Page 1
项目 校对项 库 文件名 1.版面尺寸 2.材质标注 3.物料编码 4.颜色标注 5.客户型号 USER MANUAL Ultrasonic Humidifier 6.产品名称 Model: ME-F800W 7.重量标注 Rated voltage: 120V Rated power: 24W Frequency: 60Hz 8.电压功率 9.说明书装 订要求 10.警语/认证 标志高度 Warning Notice: Before using this product, please read this manual carefully and keep it for 11.档位、...
Page 2
USER MANUAL Ultrasonic Humidifier Model: ME-F800W Rated voltage: 120V Rated power: 24W Frequency: 60Hz Warning Notice: Before using this product, please read this manual carefully and keep it for future reference. The design and specifications are subject to change without prior notice for product improvement.
READ AND SAVE THESE INSTRUCTIONS Read This Manual Inside you’ll find many helpful hints on how to use and maintain your appliance properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your appliance. You’ll find many answers to common problems in the troubleshooting tips - you should be able to fix most of them quickly before calling customer service.
Page 4
IMPORTANT INSTRUCTIONS • Do not replace the power cord without authorization, or connect the power cord halfway or use other appliances in parallel; • Do not place the appliance near water source; • Do not disassemble, modify or repair internal parts without authorization; •...
• Please use the purified water below 104°F(Do not use distilled water). ASSEMBLY This humidifier is pre-assembled in factory. SPECIFICATIONS NOTICE ME-F800W • The following are the design parameters of the measured parameters are subject to the product; • The humidification amount will vary, depending on the temperature and humidity in the room.
PARTS AND FEATURES NOTICE • The pictures of the Manual are for reference only, and the actual product in the packing box shall prevail • The product appearance and function vary with the model; Please be subject to the real product, with optional reading of the respective function description.
Page 7
INSTRUCTION FOR USE Two methods for water filing Method A Fill the water tank directly through the main unit cover.Please use purified water.Please do not add the water in the atomization outlet. Atomization Outlet Main Unit Cover Method B Lift the main unit of the humidifier up and fill purified water directly from top of the water tank.
Page 8
2. In the on/idle state, press and hold 3 seconds till hear “be- ep”, the WIFI signal on the screen will blink and enter the On/Off CARRO HOME APP connection Mode. Under working conditions, the humidity and atomization amount can be set to three levels (small, medium and Atomization large).
Humidity setting On/Off, this On/Off button for preventing mistakenly touching. The default humidity setting is 60%RH. Humidity On/Off The indicator light is on when the humidifier is shortage of water. Water shortage indicator light When connecting to the network, the indicator light is on. WiFi indicator light 01 small atomization amount...
Page 10
Clean the outside part Lift the main unit up in Clean the outside part of the machine. the direction of the arrow. of the machine. Cleaning the outer casing Wipe and clean the surface of the whole machine with a slightly damp soft cloth.
Page 11
Cleaning the inside & outside of the mist guiding tube,and the atomizing head 1. Rotate counterclockwise to unscrew connecting hose of the main unit and the atomizing head as shown in Fig 1. 2. Hold the main unit with one hand, press the spring switch of the mist guidi- ng tube with the other hand at the same time as shown in Fig 2, and remove the main unit in Fig 3.
Page 12
NOTICE The foam of the float in Fig 7 is important part of atomizing head assembly, DO NOT mistakenly discard it as part of the packaging. Mist tube assembly installation Install the atomizing head Put the main unit on the table, on the float assembly.
Page 13
APP Control Connection: 1.First download the free Carro Home app from the App Store or Google Play or scan the QR Code as below. Note: This humidifier needs to use 2.4Ghz wifi to work when you connecting the device, and after connecting it can use the 5Ghz or 2.4Ghz.
Page 14
SERVICE GUIDE Fault Handling NOTICE • If the humidifier does not work properly after the following suggestions, please contact the customer service center or local service station. PROBLEM CAUSE SOLUTION The power plug is not plugged well The power plug is plugged well The humidifier does not There is no water in the water tank The water is added to the tank...
) • Any humidifier outside of the contiguous 48 states • Any claim made outside of the warranty period QUESTIONS? CONTACT US. Carro USA Inc. 1431 S.Baker Ave.Ontario CA91761 Tel:888-253-2374 www.carrohome.com |cs@carrohome.com Page 14 ...
Page 16
FCC Statement: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Need help?
Do you have a question about the ME-F800W and is the answer not in the manual?