Page 1
AUTOMATIC SALT ELECTROLYSIS WATER TREATMENT SYSTEM STÉRILOR Sel Installation Instructions & User Guide Please read carefully and keep available for later use Version 11/2013 SR-12-163-4GB...
Page 3
Read it carefully before use in order to fully benefit from all of its functions. By using STERILOR Sel with a pH that is well regulated around 7, your pool's water will be perfectly disinfected.
CONTENTS 1. GENERAL RECOMMENDATIONS ........................ 6 2. PRESENTATION ............................7 General description ..........................7 2.1.1 Operation ..............................7 2.1.2 Supply ................................7 2.1.3 Front side of the box ...........................8 2.1.4 Lateral sides of the box ..........................9 3. INSTALLATION ............................9 3.1 Control box ..............................10 3.1.1 Location-attachments ..........................
Page 5
4.2 Production setting ............................15 4.2.1 Displaying and adjusting the production ....................15 4.2.2 Production percentage setting procedure ....................15 4.3 Automatic Operation or Forced Operation ..................... 16 4.3.1 Display – Operating the Forced operation ....................16 4.3.2 Forced Operation activation and deactivation procedure ..............16 4.4 Change in polarity ............................
When adding salt for the first time in the pool, or on each addition, the box and STERILOR Sel must be switched off for 24 hours, so that the salt is totally dissolved.
Hypochlorite (bleach), through salt water or during each subsequent addition, STERILOR electrolysis between 4 and 5 g/litre. Sel must be switched off for at least 24 hours, and total dissolution of the salt must be By maintaining a balanced pH around 7...
GENERAL PRESENTATION OF THE INSTALLATION OF A SWIMMING POOL TECHNICAL ROOM STERILOR Sel Filtration STEREDOX control dry contact Dry contact: Slow mode or Cover mode control ¾ salt electrolysis cell installed pH-liquid injection Filter Swimming Swimming pool pool inflow backflow...
Towards drains compressor heating, robot For any swimming pool covered with a The installation of STERILOR Sel on a polyester, paint or silico-marble liner, the swimming pool treated beforehand with installation of an EARTH is recommended (see PHMB...
It must operate at the same time as the filtration system. A box continuously connected to a separate socket will annul the guarantee. Before carrying out any electrical work on the box, this connection requires STERILOR Sel's power supply to be cut off at the filtration box.
Page 11
Single-phase filtration box: STERILOR Sel Clock Circuit breaker Contactor Auto Op. Forced Op. 380 V THREE-PHASE PUMP NEUTRAL EARTH Three-phase filtration box: STERILOR Sel Clock Circuit breaker Contactor Auto Op. Forced Op. MONO PUMP NEUTRAL EARTH...
Warning, the bypass valves must be open to plates. allow the water to pass through the electrolysis cell before STERILOR Sel is started Electrode connections Connect the cable provided for this purpose to the box, quick connectors.
Indication of the direction of flow: 3.4 Flow rate detector Flow rate STERILOR Sel is equipped with a blade flow detector detector. It detects the loss of flow before the electrolysis cell and stops the production (and therefore the electrolysis).
Weight of salt to be added in Kg = (5 – Warning, for temperatures below 15 °C, concentration of salt measured in g/l) x STERILOR Sel must be stopped. Swimming pool volume in m3 Example: The analysis detects 3 g/l of salt in...
The amount of Chlorine produced Reminder: Always switch off STERILOR Sel depends on the salt level, water temperature before adding salt. and quality, and the device's operating time, i.e. the filtration time.
Warning: production Leave the equipment to operate for a regulated in cover mode, you need to validate maximum of 24 hours, and carry out manual the position of the cover before setting (see analysis of the level of chlorine, in order to Chapter 4.5) to be certain to adjust the stop the shock chlorination if necessary and production percentage in normal mode, green...
4.5 Displaying device operating time and hours If there are no bubbles, the device is in STERILOR Sel indicates the time and is also chlorine regulation mode: equipped with an operating time counter. You need to hold down the + and – at the same time until the bubbles reappear.
It must be below 25 ppm, the ideal level being 15 ppm in order to be compatible with a redox measurement. STERILOR Sel is equipped with the Servocontrol of the chlorine production to the chlorine measurement servocontrol option, chlorine analyser (for example STÉREDOX):...
A regulation module inside the electrolyser means that there may be an offset in time between the signal emitted by the chlorine analyser (STÉREDOX) and the electrolyser's start (or stop) of production. Offset of 0 to 2 minutes. Measurement < Regulation threshold Case of STÉREDOX: "Regulation"...
As soon as the temperature of the pool water approximately 3 to 4 Volts. The same applies falls below 15 °C, stop STERILOR SEL. for counter-current pool motors. Therefore, Effectively, at these temperatures, Chlorine there is always a voltage of 3 to 8 volts in the production becomes practically zero, and the swimming pool's water.
It is important to provide one Earthing This installation of the Earthing sleeve sleeve for each pump existing on the filtration constitutes the earthing of the pool water and system. not the earthing of the equipment. Place an earthing rod in a location that retains You must connect the Earthing sleeve to humidity (in a watered rock, at the bottom of the Earthing rod using an Earthing braid with a...
Cut off the guarantee card opposite, without forgetting to make a copy before sending it duly completed to the following address: Product: STERILOR Sel AS POOL – STERILOR Company: The guarantee card below must be Address: ZAC de la Rouvellière F –...
GUARANTEE CARD Return a copy duly completed no later than 15 days after commissioning of the device to: AS POOL - STERILOR, ZAC La Rouvellière, 72700 SPAY Retailer's stamp: Purchaser's name and address: …………………………………………………... …………………………………………………... …………………………………………………... …………………………………………………... Purchase date: ……………………………...
Need help?
Do you have a question about the Sel and is the answer not in the manual?
Questions and answers