L1
L2
L3
L1 L2 L3
1)
L1 L2 L3
2)
3
+
i
3
V
W
U
M
3
1)
Circuit breaker
VAU 7.5/3 → C 20
VAU 11-22/3 → C 32
2)
Frequency converter (FC): follow additional instructions
3)
Operation only permitted with temperature monitoring
Motor Data:
Voltage:
330 V
Cos φ:
0.9
Rated current:
20.5 A
Rated speed:
20.250 min
Rated frequency:
340 Hz
Rated power:
9,500 W
Additional parameters for the frequency converter setting:
Current Limitations:
Speed Limitations:
Motor Thermal Protection:
Additional Parameters:
7
2Nm
8
1
5
2 4
3
: L1
1
: L2
2
: L3
3
: PE
4
: Motor thermal
5
protection (PTC)
3)
8
-1
The motor current limit must be set to 26 A and be activated I2* t-Limit (motor
overload monitoring) must be adapted to the motor current (26 A) and activated
Minimum frequency: 10 Hz or equivalent corresponding speed
Maximum frequency: 400 Hz or equivalent corresponding speed
Motor-PTC must be connected and monitoring must be enabled
Motor-PTC is only basic isolated
0.08 Ω
Stator resistance:
Stator inductance:
0.27 mH
Main inductance:
12.1 mH
Rotor inductance:
0.28 mH
Cooling fan
terminal
W2 U2 V2
3~
U1 V1 W1
L1
L2 L3
W2 U2 V2
3~
U1 V1 W1
L1
L2 L3
W2 U2 V2
1~ ( )
U1 V1 W1
L
N
R V 2 . 19 4 4/1 0
U1 (T1) = black
V1 (T2) = blue
W1 (T3) = brown
U2 (T4) = green
V2 (T5) = white
W2 (T6) = yellow
50 Hz
U
I (max.)
P (max)
346-525V
0.22A
91W
60 Hz
U
I (max.)
P (max)
380-575V
0.18A
87W
50 Hz
U
I (max.)
P (max)
200-303V
0.37A
91W
60 Hz
U
I (max.)
P (max)
220-332V
0.31A
87W
50 Hz
U
I (max.)
P (max)
220-277V
0.28A
66W
60 Hz
U
I (max.)
P (max)
220-277V
0.30A
75W
I 3