Download Print this page
Koolatron MK12 Manual
Hide thumbs Also See for MK12:

Advertisement

Quick Links

2014-5825
2015-01-13
Constructed with durable outdoor furniture quality plastic
READ THE LABEL AND ENCLOSED INSTRUCTIONS BEFORE USING
CAPTURES MOSQUITOES
An attractant for mosquitoes!
NO TOOLS NEEDED!
Assembles in less than 60 seconds
Uses 9 kg (20 lb) Propane Tank (not included)
Propane lasts 4 to 6 weeks
Weatherproof Design
Piezo push button starter
Light weight
Wheels for easy movability
One Year Limited Warranty
DOMESTIC
KEEP OUT OF REACH OF CHILDREN
REG. NO. 28460 PCPA
KOOLATRON INC.
1-800-265-8456
139 Copernicus Blvd.
Brantford, ON N3P 1N4
Canada
1

Advertisement

loading

Summary of Contents for Koolatron MK12

  • Page 1 Light weight Wheels for easy movability One Year Limited Warranty DOMESTIC KEEP OUT OF REACH OF CHILDREN READ THE LABEL AND ENCLOSED INSTRUCTIONS BEFORE USING REG. NO. 28460 PCPA KOOLATRON INC. 1-800-265-8456 139 Copernicus Blvd. Brantford, ON N3P 1N4 Canada...
  • Page 2 Listed DIRECTIONS FOR USE INSIDE Visit us on the web: www.koolatron.com For info call: 1-800-265-8456 KOOLATRON INC. 139 Copernicus Blvd., Brantford, ON N3P 1N4 Canada Warehouse: 4330 Commerce Dr., Batavia, NY 14020-4102 USA...
  • Page 3 The MK 12 Guradian Mosquito Trap is on duty 24 hours a day and requires very little up-keep. Simply empty the contents of the capture chamber (where the mosquitoes collect) and refill the propane periodically. Vacuum Fan Pulls Mosquitoes in and Traps them Exhaust Holes Release CO into the Wind Catch Cup Removes and Cleans Easily...
  • Page 4: Directions For Use

    REG. NO. 28460 PCPA KOOLATRON INC. 139 Copernicus Blvd., Brantford, ON N3P 1N4 Canada Warehouse: 4330 Commerce Dr., Batavia, NY 14020-4102 USA Questions? Call 1.800.265.8456 ©2006 Koolatron Inc. All rights reserved. All specifications are subject to change without notice. REVINSTMK11-1206...
  • Page 5 The pressure regulator and hose assembly supplied with the MK 12Guardian Mosquito Trap must be used for the connection to the propane tank. The maximum inlet gas supply is less than 30 SCFH. Replacement pressure regulator and hose assemblies must be provided by Koolatron Inc.
  • Page 6 1. Do not store or use gasoline or any other flammable vapours and liquids in the vicinity of the MK12 Guardian Mosquito Trap or any other appliance. 2. The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1-1998 for US and with the CANI-B149 for Canada.
  • Page 7 ASSEMBLY Step 1: Assemble the support column to the base Place the base on a flat surface. Insert the support column with the slotted side down as shown. Press in firmly. Step 2: Attach the Burner Unit to the top of the support column Attach the burner unit to the top of the support column as shown.
  • Page 8 Step 4: Attach the trap body to the Upper Body Support Column Insert the tab on the trap body to the slots on the top of the Upper Body Support Column as shown. Press in firmly. Step 5: Select the location where the MK 12 Guardian Mosquito Trap will be installed and hammer the stakes in the ground to properly secure it.
  • Page 9 ATTACHING THE PROPANE TANK Step 6: Attach the power adapter A. Hang the power adapter on the back of the base as shown. B. Plug the adapter end into the socket on the underside of the trap body as shown. Step 7: Attach the Propane Tank to the Base.
  • Page 10 MK12 Guardian Mosquito Trap WHERE TO PLACE THE MK 12 GUARDIAN MOSQUITO TRAP Many species of mosquitoes have an adult life span that lasts about two weeks. Approximately 3,000 species of mosquitoes have been identified world-wide. Both male and female mosquitoes feed on plant nectar, but only the female requires a blood meal.
  • Page 11 MK12 Guardian Mosquito Trap HOW THE MK 12 GUARDIAN MOSQUITO TRAP WORKS The MK 12 Guardian Mosquito Trap utilizes the documented attractiveness of carbon dioxide ), moisture, body temperature (thermal imaging), colour, shape and airflow in an effective design that captures and kills mosquitoes. Similar traps have been in use for years by universities, state monitoring programs and researchers around the world.
  • Page 12 STARTING THE MK 12 GUARDIAN MOSTQUITO TRAP Step 1: Open the gas valve on the tank to the full open position by turning it counterclockwise until the knob stops rotating Step 2: Press and hold the safety button. While looking into the center of the burner unit through the window, press the red button until a blue flame appears inside the window directly in front of you.
  • Page 13: Operation

    OPERATION 1. Plug in the adapter’s power cord to an approved "Outdoor Use" extension cord and in accordance with the safety instructions on page 12. 2. Plug the adapter end into the socket on the underside of the trap body as shown. 3.
  • Page 14 Do Not Spray with or immerse any part in water. 7. Replacement parts (Regulator with hose, Catch Cup, Ground Stakes) are available from Koolatron Inc. 8. Store the MK 12 Guardian Mosquito Trap in a cool dry place when not in use and AWAY FROM ANY CHEMICALS.
  • Page 15 MK12 Guardian Mosquito Trap SHUTTING OFF THE MK 12 GUARDIAN MOSQUITO TRAP Step 1: Close the gas valve on the propane tank by turning it clockwise. Step 2: Look through the window on the side of the burner unit and verify that the flame has gone out. It may...
  • Page 16 ACCESSORIES PROPANE TANK COVER Item#: MKTCoverP • Made of durable outdoor cotton-based, weather-resistant material • Machine washable in cold water, looks great! • Designed with sewn-in velcro strips for quick and easy wrap-around installation • Fits any standard 9 kg (20 lb.) propane tank •...
  • Page 17 24. The pressure regulator and hose assembly supplied with the MK 12 Guardian Mosquito Trap must be used for connection to the LP-Gas cylinder. Replacement pressure regulators and hose assemblies must be purchased from Koolatron Inc.
  • Page 18: Warranty

    WARRANTY...
  • Page 19 ****************************** This label transcript service is offered by the Pest Management Regulatory Agency to provide efficient searching for label information. This service and this information do not replace the official hard-copy label. The PMRA does not provide any guarantee or assurance that the information obtained through this service is accurate, current or correct, and is therefore not liable for any loss resulting, directly or indirectly, from reliance upon this service.