Download Print this page

Bosch ESHCK Installation Manual

Concentric vent / air intake kit for bosch models: gwh 715 es, gwh 2400 es, gwh 2700 es, evolution 500

Advertisement

Quick Links

Installation manual
Concentric Vent / Air Intake Kit
Stainless Steel
For Bosch Models: GWH 715 ES, GWH 2400 ES, GWH 2700 ES, Evolution 500
Part Number: ESHCK

Advertisement

loading

Summary of Contents for Bosch ESHCK

  • Page 1 Installation manual Concentric Vent / Air Intake Kit Stainless Steel For Bosch Models: GWH 715 ES, GWH 2400 ES, GWH 2700 ES, Evolution 500 Part Number: ESHCK...
  • Page 2 Installation Manual Stainless Steel - Concentric Vent / Air Intake Kit Installation Manual | 10.2009 Technical specifications are subject to change without prior notice...
  • Page 3 Installation Manual Table of Contents Introduction 1.1 Items included with Concentric vent kit 1.2 Venting material compatibility Installation Stainless Steel - Concentric Vent / Air Intake Kit Installation Manual | 10.2009 Technical specifications are subject to change without prior notice...
  • Page 4 It is not approved for through the roof, vertical terminations. The stainless 3" Tee 2SVSTTF03 FSTT3 9390TEE concentric vent kit is compatible with the following Bosch Terminal tankless water heaters: Table 1 Approved Tee Terminals • GWH 2400 ES The exhaust vent piping and tee terminal used with •...
  • Page 5: Installation

    Installation Manual 2 Installation Concentric Kit End Ensure all items listed in Section 1.1 are complete. Common installation practice is to determine the termination and exterior wall penetration point first. Next, design the venting/intake piping layout back to Exhaust the heater. Keep in mind, centrally locating the water vent pipe heater, whenever possible, is recommended to keep hot water distribution times even thoughout the structure.
  • Page 6 Installation Manual 10. Finish exhaust vent and combustion air piping installation back to the water heater. 11. Complete tankless water heater installation per the water heater’s installation manual (Fig. 6). Combustion 12" air pipe Exhaust vent pipe Combustion air openings Fig.
  • Page 7 Installation Manual Canadian installations U.S. installations Clearance above grade, veranda, porch, deck or balc . n i . n i . n i Clearance to permanently closed window Vertical clearance to ventilated soffit located above the vent terminator within a horizontal distance of 2 feet (61cm) from the center line of the terminator Clearance to unventilated soffit Clearance to outside corner...
  • Page 8 Bosch Thermotechnology Corporation 50 Wentworth Avenue Londonderry, NH 03053 Tel.: 800-642-3111 Fax: 603-584-1681 www.boschhotwater.com Bosch Thermotechnology Corporation reserves the right to make changes without notice due to continuing engineering and technological advances.