I.Overview HZIR-1000 SF6 infrared quantitative detector adopts high-speed embedded MCU, Chinese touch man-machine interface, and the operation is simple and clear. The sensor is imported from Germany based on the technical principle of the dual-wave non-dispersive infrared spectrometer (NDIR). The complete hardware and software design of the SF6 gas leak infrared leak detector provides reliable and high-precision performance and maintenance-free features.
III. Main functions and features (1) The principle of infrared dual spectrum is used to replace imported infrared detectors; (2) Unique anti-stripping wristband, which can be operated with one hand. (3) The first flashlight function, which is convenient for on-site inspection in the case of insufficient light.
Page 6
Figure 2 After 5 seconds, the display backlight will automatically go out, the left indicator will be on (long on), and the side indicator will flash, this is the standby state. (1) Shortcut key operationWhen the interface shown in Figure 2 appears after power-on, press the measurement key and the interface shown in Figure 3 appears: Figure 3 Automatically delay preheating for 90 seconds (countdown, the sensor itself requires.
Page 7
Figure 4 The ">,<" symbols appear on the interface to change alternately, indicating that it is in the measurement state and the measurement can be performed. After a set of data is measured, press the measurement button, and the internal air pump will stop. If you need to measure the next data, press Measure button, the air pump inside the machine starts and starts measuring again, and it can cycle like this.
Page 8
Figure 5 The user operates on the off touch key as needed, the backlight will automatically go out after 5 seconds, and the red indicator light on the right side will flash, indicating the standby state, and the interface in Figure 2 will be restored after touching the screen. Touch the measurement key: measurement can be performed.
Page 9
Touch the backlight key: you can change the brightness of the backlight, there are five adjustments (note! Not in the measurement state, the shortcut save key, you can also change the backlight brightness) after the backlight is automatically turned off, press the shortcut key and any part of the screen can restore the backlight In the measurement state, the backlight will not be completely turned off, only the brightness will be reduced.
V. Matters needing attention (1) This equipment performs operational function verification every two years. (2) In order to ensure the personal safety of the operator and the safety of the equipment, the terms in the instructions for use must be observed. (3) This equipment is a special tool for detecting SF6 gas.