machine's serial number mentioned on the nameplate.
Page 23
Before locking the clamps to the top cover, shake the filter group unit by hand to correct any positional defects. WARNING DO NOT DISPOSE THE USED FILTER INTO THE ENVIRONMENT. THERE IS A RISK OF CONTAMINATING THE ENVIRONMENT. 100 HD...
Page 24
IMPORTANT: All electrical repairs should be done by Ensure that water does not enter any electrical part. authorized Roots Mul clean Ltd. service engineer ONLY. DO NOT use high pressure jet or steam cleaning equipments to clean the machine.
Page 25
Check the hose and if necessary replace Collection tank is full Empty tank Filter blocked Replace filter Machine does not work as intended Seals worn Clean the seals, is necessary replace them Check for leaks in the hose clamps, tighten if Air leak necessary 100 HD...
Page 26
û Do not operate the machine with bare foot, risk of electrical shock. û Do not use the filter shaker, while the machine is operating. û Do not do any kind of service, except Roots authorized representative. û Do not use the machine, if any abnormal sound is noticed in the suction turbine.