The H512 single channel modulator creates a new channel to add to
existing television channels. The H512 creates this new channel from a
video signal it receives via a single CAT-5 cable connected to one of its
)
C A T - 5
companion products such as the H721 camera or H110 wall plate. Any TV
e l v i a
c h a n n
1 H H R
s i n g l e
l H 5 1
c t o r (
m o d e
e l I n j e
e l P l u s
C h a n n
C h a n n
connected to the output via coax can receive the signal, when tuned to the
proper channel.
Typical Installation
350-079 Power Supply (Included).
Terminate cable with a
RJ-45 connector and
connect to the H512.
Use T568A Residential wiring pin out.
CAT-5 video
Single Channel Modulator
H512
To camera or Wallplate
(H721 typical)
Default Setting for H512
When not using baseband connectors insert all jumpers, (W1, W2, W3 &
W4 are installed at factory).
Optional Settings
To use baseband connectors as outputs when H512 receives video from
Cat-5 video source, Insert W2, W3, & W4, Remove W1.
To use baseband connectors as inputs when using the H512 as a stand
alone modulator. Insert W1 and remove W2, W3 & W4.
Coax Panel (Model H838HHR typical)
B
+Pwr
Televisions
Modulators
A
UP TO 8 TELEVISIONS
Things To Watch For:
No picture
... Check that the TV and the modulator are tuned to the same channel. For example,
if the modulator is broadcasting on UHF channel 16, make sure the TV is on UHF 16 rather than
CATV 16. UHF 16 and CATV 16 are at different frequencies. Also ... Make sure the H512 and
camera or wall plate are wired properly.
Weak ChannelPlus UHF channel
... If the TV has a separate UHF input, be sure that it is
connected.
Herringbone interference on modulator channel (diagonal lines):
channel number that is not completely vacant. Distant UHF stations may not be watchable, but
will cause interference if you try to create a new channel at the same frequency. Also, cable
companies often have extra signals where there should be none. Try moving the modulator
channel to another number. You may have to add a low pass filter to remove the cable company
noise. If the filter does not work, try adding a DC-block to remove common mode interference.
Herringbone interference on many channels, including modulated channel (disappears
when you remove the CATV/antenna feed)
strong signals. Often, you can cure the problem with a simple attenuator. Use a variable
attenuator and try to find a signal level where the interference just disappears. Sometimes, the
problem is one station is far stronger than the rest. In this case, attenuating all of the signals with
a simple attenuator may cause the desired stations to be weak (snowy). You must reduce the
strength of the only offending station. A common FM trap will help if the problem is a nearby FM
tower. If the problem is a nearby TV station, often the station management can provide suitable
filters.
Audio volume is low
... The left and right audio inputs are combined for monaural. For proper
audio level, both right and left inputs must be used. If you have a mono source, connect it to both
right and left inputs using an RCA 'Y' connector.
No color on ChannelPlus channels
... You may have chosen the incorrect cable standard. Not
all televisions can accommodate the 1.25MHz frequency difference between the H and I cable
standards. See the section on programming.
All manuals and user guides at all-guides.com
ChannelPlus Single Channel Modulator
Enter the new channel using
the
Program
push button.
Program
W1
W2
W3
W4
Output
Video Audio L
Audio R Power
Power the H512 last, make all
cable and CAT-5 connections
first.
Jumpers
High Headroom Amp w/IR Engine
CATV
/Ant
You may have chosen a
: The RF amplifier can be overloaded by abnormally
OpenHouse
tm
modules attach from the top
1
1) Hook from the top
2) Swing into place
3) Push button to lock
3
2
Programming the H512
Program the new channel using the
Program
H512. This new channel should be an unused channel. It should have no interference or
trace of a picture - just "snow". There must also be one unused channel both above and
below the selected channel to avoid interference. Below is a simple step by step example
of how to program a channel - cable channel
Press
program
button
1
time
Press
program
button
2
more times
Press
program
button
10
more times
(press 10 to
enter a 'zero')
Cable HRC and IRC considerations:
Most cable services use standard or IRC frequency assignments. This is the default for the
H512. However, if the cable services use HRC or the TV appears to search for the "created
channel", program the channel injector for HRC.
For HRC enter a 98. Reset to IRC by entering 99.
Entries 98 and 99 are for setting HRC or IRC only. They do not change the channel number.
CAT-5 Cable Length Limitations:
The length of the CAT-5 cable that runs between the H512 and the camera or wall plate is limited.
See the individual camera or wall plate manuals for these CAT-5 cable run limitations.
Specifications: typical @ 25 C ± 5 C
O
video
Inputs
(Ports)
video termination
(switch selectable)
audio
differential gain
Video
performance
differential phase
signal/noise
standard
RF output
channel ranges
output level
IM distortion
alternate channel
model number
Power supply
output current
output voltage
input power
DECLARATION OF CONFORMITY
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO
THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
Installation requirements:
FCC classifies this product under part 15 of its rules as a "television interface device".
Systems designed using television interface devices have the following legal requirements:
1) The modulated channel signal strength may not exceed 15.56dBmV at any television.
Federal Regulation 47CFR15.115(b)(1)(i).
2) If an antenna is used in the system, the modulated channel signal strength may not exceed -
51dBmV at the antenna input port.
Federal Regulation 47CFR15.115(c)(4).
For the Installer:
Any system you design must comply with these regulations. As the installer, you are responsible.
The H512 has the necessary characteristics to comply with the above requirements as designed
without additional accessories.
Telephone Master Hub (4 lines x 6 phones)
Telephone Master Hub (4 lines x 6 phones)
ChannelPlus model H616
From
From
Expansion
Expansion
Telephones
Telephones
Telco
Telco
Ports
Ports
R
R
RJ31X
RJ31X
4
T
T
3
R
R
T
T
R
R
2
T
T
Out
R
R
1
T
T
push button to enter channel digits into the
120
:
Wait for
power
LED
(ready for next number.)
Wait for
power
LED
(ready for next number.)
LED comes back on when
done. If an incorrect
channel is entered, LED
will flash quickly and
return to the previous
setting.
O
1 Vp-p @ 75
75
in normal mode (NORM)
>1M
in loop through mode (LOOP)
1 V rms @ 47k
L & R inputs combined for monaural
4%
<4º
55 dB
UHF
CATV
65-125(excluding 95-99)
14-64
+25 dBmV (+85dBuV)
-60 dBC
-45dBC @ 12MHz
350-079
600mA
15 VDC
105-125 VAC
Need help?
Do you have a question about the H512 and is the answer not in the manual?
Questions and answers