5.
OPERATION
5.1
Dual Voltage Models XRC55 & XRC90. Before operating the
unit ensure that the correct voltage has been selected.
5.2
Continuous operation in manual mode.
5.2.1
Connect the unit to the mains power supply.
5.2.2
Switch the unit on by moving the on/off switch to the ‘I’ position at
which point the switch should illuminate. After a few minutes the
green LED on the control panel will illuminate indicating that the
compressor has started. In this mode the unit will dry the air
continuously until the unit is switched off again.
5.2.3
To switch the unit off move the on/off switch to the ‘O’ position.
5.3
Automatic operation using a remote hygrostat. (Optional)
5.3.1
Connect the unit to the mains power supply.
5.3.2
Connect the hygrostat lead to the jack socket on the units control
panel. Switch the unit on. After a few minutes the green LED will
illuminate and the compressor will start to rotate. Set the desired
level of humidity on the hygrostat. If the general humidity is
higher than the preset value the unit will start to operate. When
the humidity has reached the preset value the compressor will be
switched off automatically but the fan will continue to operate.
When the air humidity increases above the preset value the
compressor will cut in again. This automatic cycling will continue
until the unit is switched off.
5.4
Electronic control.
5.4.1
Each dehumidifier is equiped with an electronic control
unit with related LED display panel which can be seen on the
rear of the dehumidifier. The functions of the LEDs are as
follows, (see fig.6).
5.4.2
ŒORANGE LED. The room temperature is too low or the unit
is in defrost mode.
5.4.3
RED LED. The room temperature is too high or a reduction
of air flow has occurred. Check filter and remove obstructions to
air flow if required. Check that the fan is rotating.
5.4.4
ŽYELLOW LED. The water tank is full. Empty tank or check pump.
5.4.5
GREEN LED. The compressor is running.
fig. 6
6.
MAINTAINANCE
6.1
Unplug the unit from the power supply before carrying out any maintenance or service.
6.2
Cleaning the filter. To maintain the efficiency of the unit wash the filter in luke warm water on a regular basis.
6.3
Cleaning the unit. Clean the unit at least once a year. Remove air filter, remove front and rear panels to gain access to inner
parts. Clean inner parts using compressed air paying particular attention to the condenser, evaporator and water drainage tray.
Declaration of Conformity
Dehumidifiers
Models XRC25, 40, 50 & 90
73/232/EEC Low Voltage Directive
89/336/EEC EMC Directive
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product. WARRANTY: Guarantee is 12 months from purchase date, proof
of which will be required for any claim. INFORMATION: Call us for a copy of our latest catalogue on 01284 757525 and leave your full name
and address including your postcode.
We, the sole importer into the UK, declare that the products listed below are in conformity withthe following standards and directives.
Signed by Mark Sweetman
Sole UK Distributor
Sealey Group,
Bury St. Edmunds, Suffolk.
The construction files for these products are held by the Manufacturer and may
be inspected, by a national authority, upon request to Jack Sealey Ltd.
For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Tools.
01284 757500
01284 703534
14th April 2003
www.sealey.co.uk
9A>
sales@sealey.co.uk
email
XRC25,40,55,90 - 1 - 060503