Laser 4212 Instructions Manual

Cam belt tensioner gauge

Advertisement

Quick Links

4212

Advertisement

loading

Summary of Contents for Laser 4212

  • Page 1 4212...
  • Page 2 Instructions Cam Belt Tensioner Gauge Measure the tension on most cam belts...
  • Page 3 C C o o n n t t e e n n t t s s Introduction Page 3 Principle of operation Page 4 Controls and indicators Page 4 Precautions Page 5 Operation Page 5 Getting the best results Page 8 Menus Page 8 Calibration...
  • Page 4 Principle of operation The measuring head is placed on the belt and the clamp is tightened using the clamping knob. This deflects the belt through a known angle defined by the anvil and the fixed pillars. A load cell attached to the clamp measures the force required to deflect the belt, which is proportional to the tension in the belt.
  • Page 5 If the LED’s do not flash, then the batteries may be flat or incorrectly fitted. The message ‘LASER' will appear for one second. This is followed by the message ‘DISPLAY CONTRAST’ then the prompt ‘LIGHT / DARK / OK...
  • Page 6 The contrast should not require further adjustment unless there is a large change in temperature, or the batteries are nearing the end of their life. If no display is visible, check that the contrast has not been set too low. After setting the contrast, the unit checks if the measuring head is connected.
  • Page 7 17. When the tension is correct, press the key to confirm the setting. After setting the high limit, the message ‘LOW LIMIT: 200’ will appear. This shows the currently set low limit for the tension measurement. The low limit is displayed and set in the same way as the high limit.
  • Page 8 25. If at any time whilst tightening the clamp, the three LED’s illuminate, the beeper sounds continuously and the message ‘WARNING-OVERLOAD’ appears on the display, stop tightening the clamp immediately. If the load exceeds 850 Newtons or the equivalent, the message ‘HEAD DAMAGED’...
  • Page 9: Display Contrast

    DISPLAY CONTRAST RESTORE DEFAULTS TURN BEEPER ON [OFF] TURN LEDS ON [OFF] CALIBRATION Press the key to select the required option. This performs the menu operation and returns to the menu header screen, except for the calibration procedure, which had several steps. To exit the menus without making a selection, press the ‘Menu’...
  • Page 10 This will not prevent use of the instrument, but calibration should be carried out as soon as possible. FAILURE TO RE-CALIBRATE THE UNIT WHEN REQUIRED WILL RESULT IN INCORRECT VALUES BEING DISPLAYED. THIS WILL RESULT IN INCORRECT TENSION BEING APPLIED TO A BELT, AND THE BELT COULD SUBSEQUENTLY FAIL.
  • Page 11 Specification Belt width Up to 36mm Measurement range 0 – 750 Newtons 0 to 77 Kilograms 0 to 170 Pounds 0 to 12.0 Ford/Lowener/Vauxhall 0 to 53 0 to 14.5 Peiseler/Seat/VAG/Volvo 0 to 114 Seem Overload warning Newtons Maximum load Newtons Measurement resolution +/- 10 (or at least 1 sig.