2.
INTRODUCTION & SPECIFICATIONS
The XRC commercial/industrial dehumidfier range is designed to remove moisture from the air in high humidity environments such as cellars,
kitchens, bathrooms etc. The units are designed for continuous operation either manually or automatically if connected to an optional hygrostat
sensor. The internal cooling units use the more environmentally friendly R407C cooling gas. All units have an air filtering system, electronic
control, a defrost system for compressor protection, and an automatic stop when the water collection tank is full. The units are easy to move
and robustly constructed.
MODEL NO
. .Units of measurement/spec. .
Electrical power . . . . . . . . . . .W . . . . . . . . . . . . . 650 . . . . . . . . .800 . . . . . . . .831 . . . . . . . .1205
Max. current . . . . . . . . . . . . . .A . . . . . . . . . . . . . .3 . . . . . . . . . . .4 . . . . . . . . . .5 . . . . . . . . . .7
Drying capacity . . .30
C / 80%RH (L / 24H) . . . . .23 . . . . . . . . . .42 . . . . . . . . .53 . . . . . . . . .88
O
. . . . . . . . . . . . . .27
C / 60%RH (L / 24H) . . . . .11 . . . . . . . . . .27 . . . . . . . . .37 . . . . . . . . .54
O
. . . . . . . . . . . . . .12
C / 70%RH (L / 24H) . . . . .5 . . . . . . . . . . .7 . . . . . . . . . .18 . . . . . . . . .22
O
Working range (Humidity) . . .%. . . . . . . . . . . .40 -100 . . . . . .40 -100 . . . . .40 -100 . . . . .40 -100
Working range (Temperature)
Air flow . . . . . . . . . . . . . . . .m
Cooling gas type . . . . . . . . .Gas . . . . . . . . . . .R407C . . . . . .R407C . . . . . .R407C . . . . . .R407C
Cooling gas mass . . . . . . . . .(g) . . . . . . . . . . . . .350 . . . . . . . . .500 . . . . . . . .525 . . . . . . . .700
Compressor . . . . . . . . . . . . . . . . . . . . . . . . .Reciprocating . . . .Rotary . . . . . .Rotary . . . . . .Rotary
Container full LED . . . . . . . . . . . . . . . . . . . . . . . .Yes . . . . . . . . .Yes . . . . . . . .Yes . . . . . . . .Yes
Compressor protection . . . . . . . . . . . . . . . . . . . . .Yes . . . . . . . . .Yes . . . . . . . .Yes . . . . . . . .Yes
Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Yes . . . . . . . . .Yes . . . . . . . .Yes . . . . . . . .Yes
Tank capacity . . . . . . . . . . .Litres . . . . . . . . . . . .10 . . . . . . . . . .10 . . . . . . . . .10 . . . . . . . . .10
Weight . . . . . . . . . . . . . . . . .Kg . . . . . . . . . . . . .34 . . . . . . . . . .51 . . . . . . . . .57 . . . . . . . . .63
Dimensions . . . . . . . . . . . . .mm . . . . . . . . .455x370x635 .540x460x860 .970x670x650 .985x700x700
3.
TRANSPORT & ASSEMBLY
3.1
Transit. The unit should be transported in a vertical position or inclined on the handle
side. If it has been transported in a horizontal position allow the unit to stand in the
vertical position for about one hour to allow the lubrication to be rebalanced.
3.2
Check that the unit has not been damaged in any way and that all parts are present. If
there are any problems contact your local Sealey dealer.
3.3
Packaging. Packaging materials such as cartons, polythene bags etc should not be
left within the reach of children as such items could be dangerous to them. Dispose of
all packaging materials in accordance with local authority requirements.
3.4
Assembly. Assemble the main handle to the body of the unit as shown in fig.1 using
the fixing screws provided.
4.
INSTALLATION
4.1
It is important that the air inlet and air outlet remain unobstructed at all times.
4.2
The following minimum safety distances are recommended between the unit and
walls or objects.
4.3
Ideally the unit should be installed in the centre of the room to guarantee the best
possible air circulation.
4.4
DO NOT install the unit near heat sources. Keep windows and doors closed whilst the
unit is operating.
4.5
Dual voltage models (XRC55 & 90). The dual voltage models are designed to run off
either a 230V 50Hz supply or a 110V 50Hz supply. To select the required voltage do
the following:
Ÿ
Remove the two fixing screws holding the voltage selector cover plate.
Ÿ
Ÿ
Move the selector switch to the required voltage.
Ÿ
4.6
Water drain. Drained water can be collected and eliminated in 2 ways:
A) Using the tank supplied as shown in fig.2. The tank must be emptied when the yelow ‘tank full’ LED lights up. Switch the unit off
before emptying the tank and disconnect the mains plug. Remove the tank carefully to avoid spills and empty it. Slide the tank back
into the unit ensuring that the level sensor is correctly placed within the tank.
NOTE: When the dehumidifier is switched off and then restarted, the compressor will not start to run immediately but will cut in again
after some minutes. This waiting time protects the compressor from repeated starts at short intervals.
B) Water may be removed by connecting a plastic hose with an internal diameter of 14mm to the hose holder in the drain
compartment. ( Plastic hose not supplied.) See fig.3.
Special attention should be paid not to raise the outlet of the hose over the drain level of the unit. (Max height 1ft, see fig.4) Failure to
do this will result in water spillage and flooding of the unit.
4.7
Connection of a Hygrostat. A hygrostat control is also available as an optional accessory. This enables the unit to function automatically.
The remote hygrostsat will be located near the air inlet and is connected to the unit via a jack plug on the units control panel
XRC25,40,55,90 - 1 - 060503
XRC25 . . . . .XRC40 . . . .XRC55 . . . .XRC90
C. . . . . . . . . . . . .5 - 30 . . . . . . .5 - 30 . . . . . . .5 - 30 . . . . . . .5 - 30
O
/h . . . . . . . . . . . .350 . . . . . . . . .500 . . . . . . . .600 . . . . . . . .800
3
Ÿ
Minimum distance from air inlet - 0.6m.
Ÿ
Ÿ
Minimum distance from air outlet - 3.0m.
Ÿ
Ÿ
Reverse the cover plate and screw it back into position.
Ÿ
fig. 4
fig.1
fig. 2
fig. 3