INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY
TO PERSONS IMPORTANT
SAFETY INSTRUCTIONS
Lighted lamp is HOT!
WARNING - To reduce the risk of FIRE OR INJURY TO
PERSONS:
Turn off/unplug and allow to cool before replacing
lamp.
Lamp gets HOT quickly! Contact only switch/plug
when turning on.
Do not touch hot lens, guard, or enclosure (see
diagram/picture).
Keep lamp away from materials that may burn.
Do no touch the lamp at any time. Use a soft cloth. Oil
from skin may damage lamp.
Do not operate the luminaire fitting with a missing or
damaged shield.
SAVE THESE INSTRUCTIONS
Proper soil preparation is recommended before installation. See the DIG-IT guide at www.bklighting.com/dig-it for more
RE1 Option - GFI
RE2 Option - GFI & USB
RE3 Option - RJ45 Jack
CONCRETE INSTALLATION ONLY
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION
B-K LIGHTING
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR
SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
Warning
High Voltage
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL
Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the
National Electrical Code, Canadian Electrical Code, and all
Local and Provincial Codes.
Follow product label information and instructions.
Qualified Personnel must perform all servicing or relamping
of this product.
Before wiring to power supply and during servicing or
relamping, turn off power at fuse or circuit breaker before
service.
The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause
an unsafe condition. The use of damaged components may
cause an unsafe condition and void product warranty.
IMPORTANT LISTINGS AND CERTIFICATIONS
· Suitable for wet locations
Machined
Aluminum
Housing
Cover with Captive
Tamper Resistant
Screw
INSTRUCTIONS
40429 Brickyard Drive • Madera, CA 93636 • USA
3/32", 1/8" & 7/64" Allen Wrench
TOOLS
NEEDED:
Waterproof Wire Connectors
Epoxy (Supplied)
Sleeve or Wedge Anchors for Concrete (1/4" Dia. Min.)
Data Cable (RE3 Option Only)
By Others
SAFETY AND INSTALLATION INSTRUCTIONS
nformation.
Grade Label
Epoxy
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
Union Bollard
Do not block light emanating from product in whole or
part, as this may cause an unsafe condition.
Never operate the fixture with missing or damaged lens.
Lens must be cleaned on regular basis.
Entire fixture may become extremely hot. Do not touch hot
lens or fixture body. Do not touch the lamp at any time.
Use a clean, dry, soft cloth to handle the lamp. Oil from
skin may damage the lamp and cause it to rupture.
Replace lamp only with correct wattage and type of lamp
marked on fixture label.
All gaskets, o-rings and sealing surfaces must be kept
clean during installation and service; failure to do this may
cause an unsafe condition and void product warranty.
Machined Base
Steel Plate
Tenon
PVC
Primary 3/4"
Conduit Connectors
RELEASED DATE
REFERENCE NUMBER
06/27/2021
INS-2846-00

Advertisement

loading

Summary of Contents for B-K lighting Union Bollard

  • Page 1 • info@bklighting.com THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
  • Page 2: Installation Of Base

    Union Bollard Installation Instructions PVC HOUSING MUST BE INSTALLED AS PER GRADE LABEL. HOUSING IS LABELED AT GRADE LEVEL. HOUSING INSTALLED BELOW GRADE WILL VOID WARRANTY INSTALLATION OF PVC MOUNTING Concrete Concret Pea Gravel Finished Grade Concrete Finished grade Finished Grade...
  • Page 3 Union Bollard Installation Instructions Mount base and plate to concrete using mounting 8. Tighten four (4) #10-32 screws in base 9. Seal base and plate as per NEC. Continue with holes drilled previously (mounting hardware by using a 3/32” allen wrench to secure to installation of receptacle option chosen.
  • Page 4 Union Bollard Installation Instructions INSTALLATION OF RECEPTACLE (RE1 & RE2 Option) Attach ground from branch circuit to screw on 2. Attach receptacle to installed anchor base 3. Secure receptacle cover by tightening #6-32 anchor base. Place connectors inside receptacle. with (4) #10-32 stainless steel countersunk set screw using a 7/64”...
  • Page 5 Union Bollard Installation Instructions 6. Attach in-use receptacle to installed anchor Receptacle cover has captive #6-32 screw. base and plate with (4) #10-32 stainless steel cap Secure receptacle by tightening captive screws at the base using a 1/8” allen wrench.